Xiaoning GUAN

Dr. Xiaoning GUAN

Donghua University, Shanghai, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
Xiaoning GUANXiaoning GUAN
Xiaoning GUAN
Jing LinJing Lin
Jing Lin
JHJiaxiang Han
Jiaxiang Han
XGXiaodong GAO
Xiaodong GAO
YZYing Zhang
Ying Zhang
LWLu Wang
Lu Wang
This study explored the ideal period for wearing masks to prevent the physiological and psychological problems associated with long-term face mask use during respiratory infections by healthcare workers. Breathing simulators, surgical masks (SM) and medical respirators (PM) were prepared for two to eight hours. Changes in the comfort of masks (facial skin temperature, breathing resistance, and moisture permeability) and protection (filtration efficiency, resistance to blood penetration, and colony count) were assessed. The results demonstrated that the masks offered efficient liquid-particle filtering even after eight hours of use. However, the number of bacterial colonies using PM and SM grew significantly after two and four hours, respectively. Concerning comfort, the inspiratory resistance of masks rose dramatically after two hours, whereas the moisture permeability declined considerably after four hours. In addition, skin temperature had a significant increase within two hours, which may result in facial discomfort. When conditions permitted, the hospital staff was instructed to replace their masks every two hours.

9 July 2023 in Materials
Verified
Journal Article
Open access
PDF file
Jing LinJing Lin
Jing Lin
Xiaoning GUANXiaoning GUAN
Xiaoning GUAN
MNMark Nutley
Mark Nutley
JPJean M. Panneton
Jean M. Panneton
ZZZe Zhang
Ze Zhang
LWLu Wang
Lu Wang
In situ fenestration of endovascular stent-grafts has become a mainstream bailout technique to treat complex emergent aneurysms while maintaining native anatomical visceral and aortic arch blood supplies. Fabric tearing from creating the in situ fenestration using balloon angioplasty may extend beyond the intended diameter over time. Further tearing may result from the physiologic pulsatile motion at the branching site. A resultant endoleak at the fenestrated sites in stent-grafts could ultimately lead to re-pressurization of the aortic sac and, eventually, rupture. In an attempt to address this challenge, plain woven fabrics were designed. They hold a specific corona surrounding a square-shaped cluster with a plain weave fabric structure, a 2/2 twill, or a honeycomb. The corona was designed to stop potential further tearing of the fabric caused by the initial balloon angioplasty and stent or later post-implantation motion. The cluster within the corona was designed with relatively loose fabric structures (plain weave, 2/2 twill weave, and honeycomb) to facilitate the laser fenestration. Two commercial devices, Anaconda (Vascutek, Terumo Aortic) and Zenith TX2 (Cook), were selected as controls for comparison against this new design. All the specimens were characterized by morphology, thickness, and water permeability. The results demonstrated that all specimens with a low thickness and water permeability satisfied the requirements for a stent graft material that would be low profile and resistant to endoleaks. The in situ fenestrations were performed on all fabrics utilizing an Excimer laser followed by balloon angioplasty. The fabrics were further observed by light microscopy and scanning electron microscopy. The dimension of the fenestrated apertures was smaller than the balloon’s diameter. The tearing was effectively confined within the corona. The clinical acceptability of this concept deserves additional bench testing and animal experimentation.