Fabian Just

Prof. Fabian Just

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Fabian JustFabian Just
Fabian Just
ÖÖÖzhan Özen
Özhan Özen
Stefano TortoraStefano Tortora
Stefano Tortora
VKVerena Klamroth-Marganska
Verena Klamroth-Marganska
RRRobert Riener
Robert Riener
GRGeorg Rauter
Georg Rauter
Background: Arm weight compensation with rehabilitation robots for stroke patients has been successfully used to increase the active range of motion and reduce the effects of pathological muscle synergies. However, the differences in structure, performance, and control algorithms among the existing robotic platforms make it hard to effectively assess and compare human arm weight relief. In this paper, we introduce criteria for ideal arm weight compensation, and furthermore, we propose and analyze three distinct arm weight compensation methods (Average, Full, Equilibrium) in the arm rehabilitation exoskeleton ’ARMin’. The effect of the best performing method was validated in chronic stroke subjects to increase the active range of motion in three dimensional space. Methods: All three methods are based on arm models that are generalizable for use in different robotic devices and allow individualized adaptation to the subject by model parameters. The first method Average uses anthropometric tables to determine subject-specific parameters. The parameters for the second method Full are estimated based on force sensor data in predefined resting poses. The third method Equilibrium estimates parameters by optimizing an equilibrium of force/torque equations in a predefined resting pose. The parameters for all three methods were first determined and optimized for temporal and spatial estimation sensitivity. Then, the three methods were compared in a randomized single-center study with respect to the remaining electromyography (EMG) activity of 31 healthy participants who performed five arm poses covering the full range of motion with the exoskeleton robot. The best method was chosen for feasibility tests with three stroke patients. In detail, the influence of arm weight compensation on the three dimensional workspace was assessed by measuring of the horizontal workspace at three different height levels in stroke patients. Results: All three arm weight compensation methods reduced the mean EMG activity of healthy subjects to at least 49% compared with the no compensation reference. The Equilibrium method outperformed the Average and the Full methods with a highly significant reduction in mean EMG activity by 19% and 28% respectively. However, upon direct comparison, each method has its own individual advantages such as in set-up time, cost, or required technology. The horizontal workspace assessment in poststroke patients with the Equilibrium method revealed potential workspace size-dependence of arm height, while weight compensation helped maximize the workspace as much as possible. Conclusion: Different arm weight compensation methods were developed according to initially defined criteria. The methods were then analyzed with respect to their sensitivity and required technology. In general, weight compensation performance improved with the level of technology, but increased cost and calibration efforts. This study reports a systematic way to analyze the efficacy of different weight compensation methods using EMG. Additionally, the feasibility of the best method, Equilibrium, was shown by testing with three stroke patients. In this test, a height dependence of the workspace size also seemed to be present, which further highlights the importance of patient-specific weight compensation, particularly for training at different arm heights. Trial registration: ClinicalTrials.gov,NCT02720341. Registered 25 March 2016

29 November 2018 in at - Automatisierungstechnik
Verified
Journal Article
Closed access
PDF file
Fabian JustFabian Just
Fabian Just
ÖÖÖzhan Özen
Özhan Özen
PBPhilipp Bösch
Philipp Bösch
HBHanna Bobrovsky
Hanna Bobrovsky
VKVerena Klamroth-Marganska
Verena Klamroth-Marganska
GRGeorg Rauter
Georg Rauter
Undesired forces during human-robot interaction limit training effectiveness with rehabilitation robots. Thus, avoiding such undesired forces by improved mechanics, sensorics, kinematics, and controllers are the way to increase exoskeleton transparency. In this paper, the arm therapy exoskeleton ARMin IV+ was used to compare the differences in transparency offered by using the previous feed-forward model-based controller, with a disturbance observer in a study. Systematic analysis of velocity-dependent effects of controller transparency in single- and multi-joint scenarios performed in this study highlight the advantage of using disturbance observers for obtaining consistent transparency behavior at different velocities in single-joint and multi-joint movements. As the main result, the concept of the disturbance observer sets a new benchmark for ARMin transparency.

1 July 2017
Verified
Conference Paper
Closed access
Fabian JustFabian Just
Fabian Just
OOOzhan Ozen
Ozhan Ozen
Stefano TortoraStefano Tortora
Stefano Tortora
RRRobert Riener
Robert Riener
GRGeorg Rauter
Georg Rauter
Highly impaired stroke patients at early stages of recovery are unable to generate enough muscle force to lift the weight of their own arm. Accordingly, task-related training is strongly limited or even impossible. However, as soon as partial or full arm weight support is provided, patients are enabled to perform arm rehabilitation training again throughout an increased workspace. In the literature, the current solutions for providing arm weight support are mostly mechanical. These systems have components that restrict the freedom of movement or entail additional disturbances. A scalable weight compensation for upper and lower arm that is online adjustable as well as generalizable to any robotic system is necessary. In this paper, a model-based feedforward weight compensation of upper and lower arm fulfilling these requirements is introduced. The proposed method is tested with the upper extremity rehabilitation robot ARMin V, but can be applied in any other actuated exoskeleton system. Experimental results were verified using EMG measurements. These results revealed that the proposed weight compensation reduces the effort of the subjects to 26% on average and more importantly throughout the entire workspace of the robot.

