Among most challenging open issues in prosthetic research is the development of a robust bidirectional interface between a prosthesis and its user. Commercially available prosthetic systems are mechanically advanced, but they do not provide somatosensory feedback. Here, we present a novel non-invasive interface for multichannel electrotactile feedback, comprising a matrix of 24 pads, and we investigate the ability of able-bodied human subjects to localize the electrotactile stimulus delivered through the matrix. For this purpose, we tested conventional stimulation (same frequency for all pads) and a novel dual-parameter modulation scheme (interleaved frequency and intensity) designed to facilitate the spatial localization over the electrode. Electrotactile stimulation was also compared to mechanical stimulation of the same locations on the skin. Experimental results on eight able-bodied subjects demonstrated that the proposed interleaved coding substantially improved the spatial localization compared to same-frequency stimulation. The results also showed that same-frequency stimulation was equivalent to mechanical stimulation, whereas the performance with dual-parameter modulation was significantly better. These are encouraging outcomes for the application of a multichannel interface for the restoration of feedback in prosthetics. The high-resolution augmented interfaces might be used to explore novel scenarios for effective communication with the prosthesis user enabled by maximizing information transmission.
This paper proposes a validation method of the fabrication technology of a screen-printed electronic skin based on polyvinylidene fluoride-trifluoroethylene P(VDF-TrFE) piezoelectric polymer sensors. This required researchers to insure, through non-direct sensor characterization, that printed sensors were working as expected. For that, we adapted an existing model to non-destructively extract sensor behavior in pure compression (i.e., the d33 piezocoefficient) by indentation tests over the skin surface. Different skin patches, designed to sensorize a glove and a prosthetic hand (11 skin patches, 104 sensors), have been tested. Reproducibility of the sensor response and its dependence upon sensor position on the fabrication substrate were examined, highlighting the drawbacks of employing large A3-sized substrates. The average value of d33 for all sensors was measured at incremental preloads (1–3 N). A systematic decrease has been checked for patches located at positions not affected by substrate shrinkage. In turn, sensor reproducibility and d33 adherence to literature values validated the e-skin fabrication technology. To extend the predictable behavior to all skin patches and thus increase the number of working sensors, the size of the fabrication substrate is to be decreased in future skin fabrication. The tests also demonstrated the efficiency of the proposed method to characterize embedded sensors which are no more accessible for direct validation.
Modern prostheses aim at restoring the functional and aesthetic characteristics of the lost limb. To foster prosthesis embodiment and functionality, it is necessary to re-establish both volitional control and sensory feedback. Contemporary feedback interfaces presented in research use few sensors and stimulation units to feedback at most two discrete feedback variables (e.g., grasping force and aperture), whereas the human sense of touch relies on a distributed network of mechanoreceptors providing high-fidelity spatial information. To provide this type of feedback in prosthetics, it is necessary to sense tactile information from artificial skin placed on the prosthesis and transmit tactile feedback above the amputation in order to map the interaction between the prosthesis and the environment. This paper will provide a perspective on the use of distributed sensing and electrical stimulation systems for the restoration of the sense of touch in prosthetics.
The lack of tactile sensation in current upper limb prostheses is the key limitation to enable more intuitive use of the prosthesis and restore the functionality of the natural limb. Electronic skin in the form of tactile sensing arrays can be integrated onto the upper limb prosthetic device to record information about touch, given back to the amputee as a sensory feedback. This contribution focusses on the development of tactile sensing arrays based on PVDF-TrFE piezoelectric polymers. Both piezoelectric polymer sensors and metal contacts have been screen-printed on a transparent plastic foil. The geometric layout and size of the 4×4 array is suitable for prosthesis fingertips. Preliminary experimental validation of the skin patches is reported in this paper.
24 August 2023 in IEEE Transactions on Biomedical Engineering
Snoring is a prominent characteristic of sleep-disordered breathing, and its detection is critical for determining the severity of the upper airway obstruction and improving daily quality of life. Home snoring analysis is a highly invasive method, but it becomes challenging when a sleeping partner also snores, leading to distorted evaluations in such environments. In this paper, we tackle the problem of complex snore signal separation of multiple snorers. This article introduces two audio-based methods that efficiently extract an individual's snoring signal, allowing for the analysis of sleep-breathing disorders in a normal sleeping environment without isolating individuals. In the first method, Principal Component Analysis (PCA) identifies the source components from the finite number of modes generated by the decomposition of the snoring mixture using Multivariate Variational Mode Decomposition (MVMD). The second method applies Blind Source Separation (BSS) based on Non-Negative Matrix Factorization (NMF) to separate the single-channel snoring mixture. Furthermore, the decomposed signals are tuned using the iterative enhancement algorithm to adequately match the source snoring signals. These methods were evaluated by simulating various real-time snoring recordings of 7 subjects (2 men, 2 women, and 3 children). The correlation coefficient between the source and its separated signal was computed to assess the separation results, exhibiting good performance of the methods used. The enhancement approach also demonstrated its efficiency by increasing the correlation over to 80% in both methods. The experimental results show that the proposed algorithms are effective and practical for separating mixed snoring signals.
Reconstructing the sense of touch in prosthetics is a long-standing research challenge. To this aim, the prosthesis can be supplied with sensory arrays to measure the tactile interaction with the environment. In addition, a reliable feedback system is required to code and transmit the measured somatosensory information to the residual limb. This paper presents a multichannel electrotactile stimulation interface. Two coding schemes (mixed and uniform coding) were tested to assess the ability of the subject to localize the stimulation (identify the active pad). The outcome measures were position recognition and frequency discrimination. Our preliminary results show high accuracies in discriminating different frequency levels, i.e., 80% for low-level frequencies and 87% for high-level frequencies. In addition, the mixed coding has substantially improved the spatial localization. These are important insights regarding the development of multichannel sensing and stimulation systems for feedback in prosthetics.