Farzin Golzar

Dr. Farzin Golzar

Division of Energy Systems, Department of Energy Technology, KTH-Royal Institute of Technology, Stockholm, Sweden
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
Farzin GolzarFarzin Golzar
Farzin Golzar
NHNiko Heeren
Niko Heeren
SHStefanie Hellweg
Stefanie Hellweg
RRRamin Roshandel
Ramin Roshandel

7 August 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Farzin GolzarFarzin Golzar
Farzin Golzar
DNDavid Nilsson
David Nilsson
VMViktoria E. Martín
Viktoria E. Martín
Wastewater contains considerable amounts of thermal energy. Heat recovery from wastewater in buildings could supply cities with an additional source of renewable energy. However, variations in wastewater temperature influence the performance of the wastewater treatment plant. Thus, the treatment is negatively affected by heat recovery upstream of the plant. Therefore, it is necessary to develop more accurate models of the wastewater temperature variations. In this work, a computational model based on artificial neural network (ANN) is proposed to calculate wastewater treatment plant influent temperature concerning ambient temperature, building effluent temperature and flowrate, stormwater flowrate, infiltration flowrate, the hour of day, and the day of year. Historical data related to the Stockholm wastewater system are implemented in MATLAB software to drive the model. The comparison of calculated and observed data indicated a negligible error. The main advantage of this ANN model is that it only uses historical data commonly recorded, without any requirements of field measurements for intricate heat transfer models. Moreover, Monte Carlo sensitivity analysis determined the most influential parameters during different seasons of the year. Finally, it was shown that installing heat exchangers in 40% of buildings would reduce 203 GWh year−1 heat loss in the sewage network. However, heat demand in WWTP would be increased by 0.71 GWh year−1, and the district heating company would recover 176 GWh year−1 less heat from treated water.



1 June 2018 in Journal of Energy Storage
Verified
Journal Article
Closed access
Majid AstanehMajid Astaneh
Majid Astaneh
Rodolfo Dufo-LópezRodolfo Dufo-López
Rodolfo Dufo-López
RRRamin Roshandel
Ramin Roshandel
Farzin GolzarFarzin Golzar
Farzin Golzar
JBJosé L. Bernal-Agustín
José L. Bernal-Agustín

1 July 2019 in Science of The Total Environment
Verified
Journal Article
Closed access
Farzin GolzarFarzin Golzar
Farzin Golzar
Niko HeerenNiko Heeren
Niko Heeren
SHStefanie Hellweg
Stefanie Hellweg
RRRamin Roshandel
Ramin Roshandel