The integration of electronically active oxide transistors onto silicon circuits represents an innovative approach to improving the performance of devices. In this paper, we present high performance oxide transistor for use as gate drive circuitry integrated on top of a power electronic device, providing a novel power system. Specifically, as a core device component in gate driver, oxide transistor exhibits remarkable performance such as, high mobility (23~47cm 2 /Vs) and high breakdown voltage (BV) of 60~340V despite low process temperatures (<;300°C). In addition, we demonstrate the dynamic behavior of the inverter and the latch produced by oxide transistor and thus a complete and functioning gate drive circuitry can be implemented on top of power management integrated circuit (PMIC) as depicted in the report.
Recently, the application of bio-signals in the fields of health management, human–computer interaction (HCI), and user authentication has increased. This is because of the development of artificial intelligence technology, which can analyze bio-signals in numerous fields. In the case of the analysis of bio-signals, the results tend to vary depending on the analyst, owing to a large amount of noise. However, when a neural network is used, feature extraction is possible, enabling a more accurate analysis. However, if the bio-signal time series is analyzed as is, the total neural network increases in size. In this study, to accomplish a light-weight neural network, a maximal overlap discrete wavelet transform (MODWT) and a smoothing technique are used for better feature extraction. Moreover, the learning efficiency is increased using an augmentation technique. In designing the neural network, a one-dimensional convolution layer is used to ensure that the neural network is simple and light-weight. Consequently, the light-weight attribute can be achieved, and neural networks can be implemented in edge devices such as the field programmable gate array (FPGA), yielding low power consumption, high security, fast response times, and high user convenience for wearable applications. The electromyogram (EMG) signal represents a typical bio-signal in this study.
Upon light exposure, an indium-zinc-oxide (IZO) thin-film transistor (TFT) presents higher photoconductivity by several orders of magnitude at the negative gate bias region. Among various device geometrical factors, scaling down the channel length of the photo-transistor results in an anomalous increase in photoconductivity. To probe the origin of this high photoconductivity in short-channel device, we measured transient current, current–voltage, and capacitance–voltage characteristics of IZO–TFTs with various channel lengths and widths before and after illumination. Under the illumination, the equilibrium potential region which lies far from front interface exists only in short-channel devices, forming the un-depleted conducting back channel. This region plays an important role in carrier transport under the illumination, leading to high photoconductivity in short-channel devices. Photon exposure coupled with gate-modulated band bending for short-channel devices leads to the accumulation of Vo++ at the front channel and screening negative gate bias, thereby generating high current flow in the un-depleted back-channel region.
Emotion recognition, which includes stress analysis, is a critical research topic. In particular, emotion recognition using wearable applications that offer rapid feedback can significantly assist in emotion regulation. A key dataset for this purpose is the wearable stress and affect detection (WESAD) dataset, which is well-suited for wearable environments. This study aims to evaluate the accuracy and processing time of the proposed neural network using the WESAD dataset. However, data collected in wearable environments often have limitations in terms of their accuracy and channel count, making classification challenging. To address this issue, this study utilizes only wrist-measured blood volume pulse (BVP) data measured by photo-plethysmography (PPG) and electro-dermal activity (EDA) data, classifying them through a late fusion-based multimodal method. For accurate classification, the BVP data are preprocessed using the empirical mode decomposition (EMD) method, and a Siamese model is employed for learning on small datasets, with an additional structure of dense layers for detailed classification. The Siamese network generates a similarity score, which is then fed into a dense layer to classify multiple classes. Meta-classes are used to compute pairwise similarities, ultimately classifying the data into one of four emotional states: neutral, stress, amusement, and meditation. The proposed multitasking model simultaneously trains the Siamese network and multi-classifier, achieving an accuracy of 99.8% in classifying four emotion states in the WESAD dataset. Moreover, the model is designed to operate with minimal hardware resources, making it easy to implement using hardware accelerators. This study demonstrates the applicability of neural network-based wearable systems in the field of emotion recognition.
Transformer models are widely used in natural language processing (NLP) and time-series data analysis. Applications of these models include prediction systems and hand gesture recognition using electromyogram (EMG) signals. However, in the case of time-series analysis, the models perform similarly to traditional networks, contrary to expectations. This study aimed to compare the performance of the transformer model and its various modified versions in terms of accuracy through a user authentication system using EMG signals, which exhibit significant variability and pose challenges in feature extraction. A Siamese network was employed to distinguish subtle differences in the EMG signals between users, using Euclidean distance. Data from 100 individuals were used to create a challenging scenario while ensuring accuracy. Three scenarios were considered: data preprocessing, integration with existing models, and the modification of the internal structure of the transformer model. The method that achieved the highest accuracy was the bidirectional long short-term memory (BiLSTM)–transformer approach. Based on this, a network was further constructed and optimized, resulting in a user authentication accuracy of 99.7% using EMG data from 100 individuals.
User authentication has traditionally been performed using methods such as passwords or fingerprints. However, passwords have security vulnerabilities, and fingerprints may hinder user convenience. To address these issues, a novel user authentication method based on biosignals, specifically electromyogram (EMG) signals, is proposed. Using biosignals like EMG offers several advantages, including the ability to acquire data without user awareness, independence from the user’s environment, rapid acquisition, and enhanced security. However, one challenge with using EMG signals for authentication has been their relatively low accuracy. In this paper, a neural network is implemented using a small number of parameters (fewer than 7000) to produce a wearable device using biosignals, and user authentication accuracy is secured using the maximal overlap discrete wavelet transform (MODWT) method and the Siamese network. The MODWT method is highly effective for the time and frequency analysis of time series data, and the Siamese network is a representative method for few-shot learning. The proposed neural network is verified using Chosun University’s user authentication dataset, encompassing data from 100 individuals. Finally, this proposed network is implemented on an edge device such as field-programmable gate arrays (FPGAs) so that it can be applied to a wearable user authentication system. By implementing the Siamese network in FPGA-based edge devices, it was possible to secure user authentication performance at 94% accuracy and an authentication speed within 1.5 ms. In the case of accuracy, it is expected to be further improved by using the multimodal technique of biosignals. Also, the proposed system can be easily fabricated for digital integrated chips (ICs).