Cheng-Tang Pan

Prof. Cheng-Tang Pan


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CPCheng-Tang Pan
Cheng-Tang Pan
MFMark D. Francisco
Mark D. Francisco
CYC.K. Yen
C.K. Yen
SWShao-Yu Wang
Shao-Yu Wang
YSYow-Ling Shiue
Yow-Ling Shiue
One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventing possible pre-analytical error in the specimen collection and even more discomfort and pain to the patient. This paper is a review of the scientific publications on the different developed low-cost vein finder prototypes utilizing camera assisted near infrared (NIR) light technology. Methods: Electronic databases were searched online, these included PubMed (PMC), MEDLINE, Science Direct, ResearchGate, and Institute of Electrical and Electronics Engineers (IEEE) Xplore digital library. Specifically, publications with the terms vein finder prototype, NIR technology, vein detection, and infrared imaging were screened. In addition, reference lists were used to further review related publications. Results: Cannulation challenges medical practitioners because of the different factors that can be reduced by the utilization of a vein finder. A limited number of publications regarding the assessment of personnel performing cannulation were observed. Moreover, variations in methodology, number of patients, type of patients according to their demographics and materials used in the assessment of the developed prototypes were noted. Some studies were limited with regard to the actual human testing of the prototype. Conclusions: The development of a low-cost effective near infrared (NIR) vein finder remains in the phase of improvement. Since, it is being challenged by different human factors, increasing the number of parameters and participants/human for actual testing of the prototypes must also be taken into consideration for possible commercialization. Finally, it was noted that publications regarding the assessment of the performance of phlebotomists using vein finders were limited.

30 April 2020 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
AKAjay Kumar
Ajay Kumar
RCRavi Kumar Chaudhary
Ravi Kumar Chaudhary
RSRachita Singh
Rachita Singh
SSSatya P. Singh
Satya P. Singh
SWShao-Yu Wang
Shao-Yu Wang
XDXiaofeng Dai
Xiaofeng Dai
Nanotechnology utilizes engineered materials and devices which function with biological systems at the molecular level and could transform the management of neurodegenerative diseases (NDs) by provoking, reacting to, and intermingling with target sites to stimulate physiological responses while minimizing side effects. Blood–brain barrier (BBB) protects the brain from harmful agents, and transporting drugs across the BBB is a major challenge for diagnosis, targeting, and treatment of NDs. The BBB provides severe limitations for diagnosis and treatment of Alzheimer’s disease (AD), Parkinson’s disease (PD), and various other neurological diseases. Conventional drug delivery systems generally fail to cross the BBB, thus are inefficient in treatment. Although gradual development through research is ensuring the progress of nanotheranostic approaches from animal to human modeling, aspects of translational applicability and safety are a key concern. This demands a deep understanding of the interaction of body systems with nanomaterials. There are various plant-based nanobioactive compounds which are reported to have applicability in the diagnosis and treatment of these NDs. This review article provides an overview of applications of nanotheranostics in AD and PD. The review also discusses nano-enabled drug delivery systems and their current and potential applications for the treatment of various NDs.

30 March 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
MFMark D. Francisco
Mark D. Francisco
Wen-Fan ChenWen-Fan Chen
Wen-Fan Chen
CPCheng-Tang Pan
Cheng-Tang Pan
MLMing-Cheng Lin
Ming-Cheng Lin
ZWZhi-Hong Wen
Zhi-Hong Wen
YSYow-Ling Shiue
Yow-Ling Shiue
In this study, near-infrared (NIR) technology was utilized to develop a low-cost real-time near infrared (NIR) guiding device for cannulation. A portable device that can be used by medical practitioners and also by students for their skills development training in performing cannulation. Methods. First, is the development of a reflectance type optical vein finder using three (3) light emitting diode (LED) lights with 960 nm wavelength, complementary metal-oxide-semiconductor-infrared (CMOS-IR) sensor camera with 1920 × 1080 UXGA (1080P), IR filter set for the given wavelength, and an open-source image processing software. Second, is the actual in-vitro human testing in two sites: the arm and dorsal hand of 242 subjects. The following parameters were included, such as gender, age, mass index (BMI), and skin tone. In order to maximize the assessment process towards the device, the researchers included the arm circumference. This augmented subcutaneous vein imaging study using the develop vein finder device compared the difference in the captured vein images through visual and digital imaging approaches. The human testing was performed in accordance with the ethical standards of the Trinity University of Asia—Institutional Ethics Review Committee (TUA—IERC). Results. The NIR imaging system of the developed vein finder in this study showed its capability as an efficient guiding device through real-time vein pattern recognition, for both sites. Improved captured vein images were observed, having 100% visibility of vein patterns on the dorsal hand site. Fourteen (5.79%) out of 242 subjects reported non-visible peripheral subcutaneous veins in the arm sites. Conclusions. The developed vein finder device with the NIR technology and reflected light principle with low-energy consumption was efficient for real-time peripheral subcutaneous vein imaging without the application of a tourniquet. This might be utilized as a guiding device in locating the vein for the purpose of cannulation, at a very low cost as compared to the commercially available vein finders. Moreover, it may be used as an instructional device for student training in performing cannulation.

