Fabrizio Lo Regio

Mr. Fabrizio Lo Regio

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2023 in IEEE Sensors Journal
Verified
Journal Article
Open access
Leopoldo AngrisaniLeopoldo Angrisani
Leopoldo Angrisani
Pasquale ArpaiaPasquale Arpaia
Pasquale Arpaia
Egidio De BenedettoEgidio De Benedetto
Egidio De Benedetto
LDLuigi Duraccio
Luigi Duraccio
FRFabrizio Lo Regio
Fabrizio Lo Regio
Annarita TedescoAnnarita Tedesco
Annarita Tedesco
Brain-Computer Interfaces (BCIs) are an integration of hardware and software communication systems that allow a direct communication path between the human brain and external devices. Among the existing BCI paradigms, Steady-State Visually Evoked Potentials (SSVEPs) have gained momentum in the development of non-invasive BCI applications as they are characterized by adequate signal-to-noise ratio and information transfer rate. In recent years, the adoption of Augmented Reality (AR) head-mounted displays to render the flickering stimuli necessary for SSVEPs elicitation has become an attractive alternative to traditional computer screens. In fact, the increase in system wearability anticipates the possibility of adopting BCIs in contexts other than research laboratory. This has contributed to a steadily-increasing interest in BCIs, as also confirmed by the recent literature dedicated to the topic. In this evolving scenario, this review intends to provide a comprehensive picture of the current state-of-the-art in relation to the latest advancement of wearable BCIs based on SSVEPs classification and AR technology. The goal is to provide the reader with a systematic comparison of different technological solutions realized over the last years, thus making future research in this direction more efficient.

21 August 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
Leopoldo AngrisaniLeopoldo Angrisani
Leopoldo Angrisani
Mauro D'ArcoMauro D'Arco
Mauro D'Arco
Egidio De BenedettoEgidio De Benedetto
Egidio De Benedetto
LDLuigi Duraccio
Luigi Duraccio
FRFabrizio Lo Regio
Fabrizio Lo Regio
Annarita TedescoAnnarita Tedesco
Annarita Tedesco
This paper presents an innovative measurement method for assessing the information transfer performance of hands-free Human-Machine Interfaces (HMIs) based on eXtended Reality (XR) technology. The proposed method primarily involves the design and implementation of a dedicated XR environment, which serves as a testbed for data acquisition. Following this, an experimental campaign is conducted, involving multiple acquisition cycles for different individuals. Finally, the proposed method enables the extraction of two primary metrics, namely Selection Accuracy and Information Transfer Rate (ITR), indicative of the potential of the considered HMIs to transfer information. These metrics account for both intra-individual and inter-individual variability within the HMIs, thus providing a metrologically sound assessment of performance. The proposed method is validated through a practical case study. Three NHMIs are considered: Eye-Tracking, Head-Tracking, and Brain-Computer Interfaces (BCIs) based on Steady-State Visually Evoked Potentials (SSVEPs), as they allow hands-free interactions solely through visual observation. Without loss of generality, Microsoft HoloLens 2 and Unicorn Hybrid Black were used as XR and BCI platforms, respectively. The experimental findings obtained from eight healthy individuals allowed a comparative analysis of the performance of the three distinct HMIs, facilitating a better understanding of which interface might be more robust for a given application scenario. Overall, the proposed method represents a reliable performance assessment of innovative HMIs. This becomes increasingly significant considering the evolution of wearable HMIs and the current lack of comprehensive strategies for their characterization.

22 January 2025 in IEEE Access
Verified
Journal Article
Open access
Anna ProcopioAnna Procopio
Anna Procopio
Annarita TedescoAnnarita Tedesco
Annarita Tedesco
FRFabrizio Lo Regio
Fabrizio Lo Regio
Giuseppe CesarelliGiuseppe Cesarelli
Giuseppe Cesarelli
Leandro DonisiLeandro Donisi
Leandro Donisi
Francesco AmatoFrancesco Amato
Francesco Amato
The study of homeostatic equilibrium is a key concern in several fields, from physiology and biology to medicine and biomedical engineering. Control theory approaches can provide effective strategies to model physiological control systems, helping in understanding the dynamics of bio- and physio-logical regulation processes. However, the intrinsic complexity of living systems makes it difficult to identify unified biomodels that can represent a wide variety of physiological systems. In this context, the present work proposes a general framework to model the dynamics and describe the behavior of a wide class of multivariable physiological control systems, from the molecular to the whole-organ scale. The framework adopts a structure based on a closed-loop topology taking into account multiple inputs and outputs and with the negative feedback action intrinsically embedded within the model. The development of such a general model has at least three important repercussions: the first concerns the possibility of better understanding the basic mechanisms common to many physiological systems; the second is to develop a common theoretical framework to enable effective approaches to the analysis and design of synthetic biological control systems; finally, the investigation of the structural properties of the model in a general context, allows a guided and simplified application to specific cases. To this regard, in this paper, the existence, possible uniqueness and stability properties of the homeostatic equilibrium points of the general model are investigated; the theoretical framework is then illustrated through two real-world case-studies: (i) the PI3K/AKT/mTOR pathway nonlinear dynamics, a critical regulator of cellular growth, proliferation, and survival; (ii) the control mechanism of the neuromuscular stretch reflex, among the prime triggers implicated in postural control. Results proved the capability of the proposed framework to capture the intricate dynamics of multivariable physiological systems at different scales, highlighting the existence of asymptotically stable homeostatic equilibrium and allowing the study of the impact of transmission delays on the system’s stability. At the best of authors’ knowledge, following the paper [1] where monovariable systems where dealt with, the proposed methodology is the first attempt to represent and investigate homeostasis from the molecular up to systemic level by exploiting a unified multivariable biomodeling architecture, which makes it a novel approach to understanding homeostatic control from a broader perspective.

