Andres A. Valdez Fernandez

Dr. Andres A. Valdez Fernandez

School of Sciences, Autonomous University of San Luis Potosí, San Luis Potosí City, Mexico
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2007 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
G-Gerardo Escobar -Valderrama
Gerardo Escobar -Valderrama
Andres A. Valdez FernandezAndres A. Valdez Fernandez
Andres A. Valdez Fernandez
JLJ. Leyva-Ramos
J. Leyva-Ramos
PMP. Mattavelli
P. Mattavelli
This paper discusses a repetitive-based controller for an uninterruptible power supply (UPS) inverter. It is shown that a bank of resonant filters, used as a refinement term for harmonic compensation in earlier works, is equivalent to a repetitive scheme with a particular structure. The latter is implemented using a simple feedback array with a delay line, thus making the implementation relatively easy. More precisely, the repetitive scheme takes a negative feedback structure plus a feedforward path whenever the odd harmonics are considered for compensation only. The repetitive scheme, equivalent to the bank of resonant filters, acts as a refinement term to reject the harmonic distortion caused by the unbalanced and distorted load current, and thus, allowing the UPS inverter to deliver an almost pure sinusoidal balanced voltage. Experimental results in a 1.5 KVA three-phase inverter are included to show the performance of the proposed controller

12 March 2007 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
G-Gerardo Escobar -Valderrama
Gerardo Escobar -Valderrama
PMP. Mattavelli
P. Mattavelli
ASA. M. Stankovic
A. M. Stankovic
Andres A. Valdez FernandezAndres A. Valdez Fernandez
Andres A. Valdez Fernandez
JLJesus Leyva-Ramos
Jesus Leyva-Ramos
This paper investigates the control of an uninterruptible power supply (UPS) using a combined measurement of capacitor and load currents in the same current sensor arrangement. The purpose of this combined measurement is, on one hand, to reach a similar performance as that obtained in the inductor current controller with load current feedforward and, on the other hand, to easily obtain an estimate of the inductor current for overcurrent protection capability. Based on this combined current measurement, a voltage controller based on resonant harmonic filters is investigated in order to compensate for unbalance and harmonic distortion on the load. Adaptation is included to cope with uncertainties in the system parameters. It is shown that after transformations the proposed controller gets a simple and practical form that includes a bank of resonant filters, which is in agreement with the internal model principle and corresponds to similar approaches proposed recently. The controller is based on a frequency-domain description of the periodic disturbances, which include both symmetric components, namely, the negative and positive sequence. Experimental results on the output stage of a three-phase three-wire UPS are presented to assess the performance of the proposed algorithm

14 June 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
G-Gerardo Escobar -Valderrama
Gerardo Escobar -Valderrama
MMMisael F. Martinez-Montejano
Misael F. Martinez-Montejano
Andres A. Valdez FernandezAndres A. Valdez Fernandez
Andres A. Valdez Fernandez
PANFILO RAYMUNDO MARTINEZ RODRIGUEZPANFILO RAYMUNDO MARTINEZ RODRIGUEZ
PANFILO RAYMUNDO MARTINEZ RODRIGUEZ
MHMichael Hernandez-Gomez
Michael Hernandez-Gomez
This paper presents a grid synchronization scheme aimed to provide an estimation of the angular frequency and both the positive and negative sequences of the fundamental component of an unbalanced three-phase signal. These sequences are provided in fixed-reference-frame coordinates, and thus, the proposed algorithm is referred to as fixed-reference-frame phase-locked loop (PLL) (FRF-PLL). In fact, the FRF-PLL does not require transformation of variables into the synchronous frame coordinates as in most PLL schemes. Therefore, the proposed scheme is not based on the phase angle detection. Instead, the angular frequency is detected and used for synchronization purposes. The design of the FRF-PLL is based on a complete description of the source voltage involving both positive and negative sequences in stationary coordinates and considering the angular frequency as an uncertain parameter. Therefore, the FRF-PLL is intended to perform properly under severe unbalanced conditions and to be robust against angular frequency variations, sags, and swells in the three-phase utility voltage signal. Due to the selective nature of the scheme, it shows certain capability to alleviate the effect of harmonic distortion that is present in the utility voltage signal.

