Guilherme Gloriano de Souza

Mr. Guilherme Gloriano de Souza

Federal University of Mato Grosso do Sul, Campo Grande, Mato Grosso do Sul, Brazil
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Guilherme Gloriano de SouzaGuilherme Gloriano de Souza
Guilherme Gloriano de Souza
RSRicardo Ribeiro Dos Santos
Ricardo Ribeiro Dos Santos
RGRuben Barros Godoy
Ruben Barros Godoy
The expansion of electric vehicles (EVs) challenges electricity grids by increasing charging demand, thereby making Demand-Side Management (DSM) strategies essential to maintaining balance between supply and demand. Among these strategies, the Valley-Filling approach has emerged as a promising method to optimize renewable energy utilization and alleviate grid stress. This study introduces a novel heuristic, Load Conservation Valley-Filling (LCVF), which builds on the Classical and Optimistic Valley-Filling approaches by incorporating dynamic load conservation principles, enabling better alignment of EV charging with grid capacity. We conducted a comprehensive analysis of the heuristic across five EV charging scenarios. In both the Original and Flexible scenarios, LCVF reduced energy demand by up to 10.65%, demonstrating its adaptability and effectiveness. Notably, in the 24-hour Availability scenario, LCVF achieved a reduction of over 20% in energy demand compared to CVF. These findings indicate that LCVF could play a crucial role in enhancing real-world EV charging infrastructure, boosting energy efficiency and grid stability. By integrating DSM strategies like LCVF, energy grids can better accommodate renewable energy sources, promoting more sustainable operations.

18 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
Guilherme Gloriano de SouzaGuilherme Gloriano de Souza
Guilherme Gloriano de Souza
RSRicardo Santos
Ricardo Santos
ESERLANDSON F. SARAIVA FERREIRA SARAIVA
ERLANDSON F. SARAIVA FERREIRA SARAIVA
Photovoltaic (PV) systems are dependent on solar irradiation and environmental temperature to achieve their best performance. One of the challenges in the photovoltaic industry is performing maintenance as soon as a system is not working at its full generation capacity. The lack of a proper maintenance schedule affects power generation performance and can also decrease the lifetime of photovoltaic modules. Regarding the impact of environmental variables on the performance of PV systems, research has shown that soiling is the third most common reason for power loss in photovoltaic power plants, after solar irradiance and environmental temperature. This paper proposes a new statistical predictor for forecasting PV power generation by measuring environmental variables and the estimated mass particles (soiling) on the PV system. Our proposal was based on the fit of a nonlinear mixed-effects model, according to a log-logistic function. Two advantages of this approach are that it assumes a nonlinear relationship between the generated power and the environmental conditions (solar irradiance and the presence of suspended particulates) and that random errors may be correlated since the power generation measurements are recorded longitudinally. We evaluated the model using a dataset comprising environmental variables and power samples that were collected from October 2019 to April 2020 in a PV power plant in mid-west Brazil. The fitted model presented a maximum mean squared error (MSE) of 0.0032 and a linear coefficient correlation between the predicted and observed values of 0.9997. The estimated average daily loss due to soiling was 1.4%.

Verified
Journal Article
Open access
PDF file
Guilherme Gloriano de SouzaGuilherme Gloriano de Souza
Guilherme Gloriano de Souza
ENEmerson G. R. Nobre
Emerson G. R. Nobre
RSRicardo Santos
Ricardo Santos
RGRuben Godoy
Ruben Godoy
Electric vehicle (EV) fleets are expanding rapidly and will place substantial demand on distribution grids. Day-ahead scheduling of city-scale EV charging constitutes a constrained multi-objective optimization problem that must balance peak load, load variation, and valley utilization simultaneously. This paper proposes a structured warm-start strategy that embeds a load-conservation valley-filling (LCVF) heuristic into the NSGA-III metaheuristic, seeding the entire initial population with grid-compliant, valley-filling schedules before the first generation runs. This search-space shaping approach restricts the evolutionary search to a feasible subspace defined by LCVF, enabling convergence that random initialization cannot achieve within the same computational budget. On four seasonal city-level instances derived from real electricity consumption data from Campo Grande, MS, Brazil (N=50,336 vehicles), VF–NSGA-III reduces peak load by 0.54–2.52% (mean 1.31%) relative to standalone LCVF while requiring only ≈1.5% of its runtime. The warm-start provides a structural advantage that population scaling alone cannot overcome: LCVF-initialized NSGA-III with Npop=10 achieves a hypervolume 35% above the randomly initialized variant with Npop=100. A 32-day generalization study (June 2022–May 2023) confirms a mean peak-load reduction of 4.91% over standalone LCVF and 4.93% over randomly initialized NSGA-III across all seasons, demonstrating consistent performance over a full annual demand cycle.

18 July 2021
Verified
Conference Paper
Open access
PDF file
Guilherme Gloriano de SouzaGuilherme Gloriano de Souza
Guilherme Gloriano de Souza
RSRicardo Santos
Ricardo Santos
ESERLANDSON F. SARAIVA FERREIRA SARAIVA
ERLANDSON F. SARAIVA FERREIRA SARAIVA
A sujidade nos módulos fotovoltaicos tem um impacto direto na geração de energia solar. Uma forma de minimizar esse impacto é identificar as perdas na geração de energia devido à sujidade e acionar procedimentos de limpeza. Este trabalho apresenta um sistema de hardware/software composto por uma plataforma eletrônica para aquisição de variáveis ambientais e um modelo não-linear de efeitos mistos (NLME) para estimar a geração de energia das usinas solares. Esse sistema possibilita que usuários possam analisar as perdas de geração em função da sujidade em usinas solares fotovoltaicas. O modelo foi avaliado usando um conjunto de dados real composto de medições de energia gerada e variáveis ambientais de Outubro/2019 a Abril/2020. O modelo ajustado apresentou um erro quadrático médio de 0,0044 e os resultados mostraram perdas diárias de energia abaixo de 1,1%. Soiling on the photovoltaic modules has a straight impact on the solar energy generation. One way to minimize such impact is to identify the power generation losses due to soiling and perform cleanup procedures. Towards this end, this work presents a hardware/software system comprised of an electronic platform for the acquisition of environmental variables and a non-linear mixed effect model (NLME) to estimate the power generation from the solar power plants. The system allows users to analyze the soiling impact on energy generation on photovoltaic solar plants. The model was evaluated using a real dataset comprised of measurements of generated power and environmental variables from October 2019 up to April 2020. The fitted model has presented a mean square error of 0.0044 and the results showed daily power losses below 1.1%.