Fatih Dzulfiqar

Mr. Fatih Dzulfiqar


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
ASAgus Setiawan
Agus Setiawan
FJFauzan Hanif Jufri
Fauzan Hanif Jufri
FDFatih Dzulfiqar
Fatih Dzulfiqar
MSMuhammad Gillfran Samual
Muhammad Gillfran Samual
ZAZainal Arifin
Zainal Arifin
BSBudi Sudiarto
Budi Sudiarto
Renewable energy sources have become one of the important roles for sustainable energy development. One of the promising mechanisms to deploy renewable energy is through a Virtual Power Plant (VPP), which can integrate various distributed renewable energy resources into a single controllable and deployable entity. This paper examines the opportunity for VPP adoption in Indonesia, which investigates the minimum implementation criteria, provides a gap analysis for VPP implementation, and proposes recommendations for VPP implementation in Indonesia. The implementation criteria are obtained from the literature review, including the lessons learned from other countries, and categorized into four aspects: regulatory, technical, economic, and social. The gap analysis is performed by evaluating the current state of Indonesia’s utility network in correlation with the VPP minimum implementation criteria and then provides a scoring matrix for each criterion. Lastly, the recommendations are arranged to narrow these gaps, organized into ten key focus points, and divided into four phases, initiation, preparation, piloting, and deployment, across a ten-year timeframe.

24 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HSHari Sumartono
Hari Sumartono
MHMahfudz Al Huda
Mahfudz Al Huda
BTBerkah Fajar Tk
Berkah Fajar Tk
AWAchmad Widodo
Achmad Widodo
FDFatih Dzulfiqar
Fatih Dzulfiqar
RNRatno Nuryadi
Ratno Nuryadi
Biodiesel has become an alternative fuel to substitute conventional fuel, yet challenges remain, particularly concerning water content. The presence of water in biodiesel can negatively impact engine spray and combustion properties and may lead to damage storage tanks. To address this issue, a phase shift-based capacitive sensor was developed in this study to accurately measure water concentration in biodiesel. The sensor, designed with a semi-cylindrical electrode on a glass tube, is integrated with a signal conditioning circuit and the Digilent Analog Discovery module, allowing for real-time data analysis and enhanced sensitivity in detecting low concentrations of water concentration in biodiesel. Experimental results demonstrated a direct correlation between capacitance values and phase shift, with higher capacitance leading to more significant phase shifts. A Bode plot and simulation analysis, utilizing the transfer function, validated these experimental conditions, confirming the relationship between capacitance and signal phase shift. Additionally, experiments assessing biodiesel water content revealed a proportional increase in phase shift angle with rising water concentration, measuring water concentration in biodiesel at levels as low as 800 ppm. These findings underscore that the phase shift magnitude in the sensor’s output reliably detects low-concentration water content in biodiesel. The performance of this sensor is particularly advantageous due to its high sensitivity, enabling the detection of low water concentrations that are crucial for maintaining biodiesel quality. Moreover, the real-time data analysis capability provided by the Digilent Analog Discovery highlights the sensor’s practicality and efficiency for on-the-spot monitoring, offering a significant improvement over conventional methods.

2 May 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
FDFatih Dzulfiqar
Fatih Dzulfiqar
LALia Aprilia
Lia Aprilia
AUArief Udhiarto
Arief Udhiarto
RNRatno Nuryadi
Ratno Nuryadi
Microcantilevers, as a class of Micro Electro Mechanical Systems (MEMS) sensors, exhibit remarkable sensitivity and are widely applied in environmental, physical, and biological sensing. In this work, we present the development of a highly sensitive microcontroller-based microcantilever sensor measurement system, leveraging the advantages of Direct Digital Synthesis (DDS) technology to enable real-time, precise, and repeatable measurements. The system integrates an AD9850 DDS module with an Arduino Nano V3 to generate and control a 0.5 V amplitude sine wave signal, amplified to approximately 10 V to actuate a piezoelectric element coupled to the microcantilever. The oscillatory response of the microcantilever is detected using a Wheatstone Bridge circuit, followed by signal rectification and digital conversion via the ADS1115 analog-to-digital converter. By combining hardware and software innovations, including realtime monitoring via Python, the system allows continuous tracking of the microcantilever’s resonance frequency, achieving a mass sensitivity of 7.66pg/Hz, a high signal-to-noise ratio (SNR) of 82.5 dB and demonstrating good repeatability. Integrating DDS technology with microcontroller-based control significantly advances MEMS sensor design, offering broad potential for diverse sensing applications.

16 April 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
NSNacep Suryana
Nacep Suryana
FDFatih Dzulfiqar
Fatih Dzulfiqar
HSHari Sumartono
Hari Sumartono
MHMahfudz Al Huda
Mahfudz Al Huda
VPVivi Purwandari
Vivi Purwandari
RNRatno Nuryadi
Ratno Nuryadi
Lead ion (Pb²⁺) contamination in water is a critical environmental and public health issue, posing serious risks to human health even at low concentrations. While conventional detection methods, such as atomic absorption spectroscopy (AAS) and inductively coupled plasma mass spectrometry (ICP-MS), provide high sensitivity, their reliance on sophisticated equipment limits their accessibility for broader use. This study introduces a novel phase shift-based capacitive sensor using interdigitated electrodes (IDEs) immobilized with graphene oxide (GO) for Pb²⁺ detection. The sensor leverages GO's large surface area and oxygen-containing functional groups to achieve a detection limit of 1.7 ppm and a sensitivity of 0.0556 °/ppm. Measurements revealed a strong linear correlation (R² > 0.946) between phase shift and Pb²⁺ concentration over a wide range (10–400 ppm), highlighting the sensor's linearity and reproducibility. This approach offers a simplified and cost-effective alternative to existing methods, supporting water quality monitoring and industrial safety applications.