12 September 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Andres A. Valdez FernandezAndres A. Valdez Fernandez
Andres A. Valdez Fernandez
PANFILO RAYMUNDO MARTINEZ RODRIGUEZPANFILO RAYMUNDO MARTINEZ RODRIGUEZ
PANFILO RAYMUNDO MARTINEZ RODRIGUEZ
G-Gerardo Escobar -Valderrama
Gerardo Escobar -Valderrama
CLCesar A. Limones-Pozos
Cesar A. Limones-Pozos
JSJose M. Sosa
Jose M. Sosa
This paper presents the modeling and control processes of the single-phase cascade H-bridge multilevel converter used as a shunt active filter. Based on the obtained model, a controller is proposed to compensate for harmonic distortion and reactive power caused by a nonlinear load. These issues are solved by guaranteeing tracking of the line current toward an appropriately defined current reference. In the proposed approach, the current reference has been selected to be a signal proportional to either the line voltage or to its fundamental component; however, the proposed method can also be extended to other reference definitions. The proposed controller also includes voltage loops to guarantee regulation and balance of the involved capacitor voltages toward constant references. Experimental results on a 2-kVA prototype are presented to assess the performance of the proposed controller.

17 September 2019 in IET Power Electronics
Verified
Journal Article
Closed access
JSJOSE ANGEL PECINA SANCHEZ
JOSE ANGEL PECINA SANCHEZ
Daniel Ulises Campos-DelgadoDaniel Ulises Campos-Delgado
Daniel Ulises Campos-Delgado
DEDiego R. Espinoza‐Trejo
Diego R. Espinoza‐Trejo
Andres A. Valdez FernandezAndres A. Valdez Fernandez
Andres A. Valdez Fernandez
CACristian H. De Angelo
Cristian H. De Angelo
This study presents a fault detection and isolation (FDI) method for open‐circuit faults (OCFs) in the switching devices of a grid‐connected neutral‐point‐clamped (NPC) inverter for photovoltaic (PV) applications. The proposed methodology addresses the fault diagnosis problem by a combined model‐based and data processing perspective to study single and simultaneous faults in the NPC inverter. For the model‐based scheme, a bank of sliding‐mode proportional–integral observers is suggested to estimate the fault profiles under an additive model. Thus, from the estimated fault profiles, and by performing a directional residual evaluation in a fixed reference frame, single and simultaneous fault scenarios can be isolated in the NPC inverter. However, for some fault classes, there is some ambiguity by just the model‐based approach that is overcome by employing the average line currents to construct extra fault signatures. The proposed FDI scheme only requires the measurements of line currents and grid voltages in the diagnosis media and can isolate single OCFs and simultaneous OCFs in the order or lower than a fundamental period of the grid frequency. Our new FDI methodology is validated through experimental data from a practical PV system in a closed‐loop grid‐connected NPC inverter under single and simultaneous OCF conditions.

25 April 2005 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
G-Gerardo Escobar -Valderrama
Gerardo Escobar -Valderrama
JLJ. Leyva-Ramos
J. Leyva-Ramos
PANFILO RAYMUNDO MARTINEZ RODRIGUEZPANFILO RAYMUNDO MARTINEZ RODRIGUEZ
PANFILO RAYMUNDO MARTINEZ RODRIGUEZ
Andres A. Valdez FernandezAndres A. Valdez Fernandez
Andres A. Valdez Fernandez
A novel repetitive based-control strategy is proposed for the pulsewidth modulated (PWM) boost converter to compensate the output voltage ripple due to the harmonic distortion present in the input voltage. Repetitive control has shown to be a useful tool for tracking of periodic reference signals and for compensation of periodic disturbances, in other words, for harmonic compensation. The structure of the proposed controller is preserved as close as possible to the conventional one, which includes outer and inner control loops. Thus, in the proposed controller, the repetitive strategy appears as a refinement term added to the inner control loop. We show that the repetitive strategy can be built using a single analog delay integrated circuit, thus, simplifying enormously the implementation. The repetitive strategy is able to cancel almost every remaining harmonic distortion component while maintaining an acceptable dynamical performance and without inclusion of additional hardware in the power stage. Experimental results on a boost converter board, using a poorly regulated voltage source, are presented to assess the performance of our approach.