Giovanni Pasini

Dr. Giovanni Pasini

IBSBC-CNR, National Research Council, Cefalù, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Giovanni PasiniGiovanni Pasini
Giovanni Pasini
Fabiano BiniFabiano Bini
Fabiano Bini
Giorgio RussoGiorgio Russo
Giorgio Russo
Albert ComelliAlbert Comelli
Albert Comelli
FMFranco Marinozzi
Franco Marinozzi
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
Radiomics aims to support clinical decisions through its workflow, which is divided into: (i) target identification and segmentation, (ii) feature extraction, (iii) feature selection, and (iv) model fitting. Many radiomics tools were developed to fulfill the steps mentioned above. However, to date, users must switch different software to complete the radiomics workflow. To address this issue, we developed a new free and user-friendly radiomics framework, namely matRadiomics, which allows the user: (i) to import and inspect biomedical images, (ii) to identify and segment the target, (iii) to extract the features, (iv) to reduce and select them, and (v) to build a predictive model using machine learning algorithms. As a result, biomedical images can be visualized and segmented and, through the integration of Pyradiomics into matRadiomics, radiomic features can be extracted. These features can be selected using a hybrid descriptive–inferential method, and, consequently, used to train three different classifiers: linear discriminant analysis, k-nearest neighbors, and support vector machines. Model validation is performed using k-fold cross-Validation and k-fold stratified cross-validation. Finally, the performance metrics of each model are shown in the graphical interface of matRadiomics. In this study, we discuss the workflow, architecture, application, future development of matRadiomics, and demonstrate its working principles in a real case study with the aim of establishing a reference standard for the whole radiomics analysis, starting from the image visualization up to the predictive model implementation.

18 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Giovanni PasiniGiovanni Pasini
Giovanni Pasini
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
Giorgio RussoGiorgio Russo
Giorgio Russo
Albert ComelliAlbert Comelli
Albert Comelli
FMFranco Marinozzi
Franco Marinozzi
Fabiano BiniFabiano Bini
Fabiano Bini
The aim of this study was to investigate the usefulness of radiomics in the absence of well-defined standard guidelines. Specifically, we extracted radiomics features from multicenter computed tomography (CT) images to differentiate between the four histopathological subtypes of non-small-cell lung carcinoma (NSCLC). In addition, the results that varied with the radiomics model were compared. We investigated the presence of the batch effects and the impact of feature harmonization on the models’ performance. Moreover, the question on how the training dataset composition influenced the selected feature subsets and, consequently, the model’s performance was also investigated. Therefore, through combining data from the two publicly available datasets, this study involves a total of 152 squamous cell carcinoma (SCC), 106 large cell carcinoma (LCC), 150 adenocarcinoma (ADC), and 58 no other specified (NOS). Through the matRadiomics tool, which is an example of Image Biomarker Standardization Initiative (IBSI) compliant software, 1781 radiomics features were extracted from each of the malignant lesions that were identified in CT images. After batch analysis and feature harmonization, which were based on the ComBat tool and were integrated in matRadiomics, the datasets (the harmonized and the non-harmonized) were given as an input to a machine learning modeling pipeline. The following steps were articulated: (i) training-set/test-set splitting (80/20); (ii) a Kruskal–Wallis analysis and LASSO linear regression for the feature selection; (iii) model training; (iv) a model validation and hyperparameter optimization; and (v) model testing. Model optimization consisted of a 5-fold cross-validated Bayesian optimization, repeated ten times (inner loop). The whole pipeline was repeated 10 times (outer loop) with six different machine learning classification algorithms. Moreover, the stability of the feature selection was evaluated. Results showed that the batch effects were present even if the voxels were resampled to an isotropic form and whether feature harmonization correctly removed them, even though the models’ performances decreased. Moreover, the results showed that a low accuracy (61.41%) was reached when differentiating between the four subtypes, even though a high average area under curve (AUC) was reached (0.831). Further, a NOS subtype was classified as almost completely correct (true positive rate ~90%). The accuracy increased (77.25%) when only the SCC and ADC subtypes were considered, as well as when a high AUC (0.821) was obtained—although harmonization decreased the accuracy to 58%. Moreover, the features that contributed the most to models’ performance were those extracted from wavelet decomposed and Laplacian of Gaussian (LoG) filtered images and they belonged to the texture feature class.. In conclusion, we showed that our multicenter data were affected by batch effects, that they could significantly alter the models’ performance, and that feature harmonization correctly removed them. Although wavelet features seemed to be the most informative features, an absolute subset could not be identified since it changed depending on the training/testing splitting. Moreover, performance was influenced by the chosen dataset and by the machine learning methods, which could reach a high accuracy in binary classification tasks, but could underperform in multiclass problems. It is, therefore, essential that the scientific community propose a more systematic radiomics approach, focusing on multicenter studies, with clear and solid guidelines to facilitate the translation of radiomics to clinical practice.