16 April 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
DLDa-Huei Lee
Da-Huei Lee
Cheng-Hsin ChuangCheng-Hsin Chuang
Cheng-Hsin Chuang
MSMuhammad Omar Shaikh
Muhammad Omar Shaikh
YDYong-Syuan Dai
Yong-Syuan Dai
SWShao-Yu Wang
Shao-Yu Wang
CPCheng-Tang Pan
Cheng-Tang Pan
Piezoresistive tactile sensors made using nanocomposite polymeric materials have been shown to possess good flexibility, electrical performance, and sensitivity. However, the sensing performance, especially in the low-pressure range, can be significantly improved by enabling uniform dispersion of the filler material and utilization of effective structural designs that improve the tactile sensing performance. In this study, a novel flexible piezoresistive tactile sensor with a grid-type microstructure was fabricated using polymer composites comprising multi-walled carbon nanotubes (MWCNTs) as the conductive filler and polydimethylsiloxane (PDMS) as the polymeric matrix. The research focused on improving the tactile sensor performance by enabling uniform dispersion of filler material and optimizing sensor design and structure. The doping weight ratio of MWCNTs in PDMS varied from 1 wt.% to 10 wt.% using the same grid structure-sensing layer (line width, line spacing, and thickness of 1 mm). The sensor with a 7 wt.% doping ratio had the most stable performance, with an observed sensitivity of 6.821 kPa−1 in the lower pressure range of 10–20 kPa and 0.029 kPa−1 in the saturation range of 30–200 kPa. Furthermore, the dimensions of the grid structure were optimized and the relationship between grid structure, sensitivity, and sensing range was correlated. The equation between pressure and resistance output was derived to validate the principle of piezoresistance. For the grid structure, dimensions with line width, line spacing, and thickness of 1, 1, and 0.5 mm were shown to have the most stable and improved response. The observed sensitivity was 0.2704 kPa−1 in the lower pressure range of 50–130 kPa and 0.0968 kPa−1 in the saturation range of 140–200 kPa. The piezoresistive response, which was mainly related to the quantum tunneling effect, can be optimized based on the dopant concentration and the grid microstructure. Furthermore, the tactile sensor showed a repeatable response, and the accuracy was not affected by temperature changes in the range of 10 to 40 °C and humidity variations from 50 to 80%. The maximum error fluctuation was about 5.6% with a response delay time of about 1.6 ms when cyclic loading tests were performed under a normal force of 1 N for 10,200 cycles. Consequently, the proposed tactile sensor shows practical feasibility for a wide range of wearable technologies and robotic applications such as touch detection and grasping.

22 January 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
RKRahul Kumar
Rahul Kumar
CPCheng-Tang Pan
Cheng-Tang Pan
YLYi-Min Lin
Yi-Min Lin
YSYow-Ling Shiue
Yow-Ling Shiue
TCTing-Sheng Chung
Ting-Sheng Chung
UJUyanahewa Gamage Shashini Janesha
Uyanahewa Gamage Shashini Janesha
Background: The global burden of respiratory diseases such as influenza, tuberculosis, and viral pneumonia necessitates rapid, accurate diagnostic tools to improve healthcare responses. Current methods, including RT-PCR and chest radiography, face limitations in accuracy, speed, accessibility, and cost-effectiveness, especially in resource-constrained settings, often delaying treatment and increasing transmission. Methods: This study introduces an Enhanced Multi-Model Deep Learning (EMDL) approach to address these challenges. EMDL integrates an ensemble of five pre-trained deep learning models (VGG-16, VGG-19, ResNet, AlexNet, and GoogleNet) with advanced image preprocessing (histogram equalization and contrast enhancement) and a novel multi-stage feature selection and optimization pipeline (PCA, SelectKBest, Binary Particle Swarm Optimization (BPSO), and Binary Grey Wolf Optimization (BGWO)). Results: Evaluated on two independent chest X-ray datasets, EMDL achieved high accuracy in the multiclass classification of influenza, pneumonia, and tuberculosis. The combined image enhancement and feature optimization strategies significantly improved diagnostic precision and model robustness. Conclusions: The EMDL framework provides a scalable and efficient solution for accurate and accessible pulmonary disease diagnosis, potentially improving treatment efficacy and patient outcomes, particularly in resource-limited settings.

23 December 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
Wen-Fan ChenWen-Fan Chen
Wen-Fan Chen
HOHsin‐You Ou
Hsin‐You Ou
KLKeng-Hao Liu
Keng-Hao Liu
ZLZhi-Yun Li
Zhi-Yun Li
CLChien-Chang Liao
Chien-Chang Liao
CPCheng-Tang Pan
Cheng-Tang Pan
Cancer is one of the common diseases. Quantitative biomarkers extracted from standard-of-care computed tomography (CT) scan can create a robust clinical decision tool for the diagnosis of hepatocellular carcinoma (HCC). According to the current clinical methods, the situation usually accounts for high expenditure of time and resources. To improve the current clinical diagnosis and therapeutic procedure, this paper proposes a deep learning-based approach, called Successive Encoder-Decoder (SED), to assist in the automatic interpretation of liver lesion/tumor segmentation through CT images. The SED framework consists of two different encoder-decoder networks connected in series. The first network aims to remove unwanted voxels and organs and to extract liver locations from CT images. The second network uses the results of the first network to further segment the lesions. For practical purpose, the predicted lesions on individual CTs were extracted and reconstructed on 3D images. The experiments conducted on 4300 CT images and LiTS dataset demonstrate that the liver segmentation and the tumor prediction achieved 0.92 and 0.75 in Dice score, respectively, by as-proposed SED method.