Franco Marinozzi

Prof. Franco Marinozzi

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Dante TrabassiDante Trabassi
Dante Trabassi
SCStefano Filippo Castiglia
Stefano Filippo Castiglia
Fabiano BiniFabiano Bini
Fabiano Bini
FMFranco Marinozzi
Franco Marinozzi
Arash AjoudaniArash Ajoudani
Arash Ajoudani
Mariano SerraoMariano Serrao
Mariano Serrao
The interpretability of gait analysis studies in people with rare diseases, such as those with primary hereditary cerebellar ataxia (pwCA), is frequently limited by the small sample sizes and unbalanced datasets. The purpose of this study was to assess the effectiveness of data balancing and generative artificial intelligence (AI) algorithms in generating synthetic data reflecting the actual gait abnormalities of pwCA. Gait data of 30 pwCA (age: 51.6 ± 12.2 years; 13 females, 17 males) and 100 healthy subjects (age: 57.1 ± 10.4; 60 females, 40 males) were collected at the lumbar level with an inertial measurement unit. Subsampling, oversampling, synthetic minority oversampling, generative adversarial networks, and conditional tabular generative adversarial networks (ctGAN) were applied to generate datasets to be input to a random forest classifier. Consistency and explainability metrics were also calculated to assess the coherence of the generated dataset with known gait abnormalities of pwCA. ctGAN significantly improved the classification performance compared with the original dataset and traditional data augmentation methods. ctGAN are effective methods for balancing tabular datasets from populations with rare diseases, owing to their ability to improve diagnostic models with consistent explainability.

22 September 2021 in Cancers
Verified
Journal Article
Open access
PDF file
Fabiano BiniFabiano Bini
Fabiano Bini
APAndrada Pica
Andrada Pica
LALaura Azzimonti
Laura Azzimonti
AGAlessandro Giusti
Alessandro Giusti
LRLorenzo Ruinelli
Lorenzo Ruinelli
PTPierpaolo Trimboli
Pierpaolo Trimboli
Artificial intelligence (AI) uses mathematical algorithms to perform tasks that require human cognitive abilities. AI-based methodologies, e.g., machine learning and deep learning, as well as the recently developed research field of radiomics have noticeable potential to transform medical diagnostics. AI-based techniques applied to medical imaging allow to detect biological abnormalities, to diagnostic neoplasms or to predict the response to treatment. Nonetheless, the diagnostic accuracy of these methods is still a matter of debate. In this article, we first illustrate the key concepts and workflow characteristics of machine learning, deep learning and radiomics. We outline considerations regarding data input requirements, differences among these methodologies and their limitations. Subsequently, a concise overview is presented regarding the application of AI methods to the evaluation of thyroid images. We developed a critical discussion concerning limits and open challenges that should be addressed before the translation of AI techniques to the broad clinical use. Clarification of the pitfalls of AI-based techniques results crucial in order to ensure the optimal application for each patient.

1 October 2017 in Clinical Biomechanics
Verified
Journal Article
Closed access
Mariano SerraoMariano Serrao
Mariano Serrao
GCGiorgia Chini
Giorgia Chini
Marco IosaMarco Iosa
Marco Iosa
CCCarlo Casali
Carlo Casali
Giovanni MoroneGiovanni Morone
Giovanni Morone
ARAlberto Ranavolo
Alberto Ranavolo

18 August 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Giovanni PasiniGiovanni Pasini
Giovanni Pasini
Fabiano BiniFabiano Bini
Fabiano Bini
Giorgio RussoGiorgio Russo
Giorgio Russo
Albert ComelliAlbert Comelli
Albert Comelli
FMFranco Marinozzi
Franco Marinozzi
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
Radiomics aims to support clinical decisions through its workflow, which is divided into: (i) target identification and segmentation, (ii) feature extraction, (iii) feature selection, and (iv) model fitting. Many radiomics tools were developed to fulfill the steps mentioned above. However, to date, users must switch different software to complete the radiomics workflow. To address this issue, we developed a new free and user-friendly radiomics framework, namely matRadiomics, which allows the user: (i) to import and inspect biomedical images, (ii) to identify and segment the target, (iii) to extract the features, (iv) to reduce and select them, and (v) to build a predictive model using machine learning algorithms. As a result, biomedical images can be visualized and segmented and, through the integration of Pyradiomics into matRadiomics, radiomic features can be extracted. These features can be selected using a hybrid descriptive–inferential method, and, consequently, used to train three different classifiers: linear discriminant analysis, k-nearest neighbors, and support vector machines. Model validation is performed using k-fold cross-Validation and k-fold stratified cross-validation. Finally, the performance metrics of each model are shown in the graphical interface of matRadiomics. In this study, we discuss the workflow, architecture, application, future development of matRadiomics, and demonstrate its working principles in a real case study with the aim of establishing a reference standard for the whole radiomics analysis, starting from the image visualization up to the predictive model implementation.

