Filipe Neves

Dr. Filipe Neves

National Laboratory of Energy and Geology, Lisbon, Lisboa, Portugal
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2007 in Intermetallics
Verified
Journal Article
Closed access
FNFilipe Neves
Filipe Neves
IMI. Martins
I. Martins
JCJosé Brito Correia
José Brito Correia
MOM. Oliveira
M. Oliveira
Eric GAFFETEric GAFFET
Eric GAFFET

1 June 2011 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
FNFilipe Neves
Filipe Neves
FFFrancisco Manuel Braz Fernandes
Francisco Manuel Braz Fernandes
IMI. Martins
I. Martins
JCJosé Brito Correia
José Brito Correia

11 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
RTRodolfo da Silva Teixeira
Rodolfo da Silva Teixeira
RORebeca Oliveira
Rebeca Oliveira
Patrícia Freitas-RodriguesPatrícia Freitas-Rodrigues
Patrícia Freitas-Rodrigues
JMJoão M Mascarenhas
João M Mascarenhas
FNFilipe Neves
Filipe Neves
APAndersan dos Santos Paula
Andersan dos Santos Paula
The present study shows a comparison between two sintering processes, microwave and conventional sintering, for the manufacture of NiTi porous specimens starting from powder mixtures of nickel and titanium hydrogenation–dehydrogenation (HDH) milled by mechanical alloying for a short time (25 min). The samples were sintered at 850 °C for 15 min and 120 min, respectively. Both samples exhibited porosity, and the pore size results are within the range of the human bone. The NiTi intermetallic compound (B2, R-phase, and B19′) was detected in both sintered samples through X-ray diffraction (XRD) and electron backscattering diffraction (EBSD) on scanning electron microscopic (SEM). Two-step phase transformation occurred in both sintering processes with cooling and heating, the latter occurring with an overlap of the peaks, according to the differential scanning calorimetry (DSC) results. From scanning electron microscopy/electron backscatter diffraction, the R-phase and B2/B19′ were detected in microwave and conventional sintering, respectively. The instrumented ultramicrohardness results show the highest elastic work values for the conventionally sintered sample. It was observed throughout this investigation that using mechanical alloying (MA) powders enabled, in both sintering processes, good results, such as intermetallic formation and densification in the range for biomedical applications.

1 February 2016 in Materials Letters
Verified
Journal Article
Closed access
FNFilipe Neves
Filipe Neves
JCJosé Brito Correia
José Brito Correia
KHK. Hanada
K. Hanada

31 July 2008 in Intermetallics
Verified
Journal Article
Closed access
FNFilipe Neves
Filipe Neves
IMI. Martins
I. Martins
JCJosé Brito Correia
José Brito Correia
MOM. Oliveira
M. Oliveira
Eric GAFFETEric GAFFET
Eric GAFFET

3 May 2016 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
FNFilipe Neves
Filipe Neves
JCJosé Brito Correia
José Brito Correia
KHK. Hanada
K. Hanada
LSLuis Santos
Luis Santos
RGR. Gunder
R. Gunder
SSS. Schorr
S. Schorr