A photovoltaic system (PV) connected to the utility grid through three-phase voltage source inverter (VSI) has been controlled in this paper for achieving maximum power point tracking (MPPT). In this paper, a modified perturb and observe (P&O) technique has been proposed for achieving MPPT of PV system using DC-DC boost converter. The proposed algorithm is used to obtain better capture of energy with minimum steady state oscillations. In this technique, the duty cycle is determined using a variable step-size to achieve MPPT accurately. A digital simulation using Matlab/Simulink package is carried out to demonstrate the advantage of the proposed system performance compared to the conventional technique under varying irradiation and temperature levels. The obtained results investigate that the modified algorithm can track the maximum power point (MPP) accurately besides, it extracts the additional power during the variation in weather conditions as compared to the conventional P&O algorithm.
26 December 2018 in International Transactions on Electrical Energy Systems
In this paper, an energy management strategy of direct current (DC) microgrids (MGs) is presented. The proposed MG consists of fuel cells, batteries, and supercapacitors, along with associated DC/DC and DC/AC converters. Coordination between different sources of MG is implemented using a multi‐agent system. Multi‐agent algorithm is implemented using an open source agent building toolkit, Java Agent Development framework (JADE). The energy source components are modeled and implemented using MatLab/Simulink (power system library). The proposed energy management strategy is designed using proportional‐integral (PI) controllers, which is implemented using the JADE. Interface between MatLab/Simulink and multi‐agent system (JADE) is done with the help of MACSimJX. The proposed multi‐agent framework is presented and the interface between the JADE and MatLab/Simulink is described in details. Then, the design and implementation steps of the PI controller using JADE are presented. Simulation work is carried out, and the results show that the proposed multi‐agent‐based controller effectively coordinated with variable loads in MG.
The integration of wind energy systems (WECS) into the power grid through power electronic converters should ensure the high performance of the control system. In spite of several advantages of conventional Finite control set-model predictive controller (FCS-MPC), variable switching frequency and high computational burden are considered its main drawbacks. In this paper, a fast FCS-MPC of a machine side converter (MSC) of direct-driven permanent magnet synchronous generator (PMSG) based wind turbines for wind energy conversion system is proposed. The wind energy conversion system has been realized using a direct driven PMSG and a full-scale back-to-back power converter. The proposed controller is designed to reduce the required calculations in each horizon. In addition, the performance of conventional FCS-MPC is compared with the proposed method, and an improvement in total harmonic distortion spectra and simulation time required even when imposing a lower sampling frequency was found. To overcome the variable switching frequency problem, a modulation algorithm is introduced in the minimization process of modulated FCS-MPC. To keep the proposed system attached to the utility during a fault, a coordinated pitch angle control and low voltage-ride through (LVRT) algorithm is designed and inserted in the vector control of the grid side converter (GSC) to supply reactive power to the grid during fault for ensuring safe operation of the inverter and meeting the grid code requirements. The effectiveness of the proposed controller is illustrated using simulation results under different operating conditions.
Shunt Active Power Filter (APF) is one of most preferred filters for the mitigation of harmonics in power systems. The controller part of shunt APF plays an important role to generate a reference current which compensate/cancel the distorted currents. The APF injects current equal but opposite to the harmonic components, in turn the fundamental components only flows in the point of common coupling (PCC). In this studying, for four controls algorithm are proposed to control the shunt active filter. Instantaneous Active-Reactive Power Theory (PQ), an adaptive phase locked loop (PLL), Instantaneous active and reactive current method (DQ) and Synchronous detection method (SD) are designed to generate the reference current of APF for mitigation of harmonics. The performance of the four methods are analyzed and compared under different operating conditions. The load is assumed to have high nonlinear characteristics. Digital simulations are carried out to demonstrate the performance of the proposed algorithms using matlab/Simulink software package.