1 January 2016 in Neuroscience Letters
Verified
Journal Article
Closed access
Marco IosaMarco Iosa
Marco Iosa
Giovanni MoroneGiovanni Morone
Giovanni Morone
Fabiano BiniFabiano Bini
Fabiano Bini
Augusto FuscoAugusto Fusco
Augusto Fusco
SPStefano Paolucci
Stefano Paolucci
FMFranco Marinozzi
Franco Marinozzi

18 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Giovanni PasiniGiovanni Pasini
Giovanni Pasini
Alessandro StefanoAlessandro Stefano
Alessandro Stefano
Giorgio RussoGiorgio Russo
Giorgio Russo
Albert ComelliAlbert Comelli
Albert Comelli
FMFranco Marinozzi
Franco Marinozzi
Fabiano BiniFabiano Bini
Fabiano Bini
The aim of this study was to investigate the usefulness of radiomics in the absence of well-defined standard guidelines. Specifically, we extracted radiomics features from multicenter computed tomography (CT) images to differentiate between the four histopathological subtypes of non-small-cell lung carcinoma (NSCLC). In addition, the results that varied with the radiomics model were compared. We investigated the presence of the batch effects and the impact of feature harmonization on the models’ performance. Moreover, the question on how the training dataset composition influenced the selected feature subsets and, consequently, the model’s performance was also investigated. Therefore, through combining data from the two publicly available datasets, this study involves a total of 152 squamous cell carcinoma (SCC), 106 large cell carcinoma (LCC), 150 adenocarcinoma (ADC), and 58 no other specified (NOS). Through the matRadiomics tool, which is an example of Image Biomarker Standardization Initiative (IBSI) compliant software, 1781 radiomics features were extracted from each of the malignant lesions that were identified in CT images. After batch analysis and feature harmonization, which were based on the ComBat tool and were integrated in matRadiomics, the datasets (the harmonized and the non-harmonized) were given as an input to a machine learning modeling pipeline. The following steps were articulated: (i) training-set/test-set splitting (80/20); (ii) a Kruskal–Wallis analysis and LASSO linear regression for the feature selection; (iii) model training; (iv) a model validation and hyperparameter optimization; and (v) model testing. Model optimization consisted of a 5-fold cross-validated Bayesian optimization, repeated ten times (inner loop). The whole pipeline was repeated 10 times (outer loop) with six different machine learning classification algorithms. Moreover, the stability of the feature selection was evaluated. Results showed that the batch effects were present even if the voxels were resampled to an isotropic form and whether feature harmonization correctly removed them, even though the models’ performances decreased. Moreover, the results showed that a low accuracy (61.41%) was reached when differentiating between the four subtypes, even though a high average area under curve (AUC) was reached (0.831). Further, a NOS subtype was classified as almost completely correct (true positive rate ~90%). The accuracy increased (77.25%) when only the SCC and ADC subtypes were considered, as well as when a high AUC (0.821) was obtained—although harmonization decreased the accuracy to 58%. Moreover, the features that contributed the most to models’ performance were those extracted from wavelet decomposed and Laplacian of Gaussian (LoG) filtered images and they belonged to the texture feature class.. In conclusion, we showed that our multicenter data were affected by batch effects, that they could significantly alter the models’ performance, and that feature harmonization correctly removed them. Although wavelet features seemed to be the most informative features, an absolute subset could not be identified since it changed depending on the training/testing splitting. Moreover, performance was influenced by the chosen dataset and by the machine learning methods, which could reach a high accuracy in binary classification tasks, but could underperform in multiclass problems. It is, therefore, essential that the scientific community propose a more systematic radiomics approach, focusing on multicenter studies, with clear and solid guidelines to facilitate the translation of radiomics to clinical practice.