Francesco Cardinali

Dr. Francesco Cardinali

Electrophysiology, Istituto Cardiocentro Ticino, Lugano, Ticino, Switzerland
+1
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2025 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
MBMarco Bergonti
Marco Bergonti
DFDaniele Faccenda
Daniele Faccenda
Francesco CardinaliFrancesco Cardinali
Francesco Cardinali
TÖTardu Özkartal
Tardu Özkartal
Paolo CompagnucciPaolo Compagnucci
Paolo Compagnucci
GCGiulio Conte
Giulio Conte

5 August 2025 in Heart Rhythm O2
Verified
Journal Article
Open access
MCMichela Casella
Michela Casella
Yari ValeriYari Valeri
Yari Valeri
PCPaolo Compagnucci
Paolo Compagnucci
LFLuca Finori
Luca Finori
GVGiovanni Volpato
Giovanni Volpato
ARAntonio Dello Russo
Antonio Dello Russo
There is a lack of data on the temporal dynamics of cardiac biomarkers after radiofrequency and pulsed field ablation (PFA) catheter ablation of atrial fibrillation. To evaluate the kinetics of release of several biomarkers following pulmonary vein isolation (PVI). All patients underwent baseline and regular post-procedural blood sampling (at 3, 24, and 48 hours) to assess major markers of myocardial injury (troponin I, creatinine kinase-MB, and myoglobin) and inflammatory (C-reactive protein [CRP]). The population was stratified into 3 groups according to the ablation system: radiofrequency (RF) ablation catheter (RF group), pentaspline FarapulseTM PFA system (PFA-FAR group), and variable-loop VaripulseTM PFA system (PFA-VAR group). A total of 186 patients were included: 79 RF (42.5%), 69 PFA-FAR (37.1%), and 38 PFA-VAR (20.4%). A greater extent of myocardial injury was noticed in the PFA groups vs RF, and cellular electroporation via pentaspline PFA resulted in a greater biomarker increase compared with loop-variable PFA. Kinetics of biomarkers of inflammation increase following PVI with both PFA technologies and RF. However, both PFA systems resulted in a faster CRP biomarker recovery compared with RF, while CRP continued to increase beyond 24 hours post-ablation only in the RF group. PVI was achieved in all patients (100%) using only PFA or RF. Cellular electroporation induced by pentaspline PFA was associated with a significantly greater elevation in these cardiac biomarkers compared with variable-loop PFA and RF. After an initial increase, both PFA systems were associated with a more rapid decline in CRP levels compared with RF.

2 September 2026 in JACC: Case Reports
Verified
Journal Article
Open access
Francesco CardinaliFrancesco Cardinali
Francesco Cardinali
TRTommaso Recchioni
Tommaso Recchioni
DFDaniele Faccenda
Daniele Faccenda