Haidar Alalawi

Dr. Haidar Alalawi

Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
Yousif A. Al-DulaijanYousif A. Al-Dulaijan
Yousif A. Al-Dulaijan
LALeenah Alsulaimi
Leenah Alsulaimi
RAReema Alotaibi
Reema Alotaibi
AAAreej Alboainain
Areej Alboainain
HAHaidar Alalawi
Haidar Alalawi
Mohammed GadMohammed Gad
Mohammed Gad
The effect of printing parameters on the surface characteristics of three-dimensional (3D)-printed denture base resins (DBRs) is neglected. Therefore, this study investigated the effect of printing orientation and post-curing time on the surface roughness and hardness. One conventional heat-polymerized (HP) resin and two 3D-printing resins (NextDent (ND) and ASIGA (AS)) were used to fabricate a total of 250-disc (10 × 2.5 mm) specimens. ND and AS specimens were printed with different orientations (0-, 45-, and 90-degree) and each orientation group was subjected to four post-curing times (30, 60, 90, 120 min). Printed specimens were thermo-cycled (10,000 cycles) followed by the measuring of surface roughness (Profilometer (Ra)) and hardness (a Vickers hardness (VH)). ANOVA and post hoc tests were used for data analysis (α = 0.05) at significant levels. AS and ND showed no significant changes in Ra when compared with HP (p ˃ 0.05), except the 45-degree orientation (AS/90 min and AS/120 min) significantly increased surface roughness (p ˂ 0.001). There was no significant difference in Ra with different orientations and post-curing time for both materials AS and ND (p ˃ 0.05). Compared with HP, 3D-printed DBRs showed low VH values (p ˂ 0.001). For AS, 90-degree orientation showed a significant decrease in VH at 60, 90, and 120 min when compared with 0- and 45-degree orientation (p ˂ 0.001), while ND showed no significant difference in VH with different printing orientations (p ˃ 0.05). The VH of AS and ND improved when increasing post-curing time to 120 min (p ˂ 0.001), and the printing orientations and post-curing time did not affect the Ra of 3D-printed DBRs.

11 November 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Reem AbualsaudReem Abualsaud
Reem Abualsaud
HAHaidar Alalawi
Haidar Alalawi
Precise fit of a crown and accurate reproduction of the digital design are paramount for successful treatment outcomes and preservation of clinician and technician time. The study aimed to compare the internal fit, marginal adaptation, precision, and trueness of 3D-printed zirconia crowns compared to their milled counterpart. A total of 20 monolithic 3 mol% yttria stabilized-zirconia crowns (n = 10) were made using computer-assisted design (CAD) followed by additive (3D-printed) and subtractive (milled) manufacturing. Digital scanning of the master die with and without a fit checker followed by image superimposition, and analysis was performed to evaluate internal and marginal adaptation in four areas (occlusal, axial, marginal, and overall). ISO 12836:2015 standard was followed for precision and trueness evaluation. Statistical analysis was achieved using a t-test at α = 0.05. Internal fit and marginal adaptation revealed no significant difference between the two test groups (p > 0.05). The significant difference in trueness (p < 0.05) was found between the two groups in three areas (occlusal, axial, and internal). The best and worst trueness values were seen with 3D-printed crowns at occlusal (8.77 ± 0.89 µm) and Intaglio (23.90 ± 1.60 µm), respectively. The overall precision was statistically better (p < 0.05) in the 3D-printed crowns (9.59 ± 0.75 µm) than the milled (17.31 ± 3.39 µm). 3D-printed and milled zirconia crowns were comparable to each other in terms of internal fit and marginal adaptation. The trueness of the occlusal and axial surfaces of 3D-printed crowns was better, whereas the trueness of fitting surface of milled crowns was better. 3D-printed crowns provided a higher level of precision than milled crowns. Although the internal and marginal fit of both production techniques were comparable, 3D printing of zirconia produced more precise crowns.

8 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
Reem AbualsaudReem Abualsaud
Reem Abualsaud
MAMaissan Abussaud
Maissan Abussaud
YAYara Assudmi
Yara Assudmi
GAGhadah Aljoaib
Ghadah Aljoaib
AKAbrar Khaled
Abrar Khaled
Mohammed GadMohammed Gad
Mohammed Gad
The objective of this study is to examine the physiomechanical and surface properties of 3D-printed zirconia in comparison to milled zirconia. A total of 80 disc-shaped (14 × 1.5 ± 0.2 mm) specimens (20 milled and 60 3D-printed (at three different orientations; horizontal, vertical, and tilted)) were manufactured from 3-mol% yttria-stabilized tetragonal zirconia. Five specimens per group were evaluated for crystalline phase, grain size, density, porosity, surface roughness, wettability, microhardness, and SEM analysis of the surface. Biaxial flexural strength (BFS) was measured (n = 15) followed by Weibull analysis and SEM of fractured surfaces. Statistical analysis was performed using one-way ANOVA and Tukey’s post hoc test at α = 0.05. All groups showed a predominant tetragonal phase, with a 450 nm average grain size. There was no significant difference between groups with regards to density, porosity, and microhardness (p > 0.05). The tilted group had the highest surface roughness (0.688 ± 0.080 µm), significantly different from the milled (p = 0.012). The horizontal group presented the highest contact angle (89.11 ± 5.22°), significantly different from the milled and tilted (p > 0.05). The BFS of the milled group (1507.27 ± 340.10 MPa) was significantly higher than all other groups (p < 0.01), while vertical and tilted had a similar BFS that was significantly lower than horizontal (p < 0.005). The highest and lowest Weibull modulus were seen with tilted and milled, respectively. Physical properties of all groups were comparable. The surface roughness of the tilted group was higher than milled. The horizontal group had the highest hydrophobicity. Printing orientations influenced the flexural strength of 3D-printed zirconia. Clinical implications: This study demonstrates how the printing orientation affects the physiomechanical characteristics of printed zirconia.

