Yung-Deug Son

Prof. Yung-Deug Son

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
HHHong-Jun Heo
Hong-Jun Heo
YSYung-Deug Son
Yung-Deug Son
JKJang-Mok Kim
Jang-Mok Kim
Position control is usually achieved using a position controller and a profile generator. The profile generator produces a desired position trajectory from a position reference and predefined profiles. The position controller forces the actual position to trace the generated position trajectory. A time-based profile generator is the most famous profile generator due to its capability of generating various profiles. However, time base difference in analysis and implementation causes a steady-state error. In order to remove the steady-state error, this paper proposes a novel profile generator for a trapezoidal velocity profile generation. The proposed generator is based on a cascaded P-PI position controller which is designed to trace the position reference. A dynamic range limiter is adopted to provide the acceleration and velocity restrictions which are basic functions for generating the trapezoidal profile. In spite of these restrictions, it cannot make a desired velocity profile only using the limiter because deceleration point is inaccurate. To adjust the deceleration point, a feedback compensator is designed which requires the velocity of the deceleration point. The velocity of the deceleration point is estimated from the initial position error. The compensator moves the deceleration point to the appropriate point which can generate the desired velocity profile. The proposed profile generator can remove the steady-state error, and the position response can be easily adjusted to be either overdamped or underdamped by selecting the two gains appropriately. Several experimental results are presented to verify the usefulness of the proposed generator.

28 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
JJJunhyung Jung
Junhyung Jung
HKHyun-Keun Ku
Hyun-Keun Ku
YSYung-Deug Son
Yung-Deug Son
JKJang-Mok Kim
Jang-Mok Kim
This paper proposes a fault diagnosis and tolerant control methods for an open-switch fault caused in a three-phase three-level neutral-point-clamped (NPC) pulse-width modulation (PWM) active rectifier. The open-switch fault in the three-level NPC active rectifier causes a distortion in the input phase current and a ripple in the DC-link capacitor voltage. Therefore, proper fault diagnosis and tolerant control methods are required to prevent additional failures and performance degradation in the rectifier system. This paper conducted a detailed analysis of the effect of the single open-switch fault on the NPC PWM active rectifier and proposed a fault diagnosis method utilizing the DC link voltage and the phase angle of the input grid voltage. Furthermore, this paper proposes a fault-tolerant control method to reduce the effect of the open-switch fault by compensating a distorted reference voltage. The effectiveness of the proposed fault diagnosis and tolerant control methods are verified through experimental results.

3 October 2021 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
YSYung-Deug Son
Yung-Deug Son
SBSang-Do Bin
Sang-Do Bin
GJGang-Gyoo Jin
Gang-Gyoo Jin

3 July 2019 in Studies in Informatics and Control
Verified
Journal Article
Closed access
GJGang-Gyoo Jin
Gang-Gyoo Jin
YSYung-Deug Son
Yung-Deug Son

1 October 2018 in Energies
Verified
Journal Article
Open access
PDF file
YSYung-Deug Son
Yung-Deug Son
JKJang-Mok Kim
Jang-Mok Kim
This paper presents three phase current reconstruction methods for a three-level neutral point clamped inverter (NPCI) by measuring the voltage of a shunt resistor placed in the neutral point of the inverter. In order to accurately acquire the phase currents from the shunt resister, the dwell time of the active voltage vectors need to exceed the minimum time. On the other hand, if the time of active voltage is shorter than the minimum time, the current measurement becomes impossible. In this paper, unmeasurable regions for current are classified into three areas. Area 1 is a region in which both phase currents can be measure. Therefore, it is not necessary to restore the current. In Area 2, only one phase current can be measured. Thus, an estimation or restoration method is needed to measure another phase current. In this paper, the current estimation method using an electrical model of the motor is proposed. Area 3 is the region in which both phase currents can not be measured. In this case, it is necessary to move the voltage vector to the current measurable area by injecting the voltage. In this paper, Area 3 is divided into 36 sectors to inject optimal voltage. The proposed methods have the advantages of high current measurement accuracy and low THD (total harmonic distortion). The effectiveness of the proposed methods are verified through experimental results.

13 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
CPChangHwan Park
ChangHwan Park
DKDong-Youn Kim
Dong-Youn Kim
HYHan-Beom Yeom
Han-Beom Yeom
YSYung-Deug Son
Yung-Deug Son
JKJang-Mok Kim
Jang-Mok Kim
To reduce the cost of the inverter system in home appliances, a method using a shunt resistor at the DC-link can be substituted for a method using two current sensors at the inverter output. However, the minimum time of the active vector is required to sample the accurate current using a 1-shunt resistor. Therefore, many studies have been conducted investigating current reconstruction methods in the unmeasurable region of the current. The conventional methods using voltage injection have some problems such as high THD (Total Harmonic Distortion) and acoustic noise, because the PWM pattern is shifted. In addition, the current reconstruction is inaccurate in a low modulation region. In this paper, the cause of the noise in conventional methods is analyzed and a simple current reconstruction method based on an average current estimation and a current reference is utilized for reducing acoustic noise. In an immeasurable area, especially a low modulation region, an intermittent PWM shift method is proposed to enhance the accuracy of the reconstructed current. Therefore, a control strategy that combines all of the mentioned methods is implemented for the entire operating range. The effectiveness of the proposed methods is verified through the experimental results and the results of sound measurement in an anechoic chamber are included to compare with the acoustic noise.