Hongwu Wang

Dr. Hongwu Wang

University of Florida, Gainesville, Florida, USA
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2010 in American Journal of Physical Medicine & Rehabilitation
Verified
Journal Article
Closed access
SBSteven W. Brose
Steven W. Brose
DWDouglas J. Weber
Douglas J. Weber
BSBen A. Salatin
Ben A. Salatin
GGGarret G. Grindle
Garret G. Grindle
Hongwu WangHongwu Wang
Hongwu Wang
RCRory A. Cooper
Rory A. Cooper
Robotic assistive devices are used increasingly to improve the independence and quality of life of persons with disabilities. Devices as varied as robotic feeders, smart-powered wheelchairs, independent mobile robots, and socially assistive robots are becoming more clinically relevant. There is a growing importance for the rehabilitation professional to be aware of available systems and ongoing research efforts. The aim of this article is to describe the advances in assistive robotics that are relevant to professionals serving persons with disabilities. This review breaks down relevant advances into categories of Assistive Robotic Systems, User Interfaces and Control Systems, Sensory and Feedback Systems, and User Perspectives. An understanding of the direction that assistive robotics is taking is important for the clinician and researcher alike; this review is intended to address this need.

1 July 2013 in The Journal of Spinal Cord Medicine
Verified
Journal Article
Closed access
CCCheng-Shiu Chung
Cheng-Shiu Chung
Hongwu WangHongwu Wang
Hongwu Wang
RCRory A. Cooper
Rory A. Cooper
Context The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. Methods We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System – PITTCat. Results Twenty relevant studies were identified. Conclusion Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators.

1 December 2008 in Medical Engineering & Physics
Verified
Journal Article
Closed access
RCRory A. Cooper
Rory A. Cooper
BDBrad Dicianno
Brad Dicianno
BBBambi Brewer
Bambi Brewer
ELEdmund LoPresti
Edmund LoPresti
DDDan Ding
Dan Ding
Hongwu WangHongwu Wang
Hongwu Wang
Globally, the number of people older than 65 years is anticipated to double between 1997 and 2025, while at the same time the number of people with disabilities is growing at a similar rate, which makes technical advances and social policies critical to attain, prolong, and preserve quality of life. Recent advancements in technology, including computation, robotics, machine learning, communication, and miniaturization of sensors have been used primarily in manufacturing, military, space exploration, and entertainment. However, few efforts have been made to utilize these technologies to enhance the quality of life of people with disabilities. This article offers a perspective of future development in seven emerging areas: translation of research into clinical practice, pervasive assistive technology, cognitive assistive technologies, rehabilitation monitoring and coaching technologies, robotic assisted therapy, and personal mobility and manipulation technology.

1 January 2010 in Journal of Rehabilitation Research and Development
Verified
Journal Article
Closed access
HLHsin-Yi Liu
Hsin-Yi Liu
JPJonathan Pearlman
Jonathan Pearlman
RCRosemarie Cooper
Rosemarie Cooper
EHEun-Kyoung Hong
Eun-Kyoung Hong
Hongwu WangHongwu Wang
Hongwu Wang
RCRory A. Cooper
Rory A. Cooper
Previous studies found that select titanium ultralight rigid wheelchairs (TURWs) had fewer equivalent cycles and less value than select aluminum ultralight folding wheelchairs (AUFWs). The causes of premature failure of TURWs were not clear because the TURWs had different frame material and design than the AUFWs. We tested 12 aluminum ultralight rigid wheelchairs (AURWs) with similar frame designs and dimensions as the TURWs using the American National Standards Institute/Rehabilitation Engineering and Assistive Technology Society of North America and International Organization for Standardization wheelchair standards and hypothesized that the AURWs would be more durable than the TURWs. Across wheelchair models, no significant differences were found in the test results between the AURWs and TURWs, except in their overall length. Tire pressure, tube-wall thickness, and tube manufacturing were proposed to be the factors affecting wheelchair durability through comparison of the failure modes, frames, and components. The frame material did not directly affect the performance of AURWs and TURWs, but proper wheelchair manufacture and design based on mechanical properties are important.

14 June 2012 in Proceedings of the IEEE
Verified
Journal Article
Closed access
RCRory A. Cooper
Rory A. Cooper
GGG. G. Grindle
G. G. Grindle
JVJ. J. Vazquez
J. J. Vazquez
JXJ. Xu
J. Xu
Hongwu WangHongwu Wang
Hongwu Wang
SBS. Beach
S. Beach
The ability to perform activities of daily living and mobility-related activities of daily living are substantial indicators of one's ability to live at home and to participate in one's community. Technologies to assist with mobility and manipulation are among the most important tools that clinicians can provide to people with disabilities to promote independence and community participation. For people with severe disabilities involving both the upper and lower extremities, there are few systems that provide practical and coordinated assistance with mobility and manipulation tasks. The personal mobility and manipulation appliance (PerMMA) was created in response to goals set forth by a team of clinicians and people with disabilities.

21 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Hongwu WangHongwu Wang
Hongwu Wang
RCRaghuveer Chandrashekhar
Raghuveer Chandrashekhar
JRJosiah Rippetoe
Josiah Rippetoe
MGMustafa Ali Ghazi
Mustafa Ali Ghazi
In this review, we present a narrative synthesis of studies on the use of focal muscle vibration (FMV) in stroke rehabilitation with a focus on vibration device, parameters, and protocols. A search was conducted via PubMed, SCOPUS, PEDro, REHABDATA, and Web of Science using the keywords “stroke and focal vibration” or “focal muscle vibration”. Inclusion and exclusion criteria to select the articles were determined. Twenty-two articles involving FMV and stroke were included in this review. Eight different vibration devices were used in the 19 articles that reported the vibration apparatuses. The vibration frequencies ranged from 30 Hz to 300 Hz with amplitudes ranging from 0.01 mm to 2 mm. The vibration treatment frequency ranged from a single treatment to 5 days/week. The session duration ranged from 14 s to 60 min/session with a duration of a single treatment to eight weeks. Twenty different muscles were targeted with 37 different outcome measures used to assess the effects of FMV. The clinical applications of FMV were not confirmed based on available evidence. More research is needed to improve the FMV technology, guide the selection of vibration parameters, optimize the vibration dosage, and develop standardized protocols for FMV therapy in patients with stroke.