Eugenia Baena

Dr. Eugenia Baena

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2020 in Marine Drugs
Verified
Journal Article
Open access
PDF file
Eugenia BaenaEugenia Baena
Eugenia Baena
SCSandra Ribeiro De Barros Cunha
Sandra Ribeiro De Barros Cunha
Tatjana MaravicTatjana Maravic
Tatjana Maravic
ALLEGRA COMBAALLEGRA COMBA
ALLEGRA COMBA
FPFederica Paganelli
Federica Paganelli
Annalisa MazzoniAnnalisa Mazzoni
Annalisa Mazzoni
The aim of the present study was to evaluate the effect of 0.1% chitosan (Ch) solution as an additional primer on the mechanical durability and enzymatic activity on dentine using an etch-and-rinse (E&R) adhesive and a universal self-etch (SE) adhesive. Microtensile bond strength and interfacial nanoleakage expression of the bonded interfaces for all adhesives (with or without pretreatment with 0.1% Ch solution for 1 min and air-dried for 5 s) were analyzed immediately and after 10,000 thermocycles. Zymograms of protein extracts from human dentine powder incubated with Optibond FL and Scotchbond Universal on untreated or Ch-treated dentine were obtained to examine dentine matrix metalloproteinase (MMP) activities. The use of 0.1% Ch solution as an additional primer in conjunction with the E&R or SE adhesive did not appear to have influenced the immediate bond strength (T0) or bond strength after thermocycling (T1). Zymography showed a reduction in MMP activities only for mineralized and demineralized dentine powder after the application of Ch. Application of 0.1% Ch solution does not increase the longevity of resin–dentine bonds. Nonetheless, the procedure appears to be proficient in reducing dentine MMP activities within groups without adhesive treatments. Further studies are required to comprehend the cross-linking of Ch with dentine collagen.

23 July 2020 in Odontology
Verified
Journal Article
Open access
PDF file
JSJoana Souza
Joana Souza
MFMª Victoria Fuentes
Mª Victoria Fuentes
Eugenia BaenaEugenia Baena
Eugenia Baena
Laura CeballosLaura Ceballos
Laura Ceballos
To compare the 1-year clinical performance of lithium disilicate and resin composite CAD/CAM onlay restorations. Twenty patients that required two restorations in posterior teeth, with at least one cusp to be covered, received two onlays. One was made with IPS e.max CAD (Ivoclar-Vivadent) and the other with Lava Ultimate (3M Oral Care). Two blind observers evaluated the restorations at baseline and 1 year after the onlays were cemented, according to FDI criteria. At each recall, digital photographs, bite-wing radiographs and impressions of the restorations were taken for SEM evaluation of the interface. Results were analyzed by Mann–Whitney U and Wilcoxon tests (p < 0.05). At baseline and in the 1-year recall, both CAD/CAM materials exhibited excellent results in most criteria with similar esthetic, functional and biological properties (p > 0.05). However, deterioration in surface lustre (p = 0.020) and color match/translucency (p = 0.039) were detected for IPS e.max CAD onlays after 1-year. Under SEM evaluation, there were no statistically differences in micromorphological criteria at baseline nor after a year between IPS e.max CAD and Lava Ultimate onlays. Conclusion: After 1 year of clinical service IPS e.max CAD and Lava Ultimate onlays showed a similar clinical performance that needs to be confirmed in long-term evaluations.

20 May 2016 in Odontology
Verified
Journal Article
Closed access
PDF file
Eugenia BaenaEugenia Baena
Eugenia Baena
AFA. Flores
A. Flores
Laura CeballosLaura Ceballos
Laura Ceballos

1 September 2012 in Operative Dentistry
Verified
Journal Article
Closed access
Eugenia BaenaEugenia Baena
Eugenia Baena
M. Victoria FuentesM. Victoria Fuentes
M. Victoria Fuentes
MGMa Garrido
Ma Garrido
JRJ Rodríguez
J Rodríguez
Laura CeballosLaura Ceballos
Laura Ceballos
SUMMARY: Purpose: To compare the microhardness of several dual-cure, self-adhesive resin cements used to lute fiber posts at 24 hours and seven days after cementation. Methods: Bovine incisors were selected to lute 15 fiber posts that were 12 mm long (FRC Postec Plus size 3, Ivoclar-Vivadent). Five resin cements were tested: Multilink Automix (Ivoclar-Vivadent), without light-curing, and the self-adhesive resin cements Maxcem Elite (Kerr), RelyX Unicem (3M ESPE), G-Cem (GC), and Smartcem 2 (Dentsply), which were light-cured for 40 seconds (LED Bluephase, Ivoclar-Vivadent). Each root was embedded in chemically cured acrylic resin and stored at 37°C for 24 hours. The roots were transversally sectioned into nine specimens that were each 1 mm thick, with three specimens corresponding to each root third. Indentations (100g, 30 seconds) were performed on each section in the resin cement, at 24 hours and seven days after cementation, using a Vickers digital microdurometer (Buehler). Data were analyzed by two-way analysis of variance, Student-Newman-Keuls test, and paired t-test (p<0.05). Results: A significant influence was found (p<0.05) for the resin cement evaluated, the root third, and their interactions on microhardness values at 24 hours and seven days after post cementation. RelyX Unicem and G-Cem exhibited the highest microhardness values, whereas Multilink Automix presented the lowest. All resin cements suffered a decrease in microhardness according to root canal depth, with the exception of G-Cem and Multilink Automix at 24 hours and Smartcem 2 after seven days. After seven days, the evaluated resin cements showed a significant increase in microhardness values, with the exception of Maxcem Elite and Smartcem 2 at the coronal third. Conclusions: Microhardness of the self-adhesive resin cements when used to lute fiber posts was material-dependent and higher values were obtained in the coronal third, revealing their sensitivity to light irradiation. More information regarding the polymerization reaction of these cements is warranted. According to the current results, microhardness values were significantly higher one week after post luting.

1 January 2019 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
CGC Gonzalez-Serrano
C Gonzalez-Serrano
Eugenia BaenaEugenia Baena
Eugenia Baena
M. Victoria FuentesM. Victoria Fuentes
M. Victoria Fuentes
AAA Albaladejo
A Albaladejo
MMM Miguez-Contreras
M Miguez-Contreras
Laura CeballosLaura Ceballos
Laura Ceballos
The aim of this study was to compare the shear bond strength (SBS) of a flash-free and precoated orthodontic adhesive with a compomer orthodontic adhesive before and after thermocycling. The adhesive remnant index (ARI) was also determined for both adhesives. The adhesive remnant index (ARI) was also determined for both adhesives. Material and Methods: A total of 120 human premolars were randomly divided into two groups (n=60) according to the orthodontic adhesive used: APC Flash-Free Adhesive Coated Appliance System (APC FF) or Transbond PLUS Color Change Adhesive (TP), as control. A SBS test was performed and ARI value for each specimen was also assessed. Results were analyzed by two-way ANOVA and Tukey's Chi-square test (p0.05). APC FF and TP showed similar bond strength results. Thermocycling induced a significant decrease in SBS values for the two adhesives tested, without differences between 10,000 and 20,000 thermal cycles. Moreover, APC FF left less adhesive remnants on the enamel compared to TP. Key words:APC Flash-Free, APC cement, aging, orthodontics, resin cements.

1 October 2015
Verified
Journal Article
Closed access
Eugenia BaenaEugenia Baena
Eugenia Baena
VVValeria Vignolo
Valeria Vignolo
M. Victoria FuentesM. Victoria Fuentes
M. Victoria Fuentes
Laura CeballosLaura Ceballos
Laura Ceballos