Gabriel Rabanal-Rodríguez

Mr. Gabriel Rabanal-Rodríguez

Radiología, Rehabilitación y Fisioterapia, Universidad Complutense de Madrid, Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2024 in Medicina
Verified
Journal Article
Open access
PDF file
JVJuan Antonio Valera-Calero
Juan Antonio Valera-Calero
GPGustavo Plaza-Manzano
Gustavo Plaza-Manzano
Gabriel Rabanal-RodríguezGabriel Rabanal-Rodríguez
Gabriel Rabanal-Rodríguez
MAMaría José Diaz Arribas
María José Diaz Arribas
MKMateusz Kobylarz
Mateusz Kobylarz
MNMarcos Jose Navarro-Santana
Marcos Jose Navarro-Santana
Background and Objectives: Dry needling (DN) is a technique that involves inserting a thin filament needle through the skin to target myofascial trigger points for the treatment of musculoskeletal pain and dysfunction. Despite its efficacy in a broad plethora of musculoskeletal pain conditions, its safety remains a topic of debate among clinicians and researchers. The aim of this study was to provide an overview of the current practice of DN through a national survey, focusing on the frequency of its use and the incidence of adverse events (AEs), considering factors including physiotherapist experience, clinical workload, the extent of training received by practitioners, and the use of ultrasound guidance. Materials and Methods: An online cross-sectional survey was conducted. Respondents were licensed physical therapists (PTs) working in Spain. The survey covered demographics, professional data, frequency of adverse effects, and if they use ultrasound routinary for guiding interventions. Results: A total of 422 PTs participated in the study, mostly having 21–60 h of DN training (38.6%), less than 2 years of experience (36%), and not using ultrasound during the interventions (85.5%). Post-needling soreness and bent needles were the most common AEs, with most severe events rarely reported. Adverse event frequencies varied significantly based on training hours, experience, patient percentage treated with DN, and weekly clinical dedication. Clinicians with more hours of DN training or fewer years of experience reported higher incidences of certain complications. Conclusions: DN is a common intervention among PTs, with minor AEs frequently occurring and major AEs being less common but still significant. The accidental puncture of non-desired structures highlights the necessity for improve training on anatomical landmarks, needle insertion depth, cross-sectional anatomy education, and patient monitoring. To ensure safe practice, emphasize comprehensive training, adhere to safety protocols, exercise caution, and prioritize the use of ultrasound-guide is encouraged.

6 September 2025 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
Gabriel Rabanal-RodríguezGabriel Rabanal-Rodríguez
Gabriel Rabanal-Rodríguez
MNMarcos Jose Navarro-Santana
Marcos Jose Navarro-Santana
JVJuan Antonio Valera-Calero
Juan Antonio Valera-Calero
GGGuido Fabián Gómez-Chiguano
Guido Fabián Gómez-Chiguano
MKMagdalena Kocot-KęPska
Magdalena Kocot-KęPska
GPGustavo Plaza-Manzano
Gustavo Plaza-Manzano

5 February 2025 in Medicina
Verified
Journal Article
Open access
PDF file
MRMónica Lopez Redondo
Mónica Lopez Redondo
DVDavinia Vicente
Davinia Vicente
JAJavier Alvarez-González
Javier Alvarez-González
ARAlberto Roldán Ruiz
Alberto Roldán Ruiz
SSSandra Sanchez-Jorge
Sandra Sanchez-Jorge
JVJuan Antonio Valera-Calero
Juan Antonio Valera-Calero
Background and Objectives: Low back pain (LBP) is highly prevalent and often associated with altered muscle function, including in the quadratus lumborum (QL) muscle. While some studies have highlighted the clinical relevance of QL muscle stiffness in LBP, the findings remain inconsistent, and the role of this parameter in relation to clinical severity indicators is not well understood. Considering the high prevalence of myofascial trigger points among patients, objectively and reliably quantifying QL stiffness and its association with other clinical parameters could improve the identification of early stages of the condition before other alterations become apparent. Therefore, this study aimed to explore the association between QL stiffness and multiple indicators of LBP severity. Materials and Methods: A cross-sectional observational study was conducted involving the participation of seventy-six patients suffering from chronic LBP. An ultrasound scanner with shear-wave elastography (SWE) was used to determine the participants’ QL stiffness. Additional information was collected on LBP-associated pain intensity, disability, central sensitization, and quality of life. Results: QL muscle stiffness was negatively correlated with pain intensity (p < 0.01) and central sensitization (p < 0.01), and it was positively correlated with physical quality of life (p < 0.01). Muscle stiffness influenced the variance in pain intensity along with physical quality of life, central sensitization, and chronicity (together explaining 49% of the variance) but did not explain the variance in central sensitization. Conclusions: Assessing QL muscle stiffness in patients with LBP is recommended, as greater muscle softness is linked to higher pain intensity, central sensitization, and poorer physical quality of life. Regression analyses further highlighted that QL stiffness helps explain the variance in pain intensity, physical quality of life, central sensitization, and chronicity, but it did not directly affect the central sensitization variance.

