Giovanni Luca Christian Masala

Dr. Giovanni Luca Christian Masala

School of Computing, University of Kent, UK
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
KDKayisan Mary Dalmeida
Kayisan Mary Dalmeida
Giovanni Luca Christian MasalaGiovanni Luca Christian Masala
Giovanni Luca Christian Masala
Stress has been identified as one of the major causes of automobile crashes which then lead to high rates of fatalities and injuries each year. Stress can be measured via physiological measurements and in this study the focus will be based on the features that can be extracted by common wearable devices. Hence, the study will be mainly focusing on heart rate variability (HRV). This study is aimed at investigating the role of HRV-derived features as stress markers. This is achieved by developing a good predictive model that can accurately classify stress levels from ECG-derived HRV features, obtained from automobile drivers, by testing different machine learning methodologies such as K-Nearest Neighbor (KNN), Support Vector Machines (SVM), Multilayer Perceptron (MLP), Random Forest (RF) and Gradient Boosting (GB). Moreover, the models obtained with highest predictive power will be used as reference for the development of a machine learning model that would be used to classify stress from HRV features derived from heart rate measurements obtained from wearable devices. We demonstrate that HRV features constitute good markers for stress detection as the best machine learning model developed achieved a Recall of 80%. Furthermore, this study indicates that HRV metrics such as the Average of normal-to-normal (NN) intervals (AVNN), Standard deviation of the average NN intervals (SDNN) and the Root mean square differences of successive NN intervals (RMSSD) were important features for stress detection. The proposed method can be also used on all applications in which is important to monitor the stress levels in a non-invasive manner, e.g., in physical rehabilitation, anxiety relief or mental wellbeing.

1 November 2003 in Chemometrics and Intelligent Laboratory Systems
Verified
Journal Article
Closed access
SAS.R. Amendolia
S.R. Amendolia
GCG. Cossu
G. Cossu
MGM.L. Ganadu
M.L. Ganadu
BGBruno Golosio
Bruno Golosio
Giovanni Luca Christian MasalaGiovanni Luca Christian Masala
Giovanni Luca Christian Masala
GMG.M. Mura
G.M. Mura

28 July 2006 in Medical Physics
Verified
Journal Article
Closed access
PDF file
RBRoberto Bellotti
Roberto Bellotti
FCF. De Carlo
F. De Carlo
Sabina TangaroSabina Tangaro
Sabina Tangaro
GGG. Gargano
G. Gargano
GMG. Maggipinto
G. Maggipinto
Giorgio De NunzioGiorgio De Nunzio
Giorgio De Nunzio

16 October 2006 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
Donato CascioDonato Cascio
Donato Cascio
FFF. Fauci
F. Fauci
RMR. Magro
R. Magro
Giuseppe RasoGiuseppe Raso
Giuseppe Raso
RBRoberto Bellotti
Roberto Bellotti
ETE.L. Torres
E.L. Torres
The mammography is the most effective procedure for an early diagnosis of the breast cancer. In this paper, an algorithm for detecting masses in mammographic images will be presented. The database consists of 3762 digital images acquired in several hospitals belonging to the MAGIC-5 collaboration (Medical Applications on a Grid Infrastructure Connection). A reduction of the whole image's area under investigation is achieved through a segmentation process, by means of a ROI Hunter algorithm, without loss of meaningful information. In the following classification step, feature extraction plays a fundamental role: some features give geometrical information, other ones provide shape parameters. Once the features are computed for each ROI, they are used as inputs to a supervised neural network with momentum. The output neuron provides the probability that the ROI is pathological or not. Results are provided in terms of ROC and FROC curves: the area under the ROC curve was found to be AZ=0.862plusmn0.007, and we get a 2.8 FP/Image at a sensitivity of 82%. This software is included in the CAD station actually working in the hospitals belonging to the MAGIC-5 Collaboration

6 July 2009 in Medical Physics
Verified
Journal Article
Closed access
BGBruno Golosio
Bruno Golosio
Giovanni Luca Christian MasalaGiovanni Luca Christian Masala
Giovanni Luca Christian Masala
APAlessio Piccioli
Alessio Piccioli
POPiernicola Oliva
Piernicola Oliva
MCMassimo Carpinelli
Massimo Carpinelli
MTMassimo Torsello
Massimo Torsello

1 March 2014 in Computer Physics Communications
Verified
Journal Article
Closed access
BGBruno Golosio
Bruno Golosio
TSTom Schoonjans
Tom Schoonjans
ABAntonio Brunetti
Antonio Brunetti
POPiernicola Oliva
Piernicola Oliva
Giovanni Luca Christian MasalaGiovanni Luca Christian Masala
Giovanni Luca Christian Masala