This paper proposes a fault diagnosis and tolerant control methods for an open-switch fault caused in a three-phase three-level neutral-point-clamped (NPC) pulse-width modulation (PWM) active rectifier. The open-switch fault in the three-level NPC active rectifier causes a distortion in the input phase current and a ripple in the DC-link capacitor voltage. Therefore, proper fault diagnosis and tolerant control methods are required to prevent additional failures and performance degradation in the rectifier system. This paper conducted a detailed analysis of the effect of the single open-switch fault on the NPC PWM active rectifier and proposed a fault diagnosis method utilizing the DC link voltage and the phase angle of the input grid voltage. Furthermore, this paper proposes a fault-tolerant control method to reduce the effect of the open-switch fault by compensating a distorted reference voltage. The effectiveness of the proposed fault diagnosis and tolerant control methods are verified through experimental results.
This paper proposes a pulse-width-modulation (PWM) control strategy for the efficient operation of the three-phase three-level neutral-point-clamped (NPC) inverters with a bootstrap gate drive circuit. The bootstrap circuit used in the three-level NPC inverter has advantages in terms of the cost reduction and the compact circuit design. However, the bootstrap circuit has a drawback due to the low gate-emitter voltage during the low-frequency and variable load condition of the inverter system. This problem leads to lower efficiency and reliability of the inverter. Therefore, this paper analyzes the causes of the voltage decrease in bootstrap capacitors and proposed PWM control strategy to increase the voltage level of bootstrap capacitors for the efficient operation of the inverter. The proposed PWM control strategy provides efficient and stable operation of the inverter system by selecting the unipolar, dipolar or partial-dipolar modulation methods according to the fundamental output frequency and load current of the inverter system. Furthermore, this paper proposes a design method of the size of bootstrap capacitors for the optimal circuit design. The effectiveness of the proposed PWM control strategy is verified using the experimental results.
This paper proposes the full simulation model for the electrical analysis of all-electric ship (AES) based on a medium voltage DC power system. The AES has become popular both in the commercial and the military areas due to a low emission, a high fuel consumption efficiency, and a wide applicability. In spite of many advantages, it is complex and difficult to construct the whole system with many mechanical and electrical components onboard. Full electrical analysis is essentially required to simplify the design of the AES, a control and optimization of a ship electric system. The proposed full simulation model of the AES includes the mechanical and the electrical elements by using the MATLAB/Simulink. The mechanical elements are comprised of a steam turbine and a hydrodynamic model of a ship which is adopted by an average value model that is based on the characteristic equation of the mechanical system. The electrical elements are developed by full detailed models which consist of generators, a propulsion motor, a battery, and a power electronics system. In order to design the distribution of the ship, the presented simulation model combined the mechanical and the electrical systems. The consistency of the developed individual models and the integrated AES was verified through the results of the presence or absence of the energy storage system for the speed acceleration and deceleration, loss of prime mover, and full propulsion load rejection.
4 March 2025 in International Journal of Electrical Power & Energy Systems