Fan-Min Lin

Dr. Fan-Min Lin

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2025 in APL Bioengineering
Verified
Journal Article
Open access
YWYAO TUNG WANG
YAO TUNG WANG
Arvind MukundanArvind Mukundan
Arvind Mukundan
Riya KarmakarRiya Karmakar
Riya Karmakar
Tsung-Hsien ChenTsung-Hsien Chen
Tsung-Hsien Chen
HDHardik Dhiman
Hardik Dhiman
Hsiang-Chen WangHsiang-Chen Wang
Hsiang-Chen Wang
Graphene is a 2D material that has emerged as a versatile and advanced material for biosensing technology due to its large surface area, high conductivity, and biocompatibility. These properties make it well-suited for label-free detection of biomarkers with high sensitivity and accuracy, which is crucial for early diagnosis of various diseases, environmental monitoring, and food safety. This review highlights recent progress in graphene-based biosensor technologies, emphasizing key fabrication methods such as mechanical exfoliation, liquid phase exfoliation, chemical vapor deposition, electrochemical exfoliation, and microwave-assisted exfoliation, which are highly effective and suitable for generating graphene at an industry level. Furthermore, the study highlights characterization techniques such as Raman spectroscopy, optical spectroscopy, scanning electron microscope, transmission electron microscopy, and atomic force microscopy, which ensure quality and functionality of the graphene in biosensing applications. While hurdles like enhancing conductivity and achieving large-scale production remain, graphene-based biosensors offer a transformative approach to delivering precise and consistent results across various industries, paving the way for innovative solutions in diagnostics and monitoring systems.

8 May 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
CLChi-Hao Liu
Chi-Hao Liu
Chun-Feng ChangChun-Feng Chang
Chun-Feng Chang
ICI-Chien Chen
I-Chien Chen
FLFan-Min Lin
Fan-Min Lin
STShiow Jyu Tzou
Shiow Jyu Tzou
DPDee Pei
Dee Pei
The identification of risk factors for future prediabetes in young men remains largely unexamined. This study enrolled 6247 young ethnic Chinese men with normal fasting plasma glucose at the baseline (FPGbase), and used machine learning (Mach-L) methods to predict prediabetes after 5.8 years. The study seeks to achieve the following: 1. Evaluate whether Mach-L outperformed traditional multiple linear regression (MLR). 2. Identify the most important risk factors. The baseline data included demographic, biochemistry, and lifestyle information. Two models were built, where Model 1 included all variables and Model 2 excluded FPGbase, since it had the most profound effect on prediction. Random forest, stochastic gradient boosting, eXtreme gradient boosting, and elastic net were used, and the model performance was compared using different error metrics. All the Mach-L errors were smaller than those for MLR, thus Mach-L provided the most accurate results. In descending order of importance, the key factors for Model 1 were FPGbase, body fat (BF), creatinine (Cr), thyroid stimulating hormone (TSH), WBC, and age, while those for Model 2 were BF, white blood cell, age, TSH, TG, and LDL-C. We concluded that FPGbase was the most important factor to predict future prediabetes. However, after removing FPGbase, WBC, TSH, BF, HDL-C, and age were the key factors after 5.8 years.

29 September 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
MLMing-Chan Lee
Ming-Chan Lee
CPCheng-Tang Pan
Cheng-Tang Pan
SJShuo-Yu Juan
Shuo-Yu Juan
ZWZhi-Hong Wen
Zhi-Hong Wen
JXJin-Hao Xu
Jin-Hao Xu
FLFan-Min Lin
Fan-Min Lin
This study fabricated piezoelectric fibers of polyvinylidene fluoride (PVDF) with graphene using near-field electrospinning (NFES) technology. A uniform experimental design table U*774 was applied, considering weight percentage (1–13 wt%), the distance between needle and disk collector (2.1–3.9 mm), and applied voltage (14.5–17.5 kV). We optimized the parameters using electrical property measurements and the Kriging response surface method. Adding 13 wt% graphene significantly improved electrical conductivity, increasing from 17.7 µS/cm for pure PVDF to 187.5 µS/cm. The fiber diameter decreased from 21.4 µm in PVDF/1% graphene to 9.1 µm in PVDF/13% graphene. Adding 5 wt% graphene increased the β-phase content by 6.9%, reaching 65.4% compared to pure PVDF fibers. Material characteristics were investigated using scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction analysis (XRD), contact angle measurements, and tensile testing. Optimal parameters included 3.47 wt% graphene, yielding 15.82 mV voltage at 5 Hz and 5 N force (2.04 times pure PVDF). Force testing showed a sensitivity (S) of 7.67 log(mV/N). Fibers were attached to electrodes for piezoelectric sensor applications. The results affirmed enhanced electrical conductivity, piezoelectric performance, and mechanical strength. The optimized piezoelectric sensor could be applied to measure physiological signals, such as attaching it to the throat under different conditions to measure the output voltage. The force-to-voltage conversion facilitated subsequent analysis.