9 April 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
Fabiano BiniFabiano Bini
Fabiano Bini
EGEleonora Giovagnoli
Eleonora Giovagnoli
MDMariangela Dimarco
Mariangela Dimarco
Nicolò LaucielloNicolò Lauciello
Nicolò Lauciello
IDIldebrando D’angelo
Ildebrando D’angelo
Background: Breast cancer is the second leading cause of cancer-related mortality among women, accounting for 12% of cases. Early diagnosis, based on the identification of radiological features, such as masses and microcalcifications in mammograms, is crucial for reducing mortality rates. However, manual interpretation by radiologists is complex and subject to variability, emphasizing the need for automated diagnostic tools to enhance accuracy and efficiency. This study compares a radiomics workflow based on machine learning (ML) with a deep learning (DL) approach for classifying breast lesions as benign or malignant. Methods: matRadiomics was used to extract radiomics features from mammographic images of 1219 patients from the CBIS-DDSM public database, including 581 cases of microcalcifications and 638 of masses. Among the ML models, a linear discriminant analysis (LDA) demonstrated the best performance for both lesion types. External validation was conducted on a private dataset of 222 images to evaluate generalizability to an independent cohort. Additionally, a deep learning approach based on the EfficientNetB6 model was employed for comparison. Results: The LDA model achieved a mean validation AUC of 68.28% for microcalcifications and 61.53% for masses. In the external validation, AUC values of 66.9% and 61.5% were obtained, respectively. In contrast, the EfficientNetB6 model demonstrated superior performance, achieving an AUC of 81.52% for microcalcifications and 76.24% for masses, highlighting the potential of DL for improved diagnostic accuracy. Conclusions: This study underscores the limitations of ML-based radiomics in breast cancer diagnosis. Deep learning proves to be a more effective approach, offering enhanced accuracy and supporting clinicians in improving patient management.

11 December 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Giovanni PasiniGiovanni Pasini
Giovanni Pasini
Giorgio RussoGiorgio Russo
Giorgio Russo
CMCristina Mantarro
Cristina Mantarro
Fabiano BiniFabiano Bini
Fabiano Bini
SRSelene Richiusa
Selene Richiusa
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
Background: Radiomics shows promising results in supporting the clinical decision process, and much effort has been put into its standardization, thus leading to the Imaging Biomarker Standardization Initiative (IBSI), that established how radiomics features should be computed. However, radiomics still lacks standardization and many factors, such as segmentation methods, limit study reproducibility and robustness. Aim: We investigated the impact that three different segmentation methods (manual, thresholding and region growing) have on radiomics features extracted from 18F-PSMA-1007 Positron Emission Tomography (PET) images of 78 patients (43 Low Risk, 35 High Risk). Segmentation was repeated for each patient, thus leading to three datasets of segmentations. Then, feature extraction was performed for each dataset, and 1781 features (107 original, 930 Laplacian of Gaussian (LoG) features, 744 wavelet features) were extracted. Feature robustness and reproducibility were assessed through the intra class correlation coefficient (ICC) to measure agreement between the three segmentation methods. To assess the impact that the three methods had on machine learning models, feature selection was performed through a hybrid descriptive-inferential method, and selected features were given as input to three classifiers, K-Nearest Neighbors (KNN), Support Vector Machines (SVM), Linear Discriminant Analysis (LDA), Random Forest (RF), AdaBoost and Neural Networks (NN), whose performance in discriminating between low-risk and high-risk patients have been validated through 30 times repeated five-fold cross validation. Conclusions: Our study showed that segmentation methods influence radiomics features and that Shape features were the least reproducible (average ICC: 0.27), while GLCM features the most reproducible. Moreover, feature reproducibility changed depending on segmentation type, resulting in 51.18% of LoG features exhibiting excellent reproducibility (range average ICC: 0.68–0.87) and 47.85% of wavelet features exhibiting poor reproducibility that varied between wavelet sub-bands (range average ICC: 0.34–0.80) and resulted in the LLL band showing the highest average ICC (0.80). Finally, model performance showed that region growing led to the highest accuracy (74.49%), improved sensitivity (84.38%) and AUC (79.20%) in contrast with manual segmentation.

30 September 2024 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
PDF file
Giovanni PasiniGiovanni Pasini
Giovanni Pasini
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
CMCristina Mantarro
Cristina Mantarro
SRSelene Richiusa
Selene Richiusa
Albert ComelliAlbert Comelli
Albert Comelli
MIMassimo Ippolito
Massimo Ippolito
The aim of this study is to investigate the role of [18F]-PSMA-1007 PET in differentiating high- and low-risk prostate cancer (PCa) through a robust radiomics ensemble model. This retrospective study included 143 PCa patients who underwent [18F]-PSMA-1007 PET/CT imaging. PCa areas were manually contoured on PET images and 1781 image biomarker standardization initiative (IBSI)-compliant radiomics features were extracted. A 30 times iterated preliminary analysis pipeline, comprising of the least absolute shrinkage and selection operator (LASSO) for feature selection and fivefold cross-validation for model optimization, was adopted to identify the most robust features to dataset variations, select candidate models for ensemble modelling, and optimize hyperparameters. Thirteen subsets of selected features, 11 generated from the preliminary analysis plus two additional subsets, the first based on the combination of robust and fine-tuning features, and the second only on fine-tuning features were used to train the model ensemble. Accuracy, area under curve (AUC), sensitivity, specificity, precision, and f-score values were calculated to provide models’ performance. Friedman test, followed by post hoc tests corrected with Dunn-Sidak correction for multiple comparisons, was used to verify if statistically significant differences were found in the different ensemble models over the 30 iterations. The model ensemble trained with the combination of robust and fine-tuning features obtained the highest average accuracy (79.52%), AUC (85.75%), specificity (84.29%), precision (82.85%), and f-score (78.26%). Statistically significant differences (p < 0.05) were found for some performance metrics. These findings support the role of [18F]-PSMA-1007 PET radiomics in improving risk stratification for PCa, by reducing dependence on biopsies.

7 August 2022
Verified
Book Chapter
Closed access
PDF file
VNValentina Nepi
Valentina Nepi
Giovanni PasiniGiovanni Pasini
Giovanni Pasini
FBFabiano Bini
Fabiano Bini
FMFranco Marinozzi
Franco Marinozzi
GRGiorgio Russo
Giorgio Russo
Alessandro StefanoAlessandro Stefano
Alessandro Stefano