Takuya Hashimoto

Dr. Takuya Hashimoto

Tokyo University of Science
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2020 in IEEE Access
Verified
Journal Article
Open access
MIMiyu Ide
Miyu Ide
THTakuya Hashimoto
Takuya Hashimoto
KMKenta Matsumoto
Kenta Matsumoto
HKHiroshi Kobayashi
Hiroshi Kobayashi
In order to reduce the burden on the lower back, we have been developing a compact and lightweight “Muscle Suit” that uses McKibben artificial muscles, a type of soft pneumatic actuator. The Muscle Suit for lower back assist has been commercialized and sold over 13,000 units so far; the evaluation of the assist effect is a key point for further development and marketing of the Muscle Suit. In this study, we focus on the assistive effects of two Muscle Suit models: the standard model and the standalone model. The former generates assistive force actively using the actuator, but the latter equips a mechanism generating assistive force passively without the actuator. In the experiments, we first conducted surface electromyogram (sEMG) measurement to examine muscle usage in lifting motion of a heavy weight with or without the Muscle Suit assists. Besides, we estimated the assist force of the Muscle Suit from the perspective of muscle usage ratio. As the result, the evaluation of the overall muscle usage of all measured muscles revealed that the both models of the Muscle Suit reduced muscle usage. We then examined whether the dynamic length of body sways (DLNG) could be used as an indicator of fatigue progressed with performing the lifting motion repeatedly under assist or non-assist conditions. The experimental results confirmed that the reduction of physical fatigue by the Muscle Suit suppressed the change of DLNG value.

14 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ATAkito Tohma
Akito Tohma
MNMaho Nishikawa
Maho Nishikawa
THTakuya Hashimoto
Takuya Hashimoto
YYYoichi Yamazaki
Yoichi Yamazaki
GSGuanghao Sun
Guanghao Sun
Camera-based remote photoplethysmography (rPPG) is a low-cost and casual non-contact heart rate measurement method suitable for telemedicine. Several factors affect the accuracy of measuring the heart rate and heart rate variability (HRV) using rPPG despite HRV being an important indicator for healthcare monitoring. This study aimed to investigate the appropriate setup for precise HRV measurements using rPPG while considering the effects of possible factors including illumination, direction of the light, frame rate of the camera, and body motion. In the lighting conditions experiment, the smallest mean absolute R–R interval (RRI) error was obtained when light greater than 500 lux was cast from the front (among the following conditions—illuminance: 100, 300, 500, and 700 lux; directions: front, top, and front and top). In addition, the RRI and HRV were measured with sufficient accuracy at frame rates above 30 fps. The accuracy of the HRV measurement was greatly reduced when the body motion was not constrained; thus, it is necessary to limit the body motion, especially the head motion, in an actual telemedicine situation. The results of this study can act as guidelines for setting up the shooting environment and camera settings for rPPG use in telemedicine.

1 January 2012 in TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
Verified
Journal Article
Open access
SSS. Sato
S. Sato
JHJiaou He
Jiaou He
HKHiroyuki Kobayashi
Hiroyuki Kobayashi
YMYoshiki Muramatsu
Yoshiki Muramatsu
THTakuya Hashimoto
Takuya Hashimoto

9 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
THTakuya Hashimoto
Takuya Hashimoto
MUMariko Urabe
Mariko Urabe
CFChee Sheng Foo
Chee Sheng Foo
AMAtsuko Murakoshi
Atsuko Murakoshi
TKTakahiro Kikuchi
Takahiro Kikuchi
TKTakuji Koike
Takuji Koike
A detailed understanding of muscle activity in human swallowing would provide insights into the complex neuromuscular coordination underlying swallowing. The purpose of this study was to introduce musculoskeletal analysis to investigate muscle activities involved in swallowing as there are limitations on studying comprehensive muscle activation patterns by conventional methods such as electromyography (EMG) measurement. A musculoskeletal model of swallowing was newly developed based on the skeletal model made from CT data of a healthy volunteer. Individual muscle forces were predicted in pharyngeal swallowing by inverse dynamics’ computations with static optimization, in which the typical trajectories of the hyoid bone and thyroid cartilage analyzed from videofluoroscopic (VF) data of the volunteer were used. The results identified the contribution of individual muscles in pharyngeal swallowing in relation to the movements of the hyoid bone and thyroid cartilage. The predicted sequence of muscle activity showed a qualitative agreement with salient features in previous studies with fine wire EMG measurements. This method, if validated further by imaging and EMG studies, enables studying a broader range of neuromuscular coordination in swallowing. The proposed method offers an avenue to understanding the physiological mechanisms of swallowing and could become useful to evaluate rehabilitation effects on dysphagia.

9 January 2024 in IEEE Access
Verified
Journal Article
Open access
HTHirotaka Tomi
Hirotaka Tomi
TATaichi Araya
Taichi Araya
KKKeisuke Kitano
Keisuke Kitano
KMKenta Matsumoto
Kenta Matsumoto
HKHiroshi Kobayashi
Hiroshi Kobayashi
THTakuya Hashimoto
Takuya Hashimoto
Underwater robots that imitate aquatic life, such as fish-like robots, have attracted attention for oceanographic studies from the viewpoint of morphological affinity for marine life. The existing studies concerning fish-like robots have primarily focused on the swimming mechanism and locomotive performance, and few studies have been conducted on techniques for self-position estimation and obstacle avoidance despite their indispensability in the autonomous navigation of fish-like robots. Therefore, this study aimed to explore a self-positioning estimation method for robotic fish in an environment where global positioning system (GPS) and pre-defined landmarks are not available. To this end, we first developed a fish-like robot that has a laterally flattened shape, which can mimic the swimming pattern of a fish moving forward by waving a tail fin. Next, we realized the function of simple obstacle avoidance using optical distance sensors for autonomous swimming from a practical perspective. Subsequently, we implemented a real-time swimming-path estimation using the posture derived from the inertial measurement unit (IMU) outputs and the swimming speed measured in advance. Furthermore, a swimming path correction method using a particle filter based on a pre-constructed magnetic map was investigated as an alternative to the GPS correction method. Experiments confirmed the accuracy of the swimming path estimation using the proposed method under various conditions, including obstacle avoidance.

20 December 2023 in Journal of Robotics and Mechatronics
Verified
Journal Article
Open access
HSHisaki Sato
Hisaki Sato
HKHiroshi Kobayashi
Hiroshi Kobayashi
KMKenta Matsumoto
Kenta Matsumoto
THTakuya Hashimoto
Takuya Hashimoto
YMYukihiro Michiwaki
Yukihiro Michiwaki
Title: Development of Human-Size Swallowing Robot | Keywords: swallowing robot, robot simulator | Author: Hisaki Sato, Hiroshi Kobayashi, Kenta Matsumoto, Takuya Hashimoto, and Yukihiro Michiwaki