Floris Ernst

Prof. Floris Ernst

University of Lübeck, Lübeck, Schleswig-Holstein, Germany
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FEFloris Ernst
Floris Ernst
RDR Dürichen
R Dürichen
ASA Schlaefer
A Schlaefer
ASA Schweikard
A Schweikard
In robotic radiosurgery, it is necessary to compensate for systematic latencies arising from target tracking and mechanical constraints. This compensation is usually achieved by means of an algorithm which computes the future target position. In most scientific works on respiratory motion prediction, only one or two algorithms are evaluated on a limited amount of very short motion traces. The purpose of this work is to gain more insight into the real world capabilities of respiratory motion prediction methods by evaluating many algorithms on an unprecedented amount of data. We have evaluated six algorithms, the normalized least mean squares (nLMS), recursive least squares (RLS), multi-step linear methods (MULIN), wavelet-based multiscale autoregression (wLMS), extended Kalman filtering, and ε-support vector regression (SVRpred) methods, on an extensive database of 304 respiratory motion traces. The traces were collected during treatment with the CyberKnife (Accuray, Inc., Sunnyvale, CA, USA) and feature an average length of 71 min. Evaluation was done using a graphical prediction toolkit, which is available to the general public, as is the data we used. The experiments show that the nLMS algorithm-which is one of the algorithms currently used in the CyberKnife-is outperformed by all other methods. This is especially true in the case of the wLMS, the SVRpred, and the MULIN algorithms, which perform much better. The nLMS algorithm produces a relative root mean square (RMS) error of 75% or less (i.e., a reduction in error of 25% or more when compared to not doing prediction) in only 38% of the test cases, whereas the MULIN and SVRpred methods reach this level in more than 77%, the wLMS algorithm in more than 84% of the test cases. Our work shows that the wLMS algorithm is the most accurate algorithm and does not require parameter tuning, making it an ideal candidate for clinical implementation. Additionally, we have seen that the structure of a patient's respiratory motion trace has strong influence on the outcome of prediction. Further work is needed to determine a priori the suitability of an individual's respiratory behaviour to motion prediction.

17 April 2012 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
FEFloris Ernst
Floris Ernst
LRLars Richter
Lars Richter
LMLars Matthäus
Lars Matthäus
VMVolker Martens
Volker Martens
RBRalf Bruder
Ralf Bruder
ASAchim Schweikard
Achim Schweikard

4 June 2009 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
FEFloris Ernst
Floris Ernst
ASAchim Schweikard
Achim Schweikard

23 April 2021 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
SISvenja Ipsen
Svenja Ipsen
Daniel WulffDaniel Wulff
Daniel Wulff
IKIvo Kuhlemann
Ivo Kuhlemann
ASAchim Schweikard
Achim Schweikard
FEFloris Ernst
Floris Ernst
Real-time volumetric (4D) ultrasound has shown high potential for diagnostic and therapy guidance tasks. One of the main drawbacks of ultrasound imaging to date is the reliance on manual probe positioning and the resulting user dependence. Robotic assistance could help overcome this issue and facilitate the acquisition of long-term image data to observe dynamic processes in vivo over time. The aim of this study is to assess the feasibility of robotic probe manipulation and organ motion quantification during extended imaging sessions. The system consists of a collaborative robot and a 4D ultrasound system providing real-time data access. Five healthy volunteers received liver and prostate scans during free breathing over 30 min. Initial probe placement was performed with real-time remote control with a predefined contact force of 10 N. During scan acquisition, the probe position was continuously adjusted to the body surface motion using impedance control. Ultrasound volumes, the pose of the end-effector and the estimated contact forces were recorded. For motion analysis, one anatomical landmark was manually annotated in a subset of ultrasound frames for each experiment. Probe contact was uninterrupted over the entire scan duration in all ten sessions. Organ drift and imaging artefacts were successfully compensated using remote control. The median contact force along the probe’s longitudinal axis was 10.0 N with maximum values of 13.2 and 21.3 N for liver and prostate, respectively. Forces exceeding 11 N only occurred in 0.3% of the time. Probe and landmark motion were more pronounced in the liver, with median interquartile ranges of 1.5 and 9.6 mm, compared to 0.6 and 2.7 mm in the prostate. The results show that robotic ultrasound imaging with dynamic force control can be used for stable, long-term imaging of anatomical regions affected by motion. The system facilitates the acquisition of 4D image data in vivo over extended scanning periods for the first time and holds the potential to be used for motion monitoring for therapy guidance as well as diagnostic tasks.

19 August 2011 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
FEFloris Ernst
Floris Ernst
RBRalf Bruder
Ralf Bruder
ASAlexander Schlaefer
Alexander Schlaefer
ASAchim Schweikard
Achim Schweikard

30 April 2018 in IEEE Transactions on Pattern Analysis and Machine Intelligence
Verified
Journal Article
Closed access
PJPhilipp Jauer
Philipp Jauer
IKIvo Kuhlemann
Ivo Kuhlemann
RBRalf Bruder
Ralf Bruder
ASAchim Schweikard
Achim Schweikard
FEFloris Ernst
Floris Ernst
We present a novel framework for rigid point cloud registration. Our approach is based on the principles of mechanics and thermodynamics. We solve the registration problem by assuming point clouds as rigid bodies consisting of particles. Forces can be applied between both particle systems so that they attract or repel each other. These forces are used to cause rigid-body motion of one particle system toward the other, until both are aligned. The framework supports physics-based registration processes with arbitrary driving forces, depending on the desired behaviour. Additionally, the approach handles feature-enhanced point clouds, e.g. by colours or intensity values. Our framework is freely accessible for download. In contrast to already existing algorithms, our contribution is to precisely register high-resolution point clouds with nearly constant computational effort and without the need for pre-processing, subsampling or pre-alignment. At the same time, the quality is up to 28% higher than for state-of-the-art algorithms and up to 49% higher when considering feature-enhanced point clouds. Even in the presence of noise, our registration approach is one of the most robust, on par with state-of-the-art implementations.