Guillem Cornella-Barba

Mr. Guillem Cornella-Barba

Department of Mechanical and Aerospace Engineering, University of California, Irvine, Irvine, California, USA
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Guillem Cornella-BarbaGuillem Cornella-Barba
Guillem Cornella-Barba
SOShusuke Okita
Shusuke Okita
Zheng LiZheng Li
Zheng Li
DRDavid Reinkensmeyer
David Reinkensmeyer
Wearable activity sensors typically count movement quantity, such as the number of steps taken or the number of upper extremity (UE) counts achieved. However, for some applications, such as neurologic rehabilitation, it may be of interest to quantify the quality of the movement experience (QOME), defined, for example, as how diverse or how complex movement epochs are. We previously found that individuals with UE impairment after stroke exhibited differences in their distributions of forearm postures across the day and that these differences could be quantified with kurtosis—an established statistical measure of the peakedness of distributions. In this paper, we describe further progress toward the goal of providing real-time feedback to try to help people learn to modulate their movement diversity. We first asked the following: to what extent do different movement activities induce different values of kurtosis? We recruited seven unimpaired individuals and evaluated a set of 12 therapeutic activities for their forearm postural diversity using kurtosis. We found that the different activities produced a wide range of kurtosis values, with conventional rehabilitation therapy exercises creating the most spread-out distribution and cup stacking the most peaked. Thus, asking people to attempt different activities can vary movement diversity, as measured with kurtosis. Next, since kurtosis is a computationally expensive calculation, we derived a novel recursive algorithm that enables the real-time calculation of kurtosis. We show that the algorithm reduces computation time by a factor of 200 compared to an optimized kurtosis calculation available in SciPy, across window sizes. Finally, we embedded the kurtosis algorithm on a commercial smartwatch and validated its accuracy using a robotic simulator that “wore” the smartwatch, emulating movement activities with known kurtosis. This work verifies that different movement tasks produce different values of kurtosis and provides a validated algorithm for the real-time calculation of kurtosis on a smartwatch. These are needed steps toward testing QOME-focused, wearable rehabilitation.

21 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Guillem Cornella-BarbaGuillem Cornella-Barba
Guillem Cornella-Barba
AFAndria Farrens
Andria Farrens
CJChristopher A. Johnson
Christopher A. Johnson
Luis Garcia-FernandezLuis Garcia-Fernandez
Luis Garcia-Fernandez
VCVicky Chan
Vicky Chan
DRDavid Reinkensmeyer
David Reinkensmeyer
Many medical conditions impair proprioception but there are few easy-to-deploy technologies for assessing proprioceptive deficits. Here, we developed a method—called “OpenPoint”—to quantify upper extremity (UE) proprioception using only a webcam as the sensor. OpenPoint automates a classic neurological test: the ability of a person to use one hand to point to a finger on their other hand with vision obscured. Proprioception ability is quantified with pointing error in the frontal plane measured by a deep-learning-based, computer vision library (MediaPipe). In a first experiment with 40 unimpaired adults, pointing error significantly increased when we replaced the target hand with a fake hand, verifying that this task depends on the availability of proprioceptive information from the target hand, and that we can reliably detect this dependence with computer vision. In a second experiment, we quantified UE proprioceptive ability in 16 post-stroke participants. Individuals post stroke exhibited increased pointing error (p < 0.001) that was correlated with finger proprioceptive error measured with an independent, robotic assessment (r = 0.62, p = 0.02). These results validate a novel method to assess UE proprioception ability using affordable computer technology, which provides a potential means to democratize quantitative proprioception testing in clinical and telemedicine environments.

27 June 2025 in Proceedings of the ACM on Human-Computer Interaction
Verified
Journal Article
Open access
Guillem Cornella-BarbaGuillem Cornella-Barba
Guillem Cornella-Barba
BDBruno Dumas
Bruno Dumas
MOMehdi Ousmer
Mehdi Ousmer
Santiago Villarreal NarvaezSantiago Villarreal Narvaez
Santiago Villarreal Narvaez
Jean VanderdoncktJean Vanderdonckt
Jean Vanderdonckt
ACAdrien Chaffangeon Caillet
Adrien Chaffangeon Caillet
We introduce TapStrapGest , a novel solution for customizable ring-based multi-finger gestures, encompassing the process from gesture elicitation to gesture recognition. Recognizing the growing demand for intuitive and customizable gesture interaction with fingers, TapStrapGest uses Tap Strap to enable users to perform simple and complex multi-finger gestures using smart rings. We conducted a gesture elicitation study, detailing the systematic process of soliciting and refining a custom set of user-defined ring-based finger gestures through participatory design and ergonomic considerations, including thinking time, goodness of fit, and memorization. Subsequently, we delve into the technical underpinnings of gesture recognition. We reduce the dimensionality of a dataset of 27 gesture classes from 21 to 15 by filtering, then from 15 to 5 by a Principal Component Analysis. We implement and compare four machine learning algorithms to show that a Quadratic Discriminant Analysis (precision=99.33%, recall=99.26%, and F1-score=99.26%) outperforms three other machine learning classifiers, i.e., a Linear Discriminant Analysis, a Support Vector Machines, and a Random Forest, as well as existing recognizers from the literature, to accurately recognize such gestures without the need to call for Deep Learning. Through a performance analysis, we demonstrate that TapStrapGest is a versatile and admissible solution for ring-based multi-finger gesture interaction, opening avenues for "eyes-free" or "screen-free" human-computer interaction in various domains.

5 September 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Guillem Cornella-BarbaGuillem Cornella-Barba
Guillem Cornella-Barba
NGNatanya Gunn
Natanya Gunn
VCVicky Chan
Vicky Chan
DRDavid Reinkensmeyer
David Reinkensmeyer
JHJay J. Han
Jay J. Han
Reachable workspace (RWS) quantifies the three-dimensional space accessible to the upper limb, but its relationship with real-world arm use after stroke remains unclear. This study examined associations between camera-based RWS and smartwatch-derived movement behavior in 14 individuals with chronic stroke. Relative surface area (RSA) was measured at baseline, after which participants wore a smartwatch on the affected arm. Smartwatch data were summarized using Gross Movement and Activity Count (GMAC), representing the proportion of wear time spent in active arm movement within a functional workspace, and Active and Diverse Exploratory Movement (ADEM), representing the proportion of wear time that was active and diverse. Clinical outcomes included the Box and Block Test (BBT), Upper-Extremity Fugl-Meyer Assessment (UEFM), and Motor Activity Log (MAL). Total RSA and several workspace regions were reduced in the paretic compared with the nonparetic limb. Greater total RSA was significantly associated with ADEM (ρ = 0.66, p = 0.01), while its association with GMAC was numerically weaker and non-significant (ρ = 0.47, p = 0.09). RSA was also significantly associated with BBT, UEFM, and MAL, with correlations ranging from ρ = 0.57 to 0.76. These findings link camera-based RWS with wrist-worn measures of real-world arm performance after stroke.