23 March 2025 in Musculoskeletal Science and Practice
Verified
Journal Article
Open access
DADaniel Albert-Lucena
Daniel Albert-Lucena
MNMarcos Jose Navarro-Santana
Marcos Jose Navarro-Santana
MAMaría José Diaz Arribas
María José Diaz Arribas
Gabriel Rabanal-RodríguezGabriel Rabanal-Rodríguez
Gabriel Rabanal-Rodríguez
JVJuan Antonio Valera-Calero
Juan Antonio Valera-Calero
GPGustavo Plaza-Manzano
Gustavo Plaza-Manzano
Upper-limb neurodynamic tests are commonly used to diagnose neuropathies in this area, including cervical radiculopathy and carpal tunnel syndrome, although their diagnostic accuracy remains uncertain across different conditions and criteria. To assess the diagnostic accuracy of upper-limb neurodynamic tests and their variations and criteria for upper-limb entrapment neuropathies. A systematic review with meta-analysis was conducted in different databases (for their inception in February 2025), including studies evaluating the diagnostic accuracy of these tests. Sensitivity, specificity, likelihood ratios (LR), diagnostic odds ratios, diagnostic accuracy and the area under the curve (AUC) were calculated using a bivariate and univariate meta-analysis. The quality of evidence was evaluated using the GRADE approach, and meta-regression was performed to examine the influence of diagnostic criteria. Twelve studies were included. Likelihood ratios for neuropathic pain conditions were LR+:1.65 and LR-:0.57, for cervical radiculopathy were LR+:2 and LR-:0.47, and for carpal tunnel syndrome were LR+:1.45 and LR-:0.66. The upper-limb neurodynamic test 2A showed the highest diagnostic accuracy (AUC: 0.76), with LR+:2.59 and LR-:0.42 for cervical radiculopathy, while test 3 had the highest specificity (0.92; LR+:7, LR-:0.48). Diagnostic accuracy for carpal tunnel syndrome was lower (AUC: 0.62). Meta-regression showed significant diagnostic criteria interaction, favoring structural differentiation maneuvers (p = 0.002). Upper-limb neurodynamic tests show moderate sensitivity and low to moderate specificity for diagnosing upper-limb entrapment neuropathies, with diagnostic accuracy varying across conditions. The certainty of evidence ranges from very low to moderate, emphasizing the need for cautious clinical interpretation. Diagnostic reference criteria significantly influence test performance.

16 July 2026 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
DADaniel Albert-Lucena
Daniel Albert-Lucena
Gabriel Rabanal-RodríguezGabriel Rabanal-Rodríguez
Gabriel Rabanal-Rodríguez
MNMarcos Jose Navarro-Santana
Marcos Jose Navarro-Santana
GGGuido Fabián Gómez-Chiguano
Guido Fabián Gómez-Chiguano
ÁFÁngel Gonzalez de la Flor
Ángel Gonzalez de la Flor
GPGustavo Plaza-Manzano
Gustavo Plaza-Manzano

31 January 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Gabriel Rabanal-RodríguezGabriel Rabanal-Rodríguez
Gabriel Rabanal-Rodríguez
MNMarcos Jose Navarro-Santana
Marcos Jose Navarro-Santana
JVJuan Antonio Valera-Calero
Juan Antonio Valera-Calero
AMAna Muñoz-Rodríguez
Ana Muñoz-Rodríguez
EHElías Hernández-González
Elías Hernández-González
GPGustavo Plaza-Manzano
Gustavo Plaza-Manzano
The accurate and reliable measurement of hip flexion angles during the Straight Leg Raise (SLR) test is essential for clinical and research purposes. Despite the widespread use of motion analysis tools, few studies have examined the reliability of affordable, open-source software 0.9.5 like Kinovea for this application. This study aimed to evaluate the intra- and inter-examiner reliability of Kinovea for measuring the hip flexion angle during the SLR test in individuals with and without low back pain (LBP). An observational study was conducted involving 53 participants (38 with LBP and 15 asymptomatic controls). Each participant underwent two SLR test sessions conducted by two examiners with varying levels of experience. The hip flexion angles were measured using Kinovea software based on video recordings. Intra- and inter-examiner reliability were assessed using the Intraclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM), and Minimal Detectable Change (MDC). The effects of examiner experience and patient group were also analyzed. Kinovea demonstrated excellent intra- and inter-examiner reliability for measuring hip flexion angles, with ICC values ranging from 0.985 to 0.998. The SEM values were low (0.5°–1.5°), and the MDC values at 95% confidence ranged from 1.3° to 4.0°. No significant differences were found between the examiners’ experience or the patient groups. Thus, Kinovea offers a reliable, cost-effective, and user-friendly method for measuring hip flexion angles during the SLR test. Its consistency and precision, even across examiners with differing experience levels, highlight its potential to standardize assessments and improve diagnostic and therapeutic applications. Future research should explore its use in more complex movement analyses and diverse clinical populations to further validate its utility.