Svenja Ipsen

Svenja Ipsen

Auto-generated profile, based on publicly available information

Svenja Ipsen

University of Luebeck

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2021 in Current Robotics Reports
Verified
Journal Article
Open access
PDF file
Felix von HaxthausenFelix von Haxthausen
Felix von Haxthausen
SBSven Böttger
Sven Böttger
Daniel WulffDaniel Wulff
Daniel Wulff
JHJannis Hagenah
Jannis Hagenah
VGVerónica García-Vázquez
Verónica García-Vázquez
SISvenja Ipsen
Svenja Ipsen
Purpose of Review: This review provides an overview of the most recent robotic ultrasound systems that have contemporary emerged over the past five years, highlighting their status and future directions. The systems are categorized based on their level of robot autonomy (LORA). Recent Findings: Teleoperating systems show the highest level of technical maturity. Collaborative assisting and autonomous systems are still in the research phase, with a focus on ultrasound image processing and force adaptation strategies. However, missing key factors are clinical studies and appropriate safety strategies. Future research will likely focus on artificial intelligence and virtual/augmented reality to improve image understanding and ergonomics. Summary: A review on robotic ultrasound systems is presented in which first technical specifications are outlined. Hereafter, the literature of the past five years is subdivided into teleoperation, collaborative assistance, or autonomous systems based on LORA. Finally, future trends for robotic ultrasound systems are reviewed with a focus on artificial intelligence and virtual/augmented reality.

23 April 2021 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
SISvenja Ipsen
Svenja Ipsen
Daniel WulffDaniel Wulff
Daniel Wulff
IKIvo Kuhlemann
Ivo Kuhlemann
ASAchim Schweikard
Achim Schweikard
FEFloris Ernst
Floris Ernst
Real-time volumetric (4D) ultrasound has shown high potential for diagnostic and therapy guidance tasks. One of the main drawbacks of ultrasound imaging to date is the reliance on manual probe positioning and the resulting user dependence. Robotic assistance could help overcome this issue and facilitate the acquisition of long-term image data to observe dynamic processes in vivo over time. The aim of this study is to assess the feasibility of robotic probe manipulation and organ motion quantification during extended imaging sessions. The system consists of a collaborative robot and a 4D ultrasound system providing real-time data access. Five healthy volunteers received liver and prostate scans during free breathing over 30 min. Initial probe placement was performed with real-time remote control with a predefined contact force of 10 N. During scan acquisition, the probe position was continuously adjusted to the body surface motion using impedance control. Ultrasound volumes, the pose of the end-effector and the estimated contact forces were recorded. For motion analysis, one anatomical landmark was manually annotated in a subset of ultrasound frames for each experiment. Probe contact was uninterrupted over the entire scan duration in all ten sessions. Organ drift and imaging artefacts were successfully compensated using remote control. The median contact force along the probe’s longitudinal axis was 10.0 N with maximum values of 13.2 and 21.3 N for liver and prostate, respectively. Forces exceeding 11 N only occurred in 0.3% of the time. Probe and landmark motion were more pronounced in the liver, with median interquartile ranges of 1.5 and 9.6 mm, compared to 0.6 and 2.7 mm in the prostate. The results show that robotic ultrasound imaging with dynamic force control can be used for stable, long-term imaging of anatomical regions affected by motion. The system facilitates the acquisition of 4D image data in vivo over extended scanning periods for the first time and holds the potential to be used for motion monitoring for therapy guidance as well as diagnostic tasks.

28 September 2016 in Medical Physics
Verified
Journal Article
Closed access
PDF file
SISvenja Ipsen
Svenja Ipsen
RBRalf Bruder
Ralf Bruder
RORick O’brien
Rick O’brien
PKPaul J. Keall
Paul J. Keall
ASAchim Schweikard
Achim Schweikard
PPPer Rugaard Poulsen
Per Rugaard Poulsen

25 October 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
SIS Ipsen
S Ipsen
OBO Blanck
O Blanck
NLN J Lowther
N J Lowther
GLG P Liney
G P Liney
RRR Rai
R Rai
PKP J Keall
P J Keall
Radiosurgery to the pulmonary vein antrum in the left atrium (LA) has recently been proposed for non-invasive treatment of atrial fibrillation (AF). Precise real-time target localization during treatment is necessary due to complex respiratory and cardiac motion and high radiation doses. To determine the 3D position of the LA for motion compensation during radiosurgery, a tracking method based on orthogonal real-time MRI planes was developed for AF treatments with an MRI-guided radiotherapy system. Four healthy volunteers underwent cardiac MRI of the LA. Contractile motion was quantified on 3D LA models derived from 4D scans with 10 phases acquired in end-exhalation. Three localization strategies were developed and tested retrospectively on 2D real-time scans (sagittal, temporal resolution 100 ms, free breathing). The best-performing method was then used to measure 3D target positions in 2D–2D orthogonal planes (sagittal-coronal, temporal resolution 200–252 ms, free breathing) in 20 configurations of a digital phantom and in the volunteer data. The 3D target localization accuracy was quantified in the phantom and qualitatively assessed in the real data. Mean cardiac contraction was ⩽ 3.9 mm between maximum dilation and contraction but anisotropic. A template matching approach with two distinct template phases and ECG-based selection yielded the highest 2D accuracy of 1.2 mm. 3D target localization showed a mean error of 3.2 mm in the customized digital phantoms. Our algorithms were successfully applied to the 2D–2D volunteer data in which we measured a mean 3D LA motion extent of 16.5 mm (SI), 5.8 mm (AP) and 3.1 mm (LR). Real-time target localization on orthogonal MRI planes was successfully implemented for highly deformable targets treated in cardiac radiosurgery. The developed method measures target shifts caused by respiration and cardiac contraction. If the detected motion can be compensated accordingly, an MRI-guided radiotherapy system could potentially enable completely non-invasive treatment of AF.

1 January 2018 in Physica Medica
Verified
Journal Article
Closed access
NLNicholas Lowther
Nicholas Lowther
SISvenja Ipsen
Svenja Ipsen
SMSteven Marsh
Steven Marsh
OBOliver Blanck
Oliver Blanck
PKPaul Keall
Paul Keall

1 September 2019 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SISvenja Ipsen
Svenja Ipsen
RBRalf Bruder
Ralf Bruder
VGVerónica García-Vázquez
Verónica García-Vázquez
ASAchim Schweikard
Achim Schweikard
FEFloris Ernst
Floris Ernst
4D ultrasound (4D US) is gaining relevance as a tracking method in radiation therapy (RT) with modern matrix array probes offering new possibilities for real-time target detection. However, for clinical implementation of USguided RT, image quality, volumetric framerate and artifacts caused by the probe’s presence during planning and / or setup computed tomography (CT) must be quantified. We compared three diagnostic 4D US systems with matrix array probes using a commercial wire phantom to measure spatial resolution as well as a calibration and a torso phantom to assess different image quality metrics. CT artifacts were quantified in the torso phantom by calculating the total variation and percentage of affected voxels between a reference CT scan and CT scans with probes in place. We found that state-of-the-art 4D US systems with small probes can fit inside the CT bore and cause fewer metal artifacts than larger probes. US image quality varies between systems and is task-dependent. Volume sizes and framerates are much higher than the commercial guidance solution for US-guided RT, warranting further investigation regarding clinical performance for image guidance.