30 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Leopoldo AngrisaniLeopoldo Angrisani
Leopoldo Angrisani
Mauro D'ArcoMauro D'Arco
Mauro D'Arco
Egidio De BenedettoEgidio De Benedetto
Egidio De Benedetto
LDLuigi Duraccio
Luigi Duraccio
FRFabrizio Lo Regio
Fabrizio Lo Regio
Annarita TedescoAnnarita Tedesco
Annarita Tedesco
This paper proposes a method for measuring the performance of Human–Machine Interfaces based on hand-gesture recognition, implemented within eXtended Reality Head-Mounted Displays. The proposed method leverages a systematic approach, enabling performance measurement in compliance with the Guide to the Expression of Uncertainty in Measurement. As an initial step, a testbed is developed, comprising a series of icons accommodated within the field of view of the eXtended Reality Head-Mounted Display considered. Each icon must be selected through a cue-guided task using the hand gestures under evaluation. Multiple selection cycles involving different individuals are conducted to derive suitable performance metrics. These metrics are derived considering the specific parameters characterizing the hand gestures, as well as the uncertainty contributions arising from intra- and inter-individual variability in the measured quantity values. As a case study, the eXtended Reality Head-Mounted Display Microsoft HoloLens 2 and the finger-tapping gesture were investigated. Without compromising generality, the obtained results show that the proposed method can provide valuable insights into performance trends across individuals and gesture parameters. Moreover, the statistical analyses employed can determine whether increased individual familiarity with the Human–Machine Interface results in faster task completion without a corresponding decrease in accuracy. Overall, the proposed method provides a comprehensive framework for evaluating the compliance of hand-gesture-based Human–Machine Interfaces with target performance specifications related to specific application contexts.

5 December 2024 in Measurement
Verified
Journal Article
Open access
Leopoldo AngrisaniLeopoldo Angrisani
Leopoldo Angrisani
Mauro D'ArcoMauro D'Arco
Mauro D'Arco
Egidio De BenedettoEgidio De Benedetto
Egidio De Benedetto
LDLuigi Duraccio
Luigi Duraccio
FRFabrizio Lo Regio
Fabrizio Lo Regio
ATAnnarita Tedesco
Annarita Tedesco

22 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Leopoldo AngrisaniLeopoldo Angrisani
Leopoldo Angrisani
Egidio De BenedettoEgidio De Benedetto
Egidio De Benedetto
LDLuigi Duraccio
Luigi Duraccio
FRFabrizio Lo Regio
Fabrizio Lo Regio
RRRoberto Ruggiero
Roberto Ruggiero
Annarita TedescoAnnarita Tedesco
Annarita Tedesco
This work proposes an innovative method, based on the use of low-cost infrared thermography (IRT) instrumentation, to assess in real time the effectiveness of scoliosis braces. Establishing the effectiveness of scoliosis braces means deciding whether the pressure exerted by the brace on the patient’s back is adequate for the intended therapeutic purpose. Traditionally, the evaluation of brace effectiveness relies on empirical, qualitative assessments carried out by orthopedists during routine follow-up examinations. Hence, it heavily depends on the expertise of the orthopedists involved. In the state of the art, the only objective methods used to confirm orthopedists’ opinions are based on the evaluation of how scoliosis progresses over time, often exposing people to ionizing radiation. To address these limitations, the method proposed in this work aims to provide a real-time, objective assessment of the effectiveness of scoliosis braces in a non-harmful way. This is achieved by exploiting the thermoelastic effect and correlating temperature changes on the patient’s back with the mechanical pressure exerted by the braces. A system based on this method is implemented and then validated through an experimental study on 21 patients conducted at an accredited orthopedic center. The experimental results demonstrate a classification accuracy slightly below 70% in discriminating between adequate and inadequate pressure, which is an encouraging result for further advancement in view of the clinical use of such systems in orthopedic centers.