Ibram Y. Fawzy

Dr. Ibram Y. Fawzy


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Advanced Engineering Trends
Verified
Journal Article
Closed access
PDF file
Ibram Y. FawzyIbram Y. Fawzy
Ibram Y. Fawzy
YMY.S. Mohamad
Y.S. Mohamad
ESE. .G. Shehata)
E. .G. Shehata)
MSMontaser Abd El Sattar
Montaser Abd El Sattar
A photovoltaic system (PV) connected to the utility grid through three-phase voltage source inverter (VSI) has been controlled in this paper for achieving maximum power point tracking (MPPT). In this paper, a modified perturb and observe (P&O) technique has been proposed for achieving MPPT of PV system using DC-DC boost converter. The proposed algorithm is used to obtain better capture of energy with minimum steady state oscillations. In this technique, the duty cycle is determined using a variable step-size to achieve MPPT accurately. A digital simulation using Matlab/Simulink package is carried out to demonstrate the advantage of the proposed system performance compared to the conventional technique under varying irradiation and temperature levels. The obtained results investigate that the modified algorithm can track the maximum power point (MPP) accurately besides, it extracts the additional power during the variation in weather conditions as compared to the conventional P&O algorithm.

27 February 2024 in Journal of Robotics and Control (JRC)
Verified
Journal Article
Open access
PDF file
Ibram Y. FawzyIbram Y. Fawzy
Ibram Y. Fawzy
Mahmoud A.MossaMahmoud A.Mossa
Mahmoud A.Mossa
AEAhmed M. Elsawy
Ahmed M. Elsawy
ISIswanto Suwarno
Iswanto Suwarno
AHMED DIABAHMED DIAB
AHMED DIAB
This paper purposes to demonstrate the effectiveness of fuzzy logic controller (FLC) over proportional integral (PI) controller for reducing the fault current and maintaining the voltage profile at different faults conditions using Static Synchronous Compensator (STATCOM) which is considered an effective FACTS (Flexible Alternating Current Transmission System) device. The study evaluates the performance of a power system equipped with STATCOM which is connected in shunt with bus B1 under various faults conditions, including single-phase and three-phase faults. The performance of the STATCOM is evaluated by using two different controllers: PI controllers and FLCs. A comparative analysis is done between the performances of the two different controllers using Matlab/Simulink software package. The results obtained conclude that the presented system gives better performance with STATCOM as compared to not using it under several faults conditions besides, the STATCOM gives better response with FLC as compared to PI controller. It is demonstrated that STATCOM with FLC can reduce the positive sequence fault current at bus B1 ‎to 96.49% of its value without ‎using STATCOM under line to ground fault and 98.17% under three line to ‎ground fault whereas STATCOM with PI controller can reduce it ‎to (99.57, 99.05%), respectively. Also, the bus voltage B1 is improved to 102.19% by using STATCOM with fuzzy controller under line to ground fault and 101.86% under three line to ‎ground fault whereas STATCOM with PI controller can improve it ‎to (100.21, 100.93%), respectively.

25 October 2023 in International Journal of Robotics and Control Systems
Verified
Journal Article
Open access
PDF file
Ibram Y. FawzyIbram Y. Fawzy
Ibram Y. Fawzy
Mahmoud A.MossaMahmoud A.Mossa
Mahmoud A.Mossa
AEAhmed M. Elsawy
Ahmed M. Elsawy
ADAhmed A. Zaki Diab
Ahmed A. Zaki Diab
In this paper, a comparison between Flexible Alternating Current Transmission System (FACTS) devices including Static Synchronous Compensator (STATCOM), Static Synchronous Series Compensator (SSSC) and Unified Power Flow Controller (UPFC) for providing a better adaptation to changing operating conditions and improving the usage of current systems. The power system using FACTS devices is presented under different conditions such as single phase fault and three phase fault. A digital simulation using Matlab/Simulink software package is carried out to demonstrate the better performance including the voltage and the current of the presented system using FACTS that located between buses B1 and B2 under different faults types. The results obtained investigate that the presented system gives better response with FACTS as compared to not using them under abnormal conditions besides, the UPFC gives better performance of power system under several faults as compared to STATCOM or SSSC as It can absorb reactive power in a manner which significantly reduced the fault current. It is demonstrated that UPFC can reduce the peak fault current at bus B1 ‎to 63.85% of its value without ‎using FACTS devices under line to ground fault and 79.18% under three line to ‎ground fault whereas STATCOM and SSSC reduce it ‎to (75.21, 94.35%) and (75.40, 94.68%), respectively.

