Hyeong-U Kim

Prof. Dr. Hyeong-U Kim

Korea Institute of Machinery and Materials, Daejeon, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2015 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
CAChisung Ahn
Chisung Ahn
JLJinhwan Lee
Jinhwan Lee
Hyeong-U KimHyeong-U Kim
Hyeong-U Kim
HBHunyoung Bark
Hunyoung Bark
MJMinhwan Jeon
Minhwan Jeon
Taesung KimTaesung Kim
Taesung Kim

9 January 2020 in Small
Verified
Journal Article
Closed access
PDF file
Hyeong-U KimHyeong-U Kim
Hyeong-U Kim
VKVinit Kanade
Vinit Kanade
MKMansu Kim
Mansu Kim
KKKi Seok Kim
Ki Seok Kim
BAByeong‐Seon An
Byeong‐Seon An
Taesung KimTaesung Kim
Taesung Kim

12 August 2015 in Nanotechnology
Verified
Journal Article
Closed access
MJMin Hwan Jeon
Min Hwan Jeon
CAChisung Ahn
Chisung Ahn
Hyeong-U KimHyeong-U Kim
Hyeong-U Kim
KKKyong Nam Kim
Kyong Nam Kim
TLTai Zhe LiN
Tai Zhe LiN
GYGeun Young Yeom
Geun Young Yeom
A few-layered molybdenum disulfide (MoS 2 ) thin film grown by plasma enhanced chemical vapor deposition was etched using a CF 4 inductively coupled plasma, and the possibility of controlling the MoS 2 layer thickness to a monolayer of MoS 2 over a large area substrate was investigated. In addition, damage and contamination of the remaining MoS 2 layer surface after etching and a possible method for film recovery was also investigated. The results from Raman spectroscopy and atomic force microscopy showed that one monolayer of MoS 2 was etched by exposure to a CF 4 plasma for 20 s after an initial incubation time of 20 s, i.e., the number of MoS 2 layers could be controlled by exposure to the CF 4 plasma for a certain processing time. However, XPS data showed that exposure to CF 4 plasma induced a certain amount of damage and contamination by fluorine of the remaining MoS 2 surface. After exposure to a H 2 S plasma for more than 10 min, the damage and fluorine contamination of the etched MoS 2 surface could be effectively removed.

1 March 2019 in Applied Surface Science
Verified
Journal Article
Closed access
Hyeong-U KimHyeong-U Kim
Hyeong-U Kim
MKMansu Kim
Mansu Kim
YJYinhua Jin
Yinhua Jin
YHYuhwan Hyeon
Yuhwan Hyeon
KKKi Seok Kim
Ki Seok Kim
TKTaesung Kim
Taesung Kim

18 May 2020 in Advanced Energy Materials
Verified
Journal Article
Closed access
PDF file
KPKyu‐Young Park
Kyu‐Young Park
JLJin‐Myoung Lim
Jin‐Myoung Lim
NLNorman S. Luu
Norman S. Luu
JDJulia R. Downing
Julia R. Downing
SWShay G. Wallace
Shay G. Wallace
MHMark C. Hersam
Mark C. Hersam

3 October 2016 in Scientific Reports
Verified
Journal Article
Open access
Hyeong-U KimHyeong-U Kim
Hyeong-U Kim
HKHye Youn Kim
Hye Youn Kim
AKAtul Kulkarni
Atul Kulkarni
CAChisung Ahn
Chisung Ahn
YJYinhua Jin
Yinhua Jin
Taesung KimTaesung Kim
Taesung Kim
This paper reports a biosensor based on a MoS2-graphene (MG) composite that can measure the parathyroid hormone (PTH) concentration in serum samples from patients. The interaction between PTH and MG was analysed via an electrochemical sensing technique. The MG was functionalized using l-cysteine. Following this, PTH could be covalently immobilized on the MG sensing electrode. The properties of MG were evaluated using scanning electron microscopy, high-resolution transmission electron microscopy, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectrometry. Following optimization of immobilized materials—such as MG, PTH, and alkaline phosphatase (ALP)—the performance of the MG sensor was investigated via cyclic voltammetry, to assess its linearity, repeatability, and reproducibility. Electrochemical impedance spectroscopy was performed on graphene oxide (GO) and MG-modified electrodes to confirm the capture of a monoclonal antibody (MAb) targeting PTH. Furthermore, the ALP-PTH-MG sensor exhibits a linear response towards PTH from artificial serum over a range of 1–50 pg mL−1. Moreover, patient sera (n = 30) were evaluated using the ALP-PTH-MG sensor and compared using standard equipment (Roche E 170). The P-value is less than 0.01 when evaluated with a t-test using Welch’s correction. This implies that the fabricated sensor can be deployed for medical diagnosis.