DongHee CHOI

Prof. DongHee CHOI

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2020 in IEEE Access
Verified
Journal Article
Open access
KYKipo Yoon
Kipo Yoon
DongHee CHOIDongHee CHOI
DongHee CHOI
SLSoo Hyoung Lee
Soo Hyoung Lee
Jung-Wook PARKJung-Wook PARK
Jung-Wook PARK
The implementation of distributed generation (DG) becomes more common while causing a challenge to maintain the voltage stability in a power system. The optimal placement of multiple DGs in a planning stage can effectively solve this problem. In many cases, the best placement has been determined by the small-signal study like the modal analysis. However, it is acceptable only if the linearization of large-scale nonlinear power system is accurate. To overcome this, this paper proposes the new optimal placement algorithm for multiple DGs based on the model-free Lyapunov exponent estimation to maintain the voltage of system stable. In other words, the individual Lyapunov exponents of all buses are firstly estimated to determine the candidates for optimal placement of DGs. Then, the maximum Lyapunov exponent for each candidate is calculated to decide which bus is the best place to improve the voltage stability of system. Several time-domain simulation studies are carried out to verify the effectiveness of proposed algorithm. In particular, its performance is compared with that of the conventional method. The results show that the optimal placement of multiple DGs determined by the proposed algorithm improves the voltage stability of system much more effectively.

24 May 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SLSoo Hyoung Lee
Soo Hyoung Lee
DongHee CHOIDongHee CHOI
DongHee CHOI
Jung-Wook PARKJung-Wook PARK
Jung-Wook PARK
Inertia-Free Stand-Alone Microgrid, Part II: Inertia Control and Stability with PMSG Wind Turbine System

26 January 2022 in IEEE Access
Verified
Journal Article
Open access
SungHoon LimSungHoon Lim
SungHoon Lim
DongHee CHOIDongHee CHOI
DongHee CHOI
SLSoo Hyoung Lee
Soo Hyoung Lee
CKChongqing Kang
Chongqing Kang
Jung-Wook PARKJung-Wook PARK
Jung-Wook PARK
The high penetration of converter-based distributed generations (DGs) to power system can give rise to the lack of rotational inertia while replacing the conventional synchronous generators (SGs), which provide the primary frequency reserve (PFR) in power systems. As the result, the decrease in PFR aggravates the frequency stability. To overcome this problem, the droop coefficients of governors in the remaining conventional SGs must be re-determined newly and properly. This paper proposes a new solution based on the grey wolf optimization (GWO) method to optimally select the droop coefficients of SG governors in the low-inertia large-scale power system due to the high penetration of renewables. The proposed solution is very effective for reducing the computational effort significantly, and it is able to recover not only the steady-state but also the transient frequency stability. To verify the effectiveness of proposed optimization solution based on the GWO method, several case studies are carried out on the practical Korea electric power system with the penetration of wind power plants of 4 GW.

25 June 2025 in Batteries
Verified
Journal Article
Open access
PDF file
ZCZineb Cabrane
Zineb Cabrane
DongHee CHOIDongHee CHOI
DongHee CHOI
SLSoo Hyoung Lee
Soo Hyoung Lee
The need for electrical energy is dramatically increasing, pushing researchers and industrial communities towards the development and improvement of microgrids (MGs). It also encourages the use of renewable energies to benefit from available sources. Thereby, the implementation of a photovoltaic (PV) system with a hybrid energy storage system (HESS) can create a standalone MG. This paper presents an MG that uses photovoltaic energy as a principal source. An HESS is required, combining batteries and supercapacitors. This MG responds “insure” both alternating current (AC) and direct current (DC) loads. The batteries and supercapacitors have separate parallel connections to the DC bus through bidirectional converters. The DC loads are directly connected to the DC bus where the AC loads use a DC-AC inverter. A control strategy is implemented to manage the fluctuation of solar irradiation and the load variation. This strategy was implemented with a new logic control based on Boolean analysis. The logic analysis was implemented for analyzing binary data by using Boolean functions (‘0’ or ‘1’). The methodology presented in this paper reduces the stress and the faults of analyzing a flowchart and does not require a large concentration. It is used in this paper in order to simplify the control of the EMS. It permits the flowchart to be translated to a real application. This analysis is based on logic functions: “Or” corresponds to the addition and “And” corresponds to the multiplication. The simulation tests were executed at Tau = 6 s of the low-pass filter and conducted in 60 s. The DC bus voltage was 400 V. It demonstrates that the proposed management strategy can respond to the AC and DC loads.

15 July 2025 in IEEE Access
Verified
Journal Article
Open access
SLSoo Hyoung Lee
Soo Hyoung Lee
DongHee CHOIDongHee CHOI
DongHee CHOI
Seung-Mook BaekSeung-Mook Baek
Seung-Mook Baek
So far, the short circuit ratio (SCR) has been widely used to assess grid robustness at inverter points of interconnection. However, its mathematical and geometric foundations have not been fully established, and its applicability across various X/R ratios and power factors remains an open question. This paper provides a geometric interpretation of the SCR based on the two-dimensional direct-quadrature axis framework from the perspective of voltage stability. The analysis incorporates the grid’s equivalent impedance, specifically accounting for the X/R ratio, as well as the inverter’s power factor and the reactive power contribution of shunt filter capacitors. The proposed method is validated through multiple case studies conducted under diverse conditions using an electromagnetic transient (EMT) model derived from a real power system. Simulations are performed with the Power System Computer Aided Design/Electromagnetic Transient including DC (PSCAD/EMTDCTM) platform.

15 July 2021 in IEEE Access
Verified
Journal Article
Open access
SLSoo Hyoung Lee
Soo Hyoung Lee
DongHee CHOIDongHee CHOI
DongHee CHOI
Jung-Wook PARKJung-Wook PARK
Jung-Wook PARK
Recently, renewable energy has received considerable attention worldwide due to environmental problems such as climate change. However, there are still many problems to be solved to increase the penetration level of renewable energy sources in a power system. Above all, a power system with a high renewable penetration level requires an entirely novel operational strategy and control approach to achieve reliable operation by considering the intermittency of variable renewable energy sources. This paper proposes power-sensitivities-based indirect voltage control of renewable energy generators with power constraints. The proposed method realizes seamless control of the voltage by compensating with the reactive power if the real power of the distributed generator (DG) is insufficient due to its intermittency. To achieve the proposed method, the real and reactive power references of DGs are initially operated based on the power sensitivities between generation and loads if all the DGs operate within the power constraints. However, if at least one of the DGs reaches its constraint limit, the references can be modified using other sensitivities between real and reactive power generation enabling indirect voltage control of DGs. Therefore, a high level of renewable penetration in power systems can be accomplished with the proposed method. The proposed method is verified with several case studies that are based on a microgrid with practical data from a real island power system. Verification is carried out using the power system computer aided design and electromagnetic transient including DC (PSCAD/EMTDC™) simulation software.