31 March 2023 in Polymers
Verified
Journal Article
Open access
PDF file
RAReem I AlKhateeb
Reem I AlKhateeb
HAHadeel S. Algaoud
Hadeel S. Algaoud
RARand Baher AlDamanhori
Rand Baher AlDamanhori
RARand R. Alshubaili
Rand R. Alshubaili
HAHaidar Alalawi
Haidar Alalawi
Mohammed GadMohammed Gad
Mohammed Gad
The fracture resistance of 3-unit interim fixed dental prostheses (IFDPs) fabricated using digital light processing (DLP) additive technology with different printing parameters is neglected. Therefore, this study investigates the effect of different printing orientations and different post-curing times on the fracture resistance of 3-unit IFDPs fabricated from two three-dimensional (3D) printed resins, NextDent, C&B (CB), ASIGA, and DentaTOOTH. A 3-unit dye was scanned, and an IFDP was designed. A total of 300 specimens (150/materials, n = 10) were printed and divided into three groups according to printing orientations (0°, 45°, 90°) per material. Each orientation was subdivided into five groups (n = 10) considering the post-curing time (green state as control, 30, 60, 90, and 120 min). All specimens underwent thermocycling (5000 cycles). Each specimen was fitted onto the die and loaded until fracture using a universal testing machine with a loading rate of 1 m/min. Data were analyzed using ANOVA and post hoc Tukey test (α = 0.05). The result showed that printing orientation had a significant effect on the fracture load for both ASIGA and NextDent materials (p < 0.05). The highest fracture load was recorded with 45° orientation, followed by 0° orientation and 90° orientation showed the lowest values per respective post-curing time. Post-curing time increased the fracture load (p < 0.05). Post-curing time had a positive effect on the fracture load. As the post-curing time increased, the fracture resistance load increased (p < 0.05), with 90 and 120 min showing the highest fracture load. The 0° and 45° printing orientations have a high fracture load for 3D-printed IFDPs, and an increased post-curing time is recommended.

20 January 2023 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
Mohammed GadMohammed Gad
Mohammed Gad
HAHaidar Alalawi
Haidar Alalawi
Sultan AkhtarSultan Akhtar
Sultan Akhtar
RARaghad Al-Ghamdi
Raghad Al-Ghamdi
RARahaf Alghamdi
Rahaf Alghamdi
FAFaisal al-Qarni
Faisal al-Qarni
Objectives With advanced technology for complete denture fabrication, there is a lack of knowledge on the mechanical behavior of three-dimensional (3D) printed teeth despite the development of complete denture fabrication technologies. This study aimed to compare different types of 3D-printed teeth in terms of wear and fracture resistance in comparison to control prefabricated denture teeth. Materials and Methods One prefabricated tooth was selected and fixed in a resin holder and half of the tooth remained in anatomic form, while the other half was flattened for the wear test. One from each type was scanned and then printed with different resins; Asiga (DentaTOOTH, Asiga, Alexandria 2015,NSW, Australia), FormLabs (Denture Base LP, FormLabs, Berlin, Germany), and NextDent (NextDent C&B MFH, NextDent B.V., Soesterberg, the Netherlands) according to manufacturer recommendations. A total of 60 specimens (20/resin, n = 10) were thermo cycled (5,000 cycles) and wear test samples were further subjected to cyclic loading (1,70,000 cycles) in a chewing simulator machine CS-4.2 (SD Mechatronik GmbH, Germany). The fracture strength of anatomic teeth was measured using a universal testing machine (Instron model 5965, Massachusetts, United States), while Geomagic Control X software was used to assess the amount of wear of flattened teeth. Statistical analyses were performed with one-way analysis of variance with Tukey's post hoc test at significance level of α = 0.05. Results NextDent specimens showed the greatest volume loss, whereas FormLabs specimens showed the least volume loss. Comparing NextDent specimens to FromLabs specimens, FromLabs showed statistically significantly less volume loss (p < 0.001). No other group pairs differed significantly from one another in terms of volume loss (p > 0.06). Conclusion 3D-printed denture teeth showed comparable strength and wear resistance with the prefabricated denture teeth and were suitable for long-term clinical usage except for NextDent that significantly showed the lowest fracture resistance.

27 April 2022 in Journal of Prosthodontics
Verified
Journal Article
Closed access
Mohammed GadMohammed Gad
Mohammed Gad
RARahaf Alghamdi
Rahaf Alghamdi
RARaghad Al‐Ghamdi
Raghad Al‐Ghamdi
AAAlaa Al‐Jefri
Alaa Al‐Jefri
Sultan AkhtarSultan Akhtar
Sultan Akhtar
FAFaisal al-Qarni
Faisal al-Qarni