Hsin-Fu Lin

Dr. Hsin-Fu Lin

National Taiwan University
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2022 in Cells
Verified
Journal Article
Open access
PDF file
SKSandhya Kresnajati
Sandhya Kresnajati
YLYi-Yuan Lin
Yi-Yuan Lin
Toby MündelToby Mündel
Toby Mündel
JBJeffrey R. Bernard
Jeffrey R. Bernard
HLHsin-Fu Lin
Hsin-Fu Lin
YLYi-Hung Liao
Yi-Hung Liao
Arterial stiffness is a reliable independent predictor of cardiovascular events. Exercise training might enhance arterial compliance through improved metabolic health status. Different modes of exercise may have different effects on arterial stiffness. However, the interactions among different modes of exercise on endothelial senescence, the development of arterial vascular stiffness, and the associated molecular mechanisms are not completely understood. In this narrative review, we evaluate the current evidence focusing on the effects of various exercise modes on arterial stiffness and vascular health, and the known underlying physiological mechanisms are discussed as well. Here, we discuss the most recent evidence of aerobic exercise, high-intensity interval training (HIIT), and resistance exercise (RE) on arterial stiffness and endothelial senescence in physiological and cellular studies. Indeed, aerobic, HIIT, and progression RE-induced arterial compliance may reduce arterial stiffness by effectively promoting nitric oxide (NO) bioavailability and reducing endothelial senescence. However, the transient increase in inflammation and sympathetic activation may contribute to the temporary elevation in arterial stiffness following whole-body high-intensity acute resistance exercise.

Sri SumartiningsihSri Sumartiningsih
Sri Sumartiningsih
HLHsin-Fu Lin
Hsin-Fu Lin
JLJung-Charng Lin
Jung-Charng Lin
This study aimed to examine the exercise-induced heart rate response (HRR) and heart rate variability (HRV) in subjects caused by inhaling smoke from tobacco cigarettes (TC) and aerosolized vapor from electronic nicotine dispensing systems (ENDS) (commonly referred to as e-cigarettes (EC)). A randomized crossover study recruited 24 young adult male smokers with an average age of 23 years and with a smoking habit of at least two years. Heart rate response was recorded after a maximal multistage shuttle 20 m run test (MMST) under three different levels of nicotine: Control 0 mg nicotine of EC (C), 3 mg nicotine of EC (3EC), and 3 mg nicotine of TC (3TC). HRV was evaluated based on the beat-to-beat time interval during the running test. The results showed no statistically significant differences in the run time to exhaustion under the three conditions (C: 398 ± 151 s; 3EC: 399 ± 160 s; 3TC: 381 ± 150 s). Exercise-induced HRR was significantly attenuated under the TC condition (p < 0.05). Intriguingly, the HRV standard deviation of normal-to-normal intervals (SDNN) during exercise significantly increased under 3EC and 3TC. The results showed that a significant acute autonomic cardiac modulation during exercise is induced by an acute episode of EC and TC smoking.

5 January 2026 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
RKRajat Subhra Karmakar
Rajat Subhra Karmakar
HLHsin-Fu Lin
Hsin-Fu Lin
CHChia-Ching Huang
Chia-Ching Huang
JHJhih-Fong Huang
Jhih-Fong Huang
JCJui-I Chao
Jui-I Chao
Yen-Wen LuYen-Wen Lu
Yen-Wen Lu

27 December 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
RKRajat Subhra Karmakar
Rajat Subhra Karmakar
HLHsin-Fu Lin
Hsin-Fu Lin
JHJhih-Fong Huang
Jhih-Fong Huang
Jui-I ChaoJui-I Chao
Jui-I Chao
YLYing-Chih Liao
Ying-Chih Liao
Yen-Wen LuYen-Wen Lu
Yen-Wen Lu
An origami-based tactile sensory ring utilizing multilayered conductive paper substrates presents an innovative approach to wearable health applications. By harnessing paper’s flexibility and employing origami folding, the sensors integrate structural stability and self-packaging without added encapsulation layers. Knot-shaped designs create loop-based systems that secure conductive paper strips and protect sensing layers. Demonstrating a sensitivity of 3.8 kPa−1 at subtle pressures (0–0.05 kPa), the sensors detect both minimal stimuli and high-pressure inputs. Electrical modeling of various origami configurations identifies designs with optimized performance with a pentagon knot offering higher sensitivity to support high-sensitivity needs. Meanwhile a square knot provides greater precision and quicker recovery, balancing sensitivity and stability for real-time feedback devices. The enhanced elastic modulus from folds remains within human skin’s elasticity range, ensuring comfort. Applications include grip strength monitoring and pulse rate detection from the thumb, capturing pulse transit time (PTT), an essential cardiovascular biomarker. This design shows the potential of origami-based tactile sensors in creating versatile, cost-effective wearable health monitoring systems.

