Henrik Feuk

Mr. Henrik Feuk

Lund University, Lund, Sweden
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Proceedings of the Combustion Institute
Verified
Journal Article
Open access
WWWubin Weng
Wubin Weng
HFHenrik Feuk
Henrik Feuk
SLShen Li
Shen Li
MRMattias Richter
Mattias Richter
MAMarcus Alden
Marcus Alden
ZLZhongshan Li
Zhongshan Li

13 May 2021 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
HFHenrik Feuk
Henrik Feuk
DSDavid Sanned
David Sanned
MRMattias Richter
Mattias Richter
MAMarcus Aldén
Marcus Aldén
This study investigates photomultiplier tube (PMT) nonlinearities, relevant for lifetime phosphor thermometry, at various decay times to assess and minimize the impact on temperature measurement accuracy. The focus is single-shot measurements performed in harsh environments where phosphor signal attenuation often is a concern. The sensitivity of decay time measurements to changing phosphorescence intensity is therefore investigated. The experimental results show that for the studied phosphors and detectors, shorter decay times between 20 ns and 6 µs, saturation effects in the PMTs decreased the measured decay time with increasing signal attenuation. For longer phosphorescence decay times, in the millisecond regime, nonlinearity effects led to an increase in the measured decay time with increasing signal attenuation. The specific detector nonlinearity response will vary among detectors, but the introduced methodology for detector analysis is a useful resource for assessing and improving accuracy in lifetime phosphor thermometry measurements.

18 October 2024 in Carbon
Verified
Journal Article
Open access
TRTânia M. Ribeiro
Tânia M. Ribeiro
TMTiago E.C. Magalhães
Tiago E.C. Magalhães
BKBohdan Kulyk
Bohdan Kulyk
ACAlexandre F. Carvalho
Alexandre F. Carvalho
SNSebastian Nilsson
Sebastian Nilsson
HCHelder Crespo
Helder Crespo

1 December 2021 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
HFHenrik Feuk
Henrik Feuk
SNSebastian Nilsson
Sebastian Nilsson
MAMarcus Aldén
Marcus Aldén
MRMattias Richter
Mattias Richter
Photomultiplier tube (PMT) nonlinearities relevant for single shot high-speed lifetime phosphor thermometry were investigated by simulating decay curves with a light emitting diode (LED) at repetition rates between 1 Hz and 10 kHz. The PMT gain, LED decay time, and background radiant flux were also varied to investigate their impact on the measured decay time error. Errors in the measured decay time due to nonlinear PMT performance lead to temperature measurement errors; therefore, having the measured decay time sensitive to only phosphor temperature is highly valuable for more reliable temperature measurements. Photocathode bleaching had a significant impact on the signal level linearity for PMTs with excitation frequency in the kHz regime but had a smaller impact on the decay time error. Space charge effects were most noticeable at high radiant flux levels and high repetition rates. Strong background radiant flux may lead to decay time errors, and a gateable photocathode could be an effective method to reduce decay time errors. The best decay time measurement configuration to maximize precision without sacrificing accuracy is to use PMT gain in the recommended range and the highest radiant flux where the PMT response is still linear. The degree of nonlinearity in the PMT response is partly detector dependent; therefore, the results in this work may differ among detectors; however, the analysis presented in this work provides guidelines for improving the temperature accuracy of kHz lifetime phosphor thermometry measurements.

HFHenrik Feuk
Henrik Feuk
FPFrancesco Pignatelli
Francesco Pignatelli
ASArman Subash
Arman Subash
RBRuike Bi
Ruike Bi
RSRobert-Zoltan Szasz
Robert-Zoltan Szasz
MRMattias Richter
Mattias Richter
The surface temperature of a burner nozzle using three different pilot hardware configurations was measured using lifetime phosphor thermometry with the ZnS:Ag phosphor in a gas turbine model combustor designed to mimic the Siemens DLE (Dry Low Emission) burner. The three pilot hardware configurations included a non-premixed pilot injection setup and two partially premixed pilot injections where one had a relatively higher degree of premixing. For each pilot hardware configuration, the combustor was operated with either methane or hydrogen-enriched methane (H2/CH4: 50/50 in volume %). The local heating from pilot flames was much more significant for hydrogen-enriched methane compared with pure methane due to the pilot flames being in general more closely attached to the pilot nozzles with hydrogen-enriched methane. For the methane fuel, the average surface temperature of the burner nozzle was approximately 40 K higher for the partially premixed pilot injection configuration with a lower degree of mixing as compared to the non-premixed pilot injection configuration. In contrast, with the hydrogen-enriched methane fuel, the differences in surface temperature between the different pilot injection hardware configurations were much smaller due to the close-to-nozzle frame structure.

4 July 2022 in Journal of Luminescence
Verified
Journal Article
Open access
HFHenrik Feuk
Henrik Feuk
SNSebastian Nilsson
Sebastian Nilsson
MRMattias Richter
Mattias Richter