4 March 2025 in Processes
Verified
Journal Article
Open access
PDF file
AHMED DIABAHMED DIAB
AHMED DIAB
SDSaleh Al Dawsari
Saleh Al Dawsari
Ibram Y. FawzyIbram Y. Fawzy
Ibram Y. Fawzy
AEAhmed M. Elsawy
Ahmed M. Elsawy
AAAyat AboElmagd
Ayat AboElmagd
This paper examines the deployment of a 25 MVA Static Synchronous Compensator (STATCOM) to improve voltage stability in a real 66 kV 525 MVA transmission network in the Middle Egypt Electricity Zone. A MATLAB/Simulink model is developed to assess the performance of the STATCOM in both normal and fault conditions, including single-phase and three-phase faults. The STATCOM regulates the voltage by adjusting it within ±10% of the nominal value and is connected to a shunt with the bus B11. Four control strategies are implemented: a proportional–integral (PI) controller, an adaptive neuro-fuzzy inference system (ANFIS), a fuzzy logic controller (FLC), and an FLC combined with a supercapacitor. FLCs outperform PI controllers in maintaining voltage stability; however, they exhibit limitations regarding their responsiveness to dynamic changes within the network. The findings demonstrate that the STATCOM enhances the voltage and current stability compared to the system without this component. The ANFIS controller demonstrates optimal performance characterized by minimal waveform fluctuations. Under standard conditions, a single STATCOM integrated with an ANFIS elevates the bus voltages to 100.382% (B10) and 101.953% (B11), surpassing the performance of the FLC (100.314% and 101.246%) and the FLC–supercapacitor combination (100.326% and 101.392%). The deployment of two STATCOM units alongside an ANFIS improves the voltage levels to 102.122% (B10) and 102.200% (B11). The findings demonstrate that the AN-FIS-controlled STATCOM enhances system performance under normal operating conditions, voltage source fluctuations, and fault scenarios. The deployment of two STATCOM units, each rated at 25 MVA and controlled by an ANFIS, significantly enhances voltage stability compared to a single unit.

1 April 2025 in Journal of Engineering Advances and Technologies for Sustainable Applications
Verified
Journal Article
Open access
PDF file
AHMED DIABAHMED DIAB
AHMED DIAB
Ibram Y. FawzyIbram Y. Fawzy
Ibram Y. Fawzy
AEAhmed M. Elsawy
Ahmed M. Elsawy
AEAyat G. Abo El-Magd
Ayat G. Abo El-Magd
Renewable energy sources (RES) has gained pivotal importance due to the depletion of fossil fuels, coupled with increasing electricity demand and escalating environmental concerns. The integration of renewables into power systems significantly impacts grid performance. Addressing transient performance issues remains a critical area that requires further investigation. This paper explores the deployment of a Static Synchronous Compensation Device (STATCOM) utilizing a controller based on fuzzy logic (FLC) to tackle voltage stability issues in the IEEE nine-bus investigation, specifically considering the incorporation of Photovoltaic (PV) and Wind energy. The STATCOM based on FLC is considered as a dynamic voltage recovery aimed at sustaining voltage stability, thus preservation of RES through and after occurring disturbances. A virtual simulation is performed utilizing Matlab/Simulink environment with Proportional Integrative (PI) controller and with FLC of the STATCOM under different conditions to prominence the variation which the offered STATCOM presents concerning transient stability. The study aims to illustrate the effectiveness of FLC over PI controller for enhancing the system stability at different locations using STATCOM device. The obtained results inspect that STATCOM contributes better response through FLC under abnormal conditions as compared to PI controller.