1 January 2021 in Artery Research
Verified
Journal Article
Open access
PDF file
HLHsin-Fu Lin
Hsin-Fu Lin
SWSoun-Cheng Wang
Soun-Cheng Wang
HCHao-Min Cheng
Hao-Min Cheng
JSJun Sugawara
Jun Sugawara
Homebased exercise is often advocated to improve physical fitness in the aging population, especially when outdoor activity is not available. Yet we often have a limited understanding of its training effects for clinical uses. Aim: To investigate a short-term exercise training of standing core exercise on femoral blood flow and vascular hemodynamic changes in middle-aged to the older population. Methods: A total of 33 middle-aged to older adults were recruited and randomly assigned into walking (M/F = 6/7, age = 66 ± 3 years), core exercise (M/F = 6/6, age = 66 ± 2 years), and the control group (M/F = 4/5, age = 70 ± 3 years). Carotid and brachial blood pressure, Carotid-femoral Pulse Wave Velocity (PWV) and Brachial-ankle PWV (baPWV), femoral blood flow and compliance, leg hemodynamics, as well as aerobic and muscular fitness (30 s arm curl and sit-to-stand test) were measured pre and post 8 weeks of exercise training (60–70% HRmax, three sessions/week). Results: Core exercise group significantly increased femoral blood flow, but not overall vascular functions; arm muscle endurance and leg power performance were also significantly improved after training. The walking group significantly reduced baPWV, leg resistance, as well as increase femoral blood flow and compliance after training. Compared with the control, the core group elicited a higher femoral blood blow, whereas leg resistance was significantly reduced in the walking group after training. Conclusion: A short-term standing core training appears to augment femoral blood flow and muscular fitness in middle-aged to older adults, yet walking is more effective in improving overall vascular health in this population. • Standing core training improves femoral blood flow in middle-aged to older adults. • The increase of blood velocity appear to associate with the improvement of blood flow. • Walking exercise training is superior to improve overall vascular function.

17 November 2022 in BMC Sports Science, Medicine and Rehabilitation
Verified
Journal Article
Open access
PDF file
HLHsin-Fu Lin
Hsin-Fu Lin
CCChun-Chung Chou
Chun-Chung Chou
HCHsiao-Han Chao
Hsiao-Han Chao
SWSoun-Cheng Wang
Soun-Cheng Wang
CCChen-Huan Chen
Chen-Huan Chen
Background: Core exercise is often adopted as an adjunct in maintaining musculoskeletal health in rehabilitation; we previously showed that standing core rotational exercise improves femoral blood flow after training. This study aimed to investigate the effects of different rotational cadences on circulatory and hemodynamic responses after acute standing core exercise. Methods: Sixteen healthy male adults (22 ± 1 yrs) were randomly assigned to participate in two 30-min standing core exercises of fast (75 rpm, FC) and slow cadence (20 rpm, SC) sessions after completing an acute bout of seated knee extension exercise session (KE) (80% of 1 repetition maximum × 12 repetitions × 3 sets). Impedance cardiography-derived circulatory responses and femoral hemodynamics by ultrasound imaging were measured pre- and 30, and 60 min post-exercise. Results: KE acutely increased post-exercise cardiac output at 30 min (p = 0.008) and heart rate at 30 min (p = 0.04) and 60 min (p = 0.01), yet brachial blood pressure did not change. Systemic vascular resistance was significantly lower after FC and KE at 30 min (p = 0.008) and 60 (p = 0.04) min, respectively, compared with the baseline. In addition, KE acutely decreased post-exercise arterial stiffness (p = 0.05) at 30 min, increased femoral conductance (p = 0.03, p < 0.001), and blood flow (p = 0.009, p < 0.001) at 30 and 60 min. No significant changes were observed in absolute femoral blood flow after FC and SC, except that FC significantly increased relative femoral blood flow (p = 0.007) and conductance (p = 0.005). Post-exercise femoral diameter significantly increased in KE at 30 (p = 0.03) and 60 min (p = 0.01), but not in core exercise. Conclusion: Our results suggest that standing core exercise elicits circulatory and hemodynamic changes only when the rotational cadence is set at a faster cadence, which provides preliminary scientific evidence for its use in exercise programs.