Faezeh Arab Hassani

Dr. Faezeh Arab Hassani

University of Bristol, Bristol, City of Bristol, UK
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2020 in Science
Verified
Journal Article
Closed access
PDF file
SLSunghoon Lee
Sunghoon Lee
SFSae Franklin
Sae Franklin
Faezeh Arab HassaniFaezeh Arab Hassani
Faezeh Arab Hassani
TYTomoyuki Yokota
Tomoyuki Yokota
ONOsman Goni Nayeem
Osman Goni Nayeem
TSTakao Someya
Takao Someya
A soft touch: Measuring the force it takes for a hand to grasp an object requires sensors to be placed on the fingertips, but these sensors will interfere with or affect how much force ends up being applied. Lee et al. developed a nanomesh sensor built from a series of electrospun materials (see the Perspective by Liu). Using a robotic tester, they show that this device can repeatably detect the pressure involved in gripping an object. They also show that the sensors can be attached to human fingers and that this does not affect the force used to grasp an object. Science , this issue p. 966 ; see also p. 910

9 April 2018 in ACS Nano
Verified
Journal Article
Closed access
Faezeh Arab HassaniFaezeh Arab Hassani
Faezeh Arab Hassani
RMRoshini P. Mogan
Roshini P. Mogan
GGGil G. L. Gammad
Gil G. L. Gammad
HWHao Wang
Hao Wang
SYShih-Cheng Yen
Shih-Cheng Yen
Chengkuo LeeChengkuo Lee
Chengkuo Lee

1 January 2020 in Smart Materials in Medicine
Verified
Journal Article
Open access
Faezeh Arab HassaniFaezeh Arab Hassani
Faezeh Arab Hassani
QSQiongfeng Shi
Qiongfeng Shi
FWFeng Wen
Feng Wen
THTianyiyi He
Tianyiyi He
Ahmed HarounAhmed Haroun
Ahmed Haroun
Chengkuo LeeChengkuo Lee
Chengkuo Lee

1 May 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
Faezeh Arab HassaniFaezeh Arab Hassani
Faezeh Arab Hassani
HJH. Jin
H. Jin
TYTomoyuki Yokota
Tomoyuki Yokota
TST. Someya
T. Someya
NTNitish Thakor
Nitish Thakor
Helping a dysfunctional bladder in micturition requires a system capable of both fullness detection and complete emptying.

2 December 2014 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Huicong LiuHuicong Liu
Huicong Liu
SGSudeep Gudla
Sudeep Gudla
Faezeh Arab HassaniFaezeh Arab Hassani
Faezeh Arab Hassani
CHChun Huat Heng
Chun Huat Heng
YLYong Lian
Yong Lian
Chengkuo LeeChengkuo Lee
Chengkuo Lee
This paper presents the design, modeling, and optimization of an electromagnetic energy harvesting (EMEH) device with various tube length and winding coil width. The nonlinear magnetic-spring configuration is employed for generating sufficient power from hand shaking of irregular and low-frequency vibrations. Based on the modeling and simulation, longer tube length of the EMEH device results in lower resonant frequency and stronger nonlinearity of the system and thus is more efficient for low-frequency harvesting. From the hand shaking test, it is found that a longer tube length and a shorter winding coil width could induce a higher power generation. The optimized device of tube length of 66 mm and winding coil width of 10 mm has achieved maximum power outputs of 568.66 μW at the hand shaking acceleration of 1 g and frequency of 6.7 Hz, which corresponds to the power density of 90.67 μW/cm 3 . Further improvement of the device has been achieved by increasing the coil length to 40 m. This device provides maximum power outputs of 825.36 μW at the hand shaking acceleration of 1.56 g and frequency of 6.7 Hz. This paper demonstrates a feasible design of nonlinear EMEH device with impressive output performance from hand shaking.

26 July 2017 in Advanced Science
Verified
Journal Article
Open access
PDF file
Faezeh Arab HassaniFaezeh Arab Hassani
Faezeh Arab Hassani
WPWendy Yen Xian Peh
Wendy Yen Xian Peh
GGGil Gerald Lasam Gammad
Gil Gerald Lasam Gammad
RMRoshini Priya Mogan
Roshini Priya Mogan
TNTze Kiat Ng
Tze Kiat Ng
Chengkuo LeeChengkuo Lee
Chengkuo Lee
Underactive bladder or detrusor underactivity (DU) is defined as a reduction of contraction strength or duration of the bladder wall. Despite the serious healthcare implications of DU, there are limited solutions for affected individuals. A flexible 3D printed implantable device driven by shape memory alloys (SMA) actuators is presented here for the first time to physically contract the bladder to restore voluntary control of the bladder for individuals suffering from DU. This approach is used initially in benchtop experiments with a rubber balloon acting as a model for the rat bladder to verify its potential for voiding, and that the operating temperatures are safe for the eventual implantation of the device in a rat. The device is then implanted and tested on an anesthetized rat, and a voiding volume of more than 8% is successfully achieved for the SMA‐based device without any surgical intervention or drug injection to relax the external sphincter.