Noriko Hiraishi

Dr. Noriko Hiraishi

Tokyo Medical and Dental University, Tokyo, Japan
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in International Dental Journal
Verified
Journal Article
Closed access
Irene Shuping ZhaoIrene Shuping Zhao
Irene Shuping Zhao
SGSherry Shiqian Gao
Sherry Shiqian Gao
Noriko HiraishiNoriko Hiraishi
Noriko Hiraishi
MBMichael Francis Burrow
Michael Francis Burrow
Tammy DuangthipTammy Duangthip
Tammy Duangthip
Chun Hung ChuChun Hung Chu
Chun Hung Chu

1 December 2005 in Biomaterials
Verified
Journal Article
Open access
CYCynthia K.Y. Yiu
Cynthia K.Y. Yiu
EPEdna L. Pashley
Edna L. Pashley
Noriko HiraishiNoriko Hiraishi
Noriko Hiraishi
NKNigel M. King
Nigel M. King
CGCecilia Goracci
Cecilia Goracci
FTFranklin R. Tay
Franklin R. Tay
This study examined the extent of organic solvent and water retention in comonomer blends with different hydrophilicity (Hoy's solubility parameter for hydrogen bonding, delta(h)) after solvent evaporation, and the extent of tracer penetration in polymerised films prepared from these resins. For each comonomer blend, adhesive/solvent mixtures were prepared by addition of (1) 50 wt% acetone, (2) 50 wt% ethanol, (3) 30 wt% acetone and 20 wt% water and (4) 30 wt% ethanol and 20 wt% water. The mixtures were placed in glass wells and evaporated for 30-60s for acetone-based resins, and 60-120 s for ethanol-based resins. The weight of the comonomer mixtures was measured before and after solvent evaporation. Resin films were prepared for transmission electron microscopy (TEM) after immersion in ammonical silver nitrate. The percentages of solvent and water retained in the comonomer mixtures, and between the acetone and ethanol groups were measured gravimetrically and were statistically compared. In comonomer-organic solvent mixtures, the percentage of solvent retained in acetone and ethanol-based mixtures increased significantly with hydrophilicity of the comonomer blends (P < 0.05). In resin-organic solvent-water mixtures, significantly more solvent and water were retained in the ethanol-based mixtures (P < 0.0001), when compared to acetone-based mixtures after 60s of air-drying. TEM revealed residual water being trapped as droplets in resin films containing acetone and water. Water-filled channels were seen along the film periphery of all groups and throughout the entire resin films containing ethanol and water. The addition of water to comonomer-ethanol mixtures results in increased retention of both ethanol and water because both solvents can hydrogen bond to the monomers.

1 September 2013 in Journal of Dentistry
Verified
Journal Article
Closed access
DEDon Jeevanie Epasinghe
Don Jeevanie Epasinghe
CYCynthia Kar Yung Yiu
Cynthia Kar Yung Yiu
MBMichael Francis Burrow
Michael Francis Burrow
Noriko HiraishiNoriko Hiraishi
Noriko Hiraishi
FTFranklin Russell Tay
Franklin Russell Tay

1 October 2013 in Dental Materials
Verified
Journal Article
Closed access
Noriko HiraishiNoriko Hiraishi
Noriko Hiraishi
RSRyohei Sono
Ryohei Sono
Md Sofiqul IslamMd Sofiqul Islam
Md Sofiqul Islam
CYCynthia Yiu
Cynthia Yiu
Hiroyuki NakamuraHiroyuki Nakamura
Hiroyuki Nakamura
JTJunji Tagami
Junji Tagami

1 July 2005 in Journal of Dental Research
Verified
Journal Article
Open access
PDF file
Noriko HiraishiNoriko Hiraishi
Noriko Hiraishi
NNN. Nishiyama
N. Nishiyama
KIK. Ikemura
K. Ikemura
JYJ.Y.Y. Yau
J.Y.Y. Yau
NKN.M. King
N.M. King
FTF.R. Tay
F.R. Tay
Water is required to ionize acid resin monomers for demineralization of tooth substrates. We tested the null hypothesis that altering the water concentration in two-step self-etching primers has no effect on their aggressiveness and bonding efficacy to dentin. Five experimental self-etching primers were prepared with resin-water-ethanol volume ratios of 9-0-1, 8-1-1, 7-2-1, 5-4-1, and 3-6-1. They were applied to smear-layer-covered dentin, followed by a bonding resin and composite build-ups for microtensile bond testing and TEM examination of tracer penetration. Increasing water concentration from 0–60 vol% improved acidic monomer ionization that was manifested as increasing hybrid layer thickness. However, significantly higher bond strength was observed in the 7-2-1 group, with minimal nanoleakage in the corresponding hybrid layer. When self-etching primers are formulated, a balance must be achieved to provide sufficient water for adequate ionization of the acidic monomers, without lowering the resin concentration too much, to optimize their bonding efficacy to dentin.

1 June 2010 in Journal of Endodontics
Verified
Journal Article
Closed access
Noriko HiraishiNoriko Hiraishi
Noriko Hiraishi
CYCynthia K.Y. Yiu
Cynthia K.Y. Yiu
NKNigel M. King
Nigel M. King
JTJunji Tagami
Junji Tagami
FTFranklin R. Tay
Franklin R. Tay