Purpose: To evaluate the benefit of the additional available information present in spectral CT datasets, as compared to conventional CT datasets, when utilizing convolutional neural networks for fully automatic localisation and classification of liver lesions in CT images. Materials and Methods: Conventional and spectral CT images (iodine maps, virtual monochromatic images (VMI)) were obtained from a spectral dual-layer CT system. Patient diagnosis were known from the clinical reports and classified into healthy, cyst and hypodense metastasis. In order to compare the value of spectral versus conventional datasets when being passed as input to machine learning algorithms, we implemented a weakly-supervised convolutional neural network (CNN) that learns liver lesion localisation without pixel-level ground truth annotations. Regions-of-interest are selected automatically based on the localisation results and are used to train a second CNN for liver lesion classification (healthy, cyst, hypodense metastasis). The accuracy of lesion localisation was evaluated using the Euclidian distances between the ground truth centres of mass and the predicted centres of mass. Lesion classification was evaluated by precision, recall, accuracy and F1-Score. Results: Lesion localisation showed the best results for spectral information with distances of 8.22 ± 10.72 mm, 8.78 ± 15.21 mm and 8.29 ± 12.97 mm for iodine maps, 40 keV and 70 keV VMIs, respectively. With conventional data distances of 10.58 ± 17.65 mm were measured. For lesion classification, the 40 keV VMIs achieved the highest overall accuracy of 0.899 compared to 0.854 for conventional data. Conclusion: An enhanced localisation and classification is reported for spectral CT data, which demonstrates that combining machine-learning technology with spectral CT information may in the future improve the clinical workflow as well as the diagnostic accuracy.
Background: A novel, multi-energy, dual-layer spectral detector computed tomography (SDCT) is commercially available now with the vendor’s claim that it yields the same or better quality of polychromatic, conventional CT images like modern single-energy CT scanners without any radiation dose penalty. Purpose: To intra-individually compare the quality of conventional polychromatic CT images acquired with a dual-layer spectral detector (SDCT) and the latest generation 128-row single-energy-detector (CT128) from the same manufacturer. Material and Methods: Fifty patients underwent portal-venous phase, thoracic-abdominal CT scans with the SDCT and prior CT128 imaging. The SDCT scanning protocol was adapted to yield a similar estimated dose length product (DLP) as the CT128. Patient dose optimization by automatic tube current modulation and CT image reconstruction with a state-of-the-art iterative algorithm were identical on both scanners. CT image contrast-to-noise ratio (CNR) was compared between the SDCT and CT128 in different anatomic structures. Image quality and noise were assessed independently by two readers with 5-point-Likert-scales. Volume CT dose index (CTDIvol), and DLP were recorded and normalized to 68 cm acquisition length (DLP68). Results: The SDCT yielded higher mean CNR values of 30.0% ± 2.0% (26.4–32.5%) in all anatomic structures ( P < 0.001) and excellent scores for qualitative parameters surpassing the CT128 (all P < 0.0001) with substantial inter-rater agreement (κ ≥ 0.801). Despite adapted scan protocols the SDCT yielded lower values for CTDIvol (–10.1 ± 12.8%), DLP (−13.1 ± 13.9%), and DLP68 (–15.3 ± 16.9%) than the CT128 (all P < 0.0001). Conclusion: The SDCT scanner yielded better CT image quality compared to the CT128 and lower radiation dose parameters.
1 February 2022 in Quantitative Imaging in Medicine and Surgery
Detection of patients with chronic thromboembolic pulmonary hypertension by volumetric iodine quantification in the lung—a case control study Jan Robert Kroeger, Jakob Zöllner, Felix Gerhardt, Stephan Rosenkranz, Roman Johannes Gertz, Shir Kerszenblat, Gregor Pahn, David Maintz, Alexander C. Bunck
Virtual non-calcium (VNCa) images from dual-energy computed tomography (DECT) have shown high potential to diagnose bone marrow disease of the spine, which is frequently disguised by dense trabecular bone on conventional CT. In this study, we aimed to define reference values for VNCa bone marrow images of the spine in a large-scale cohort of healthy individuals. DECT was performed after resection of a malignant skin tumor without evidence of metastatic disease. Image analysis was fully automated and did not require specific user interaction. The thoracolumbar spine was segmented by a pretrained convolutional neuronal network. Volumetric VNCa data of the spine’s bone marrow space were processed using the maximum, medium, and low calcium suppression indices. Histograms of VNCa attenuation were created for each exam and suppression setting. We included 500 exams of 168 individuals (88 female, patient age 61.0 ± 15.9). A total of 8298 vertebrae were segmented. The attenuation histograms’ overlap of two consecutive exams, as a measure for intraindividual consistency, yielded a median of 0.93 (IQR: 0.88–0.96). As our main result, we provide the age- and sex-specific bone marrow attenuation profiles of a large-scale cohort of individuals with healthy trabecular bone structure as a reference for future studies. We conclude that artificial-intelligence-supported, fully automated volumetric assessment is an intraindividually robust method to image the spine’s bone marrow using VNCa data from DECT.
Objectives: Few studies have reported in vivo measurements of electron density (ED) and effective atomic number (Zeff) in normal brain tissue. To address this gap, dual-energy computed tomography (DECT)-derived ED and Zeff maps were used to characterize normal-appearing adult brain tissues, evaluate age-related changes, and investigate correlations with myelin partial volume (Vmy) from synthetic magnetic resonance imaging (MRI). Materials and Methods: Thirty patients were retrospectively analyzed. The conventional computed tomography (CT) value (CTconv), ED, Zeff, and Vmy were measured in the normal-appearing gray matter (GM) and white matter (WM) regions of interest. Vmy and DECT-derived parameters were compared between WM and GM. Correlations between Vmy and DECT parameters and between age and DECT parameters were analyzed. Results: Vmy was significantly greater in WM than in GM, whereas CTconv, ED, and Zeff were significantly lower in WM than in GM (all p < 0.001). Zeff exhibited a stronger negative correlation with Vmy (ρ = −0.756) than CTconv (ρ = −0.705) or ED (ρ = −0.491). ED exhibited weak to moderate negative correlations with age in nine of the 14 regions. In contrast, Zeff exhibited weak to moderate positive correlations with age in nine of the 14 regions. CTconv exhibited negligible to insignificant correlations with age: Conclusions: This study revealed distinct GM–WM differences in ED and Zeff along with opposing age-related changes in these quantities. Therefore, myelin may have substantially contributed to the lower Zeff observed in WM, which underlies the GM–WM contrast observed on non-contrast-enhanced CT.