1 June 2016
Verified
Conference Paper
Closed access
Fabian JustFabian Just
Fabian Just
KBKilian Baur
Kilian Baur
RRRobert Riener
Robert Riener
VKVerena Klamroth-Marganska
Verena Klamroth-Marganska
GRGeorg Rauter
Georg Rauter
Robot-assisted arm therapy is increasingly applied in neurorehabilitation. The reason for this development over the last decades was that robots relieve the therapist from hard physical work while the training intensity can be increased. Importantly, an increase in training intensity is closely linked to functional improvements of the patient. However, usability of the robot for therapists was hardly considered an important factor in rehabilitation robot development so far. We believe that usability of the robot is a key factor for acceptance of the device by therapists. In this paper, an online adaptive compensation for the ARMin rehabilitation robot is presented, which aims at improving usability of the robot. Therefore, we expect ARMin therapy to become even more effective than conventional therapy at a level that is also relevant for the patient. Additionally, improved usability relieves the therapist from unnecessary/time-consuming tasks linked to robot handling. For the ARMin, the new online adaptive compensation takes over automatic updates of changed upper and lower arm lengths as well as adaptation of shoulder angle settings to fit the patient's anthropometry. Simultaneously, the model-based compensation in ARMin is directly updated to account for hardware changes. Importantly, the online adaptive compensation provides improved performance of ARMin even at the borders of the workspace. In experiments, we could show that the adaptive online compensation relieves the force and position controller from additional burdens and increases the robot performance drastically especially at the workspace border.

27 February 2024 in IEEE Access
Verified
Journal Article
Open access
Fabian JustFabian Just
Fabian Just
CGChiara Ghinami
Chiara Ghinami
JZJan Zbinden
Jan Zbinden
MOMax Ortiz-Catalan
Max Ortiz-Catalan
Motion intent recognition for controlling prosthetic systems has long relied on machine learning algorithms. Artificial neural networks have shown great promise for solving such nonlinear classification tasks, making them a viable method for this purpose. To bring these advanced methods and algorithms beyond the confines of the laboratory and into the daily lives of prosthetic users, self-contained embedded systems are essential. However, embedded systems face constraints in size, computational power, memory footprint, and power consumption, as they must be non-intrusive and discreetly integrated into commercial prosthetic components. One promising approach to tackle these challenges is to use network quantization, which allows complying with limitations without significant loss in accuracy. Here, we compare network quantization performance for self-contained systems using TensorFlow Lite and the recently developed QKeras platform. Due to internal libraries, the use of TensorFlow Lite led to a 8 times higher flash memory usage than that of the unquantized reference network, disadvantageous for self-contained prosthetic systems. In response, we offer open-source code solutions that leverage the QKeras platform, effectively reducing flash memory requirements by 24 times compared to Tensorflow Lite. Additionally, we conducted a comprehensive comparison of state-of-the-art microcontrollers. Our results reveal that the adoption of new architectures offers substantial reductions in inference time and power consumption. These improvements pave the way for real-time decoding of motor intent using more advanced machine learning algorithms for daily life usage, possibly enabling more reliable and precise control for prosthetic users.

16 February 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
EEEric J. Earley
Eric J. Earley
JZJan Zbinden
Jan Zbinden
MMMaria Munoz-Novoa
Maria Munoz-Novoa
Fabian JustFabian Just
Fabian Just
CVChristiana Vasan
Christiana Vasan
MOMax Ortiz-Catalan
Max Ortiz-Catalan
Highly impaired individuals stand to benefit greatly from cutting-edge bionic technology, however concurrent functional deficits may complicate the adaptation of such technology. Here, we present a case in which a visually-impaired individual with bilateral burn injury amputation was provided with a novel transradial neuromusculoskeletal prosthesis comprising skeletal attachment via osseointegration and implanted electrodes in nerves and muscles for control and sensory feedback. Difficulties maintaining implant hygiene and donning and doffing the prosthesis arose due to his contralateral amputation, ipsilateral eye loss, and contralateral impaired vision necessitating continuous adaptations to the electromechanical interface. Despite these setbacks, the participant still demonstrated improvements in functional outcomes and the ability to control the prosthesis in various limb positions using the implanted electrodes. Our results demonstrate the importance of a multidisciplinary, iterative, and patient-centered approach to making cutting-edge technology accessible to patients with high levels of impairment.