18 July 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
FLFan-Min Lin
Fan-Min Lin
JXJin-Hao Xu
Jin-Hao Xu
CSChih‐Hao Shen
Chih‐Hao Shen
SWSheng-Tang Wu
Sheng-Tang Wu
TCTa-Wei Chu
Ta-Wei Chu
Background: Insulin resistance (IR) is an underlying pathophysiology for type 2 diabetes (T2D). The Homeostasis Model Assessment of Insulin Resistance (HOMA-IR) is the simplest method for evaluating IR. At the same time, volatile organic compounds (VOCs) detected in human respiration can be correlated with specific diseases. To date, machine learning (Mach-L) has yet to be used to examine potential relationships between VOCs and IR. The present study has two aims: (1) to identify the VOCs most relevant to HOMA-IR, and (2) to use Shapley addictive explanation (SHAP) to determine the impacts of the distributions and directions of each feature in Taiwanese women. Methods: A total of 1432 Taiwanese women between the ages of 19 and 84 years were enrolled, and 344 VOCs were measured. Traditional multiple linear regression (MLR) was used as a benchmark for comparison, applying three Mach-L methods. Finally, SHAP was used to evaluate the directions of impacts of the features on HOMA-IR. Results: Six VOCs were identified as important: dimethylfuran, propanamine, aniline, butoxyethanol, and isopropyltoluene, in order from most to least important. SHAP found that dimethylfuran, isopropyltoluene, and dodecane were positively correlated to HOMA-IR, while butoxyethanol, aniline, and propanamine were negatively correlated. Conclusions: Using three different Mach-L methods, six VOCs were selected to be related to IR in Taiwanese women. According to their importance, dimethylfuran, propanamine, aniline, butoxyethanol, and isopropyltoluene could be used to help diagnose HOMA-IR. Furthermore, by using SHAP, dimethylfuran, isopropyltoluene, and dodecane had a positive and the other three had a negative influence.

2 August 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MLMing-Chan Lee
Ming-Chan Lee
CPCheng-Tang Pan
Cheng-Tang Pan
SJShuo-Yu Juan
Shuo-Yu Juan
ZWZhi-Hong Wen
Zhi-Hong Wen
JXJin-Hao Xu
Jin-Hao Xu
FLFan-Min Lin
Fan-Min Lin
This study fabricated piezoelectric fibers of polyvinylidene fluoride (PVDF) with graphene using near-field electrospinning (NFES) technology. A uniform experimental design table U*7 (7^4 ) was applied, considering weight percentage (1-13 wt%), distance between needle and disk collector (2.1-3.9 mm), and applied voltage (14.5-17.5 kV). We optimized the parameters using electrical property measurements and the Kriging response surface method. Adding 13 wt% graphene significantly improved electrical conductivity, increasing from 17.7 μS/cm for pure PVDF to 187.5 μS/cm. The fiber diameter decreased from 21.4 μm in PVDF/1% graphene to 9.1 μm in PVDF/13% graphene. Adding 5 wt% graphene increased the β-phase content by 6.9%, reaching 65.4% compared to pure PVDF fibers. Material characteristics were investigated using scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction analysis (XRD), contact angle measurements, and tensile testing. Optimal parameters included 3.47 wt% graphene, yielding 15.82 mV voltage at 5 Hz and 5 N force (2.04 times pure PVDF). Force testing showed a sensitivity (S) of 7.67493 log(mV/N). Fibers were attached to electrodes for piezoelectric sensor applications. Results affirmed enhanced electrical conductivity, piezoelectric performance, and mechanical strength. The optimized piezoelectric sensor could be applied to measure physiological signals, such as attaching it to the throat under different conditions to measure the output voltage. The force-to-voltage conversion facilitated subsequent analysis.