ILKNUR DURUKAN

Prof. Dr. ILKNUR DURUKAN

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in Dyes and Pigments
Verified
Journal Article
Closed access
KTKadir Turhan
Kadir Turhan
IDILKNUR DURUKAN
ILKNUR DURUKAN
AOArda Ozturkcan
Arda Ozturkcan
ZTZuhal Turgut
Zuhal Turgut


1 September 2011 in Microchemical Journal
Verified
Journal Article
Closed access
IDILKNUR DURUKAN
ILKNUR DURUKAN
ÇŞÇiğdem Arpa Şahin
Çiğdem Arpa Şahin
NŞNuray Şatıroğlu
Nuray Şatıroğlu
SBSema Bektaş
Sema Bektaş

15 January 2021 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
MYMaha Yahya
Maha Yahya
SKSare Kesekler
Sare Kesekler
IDILKNUR DURUKAN
ILKNUR DURUKAN
ÇAÇiğdem Arpa
Çiğdem Arpa
In this study ultrasound assisted-deep eutectic solvent-based liquid phase microextraction followed by microsampling-flame atomic absorption spectrometry was developed to determine prohibited lead and cadmium traces in hair dye and henna samples. For this purpose, deep eutectic solvent, prepared from choline chloride and phenol, was used as an extraction solvent, dithizone was used as a complexing agent, and THF was used as an aprotic solvent. All parameters that affect extraction efficiency, such as pH, the DES volume and composition, the extraction time, the amount of dithizone, were optimized. Under the optimal conditions, for Pb(II) and Cd(II), enhancement factors of 92 and 57, LODs of 2.5 μg L−1 and 0.75 μg L−1, LOQs of 7.8 μg L−1 and 2.5 μg L−1, linear working ranges of 10–250 μg L−1 and 2.5–50 μg L−1, were obtained, respectively. Relative standard deviation (n = 10) was calculated to be 2.7 for 100 μg L−1 of Pb(II) and 2.1 for 25 μg L−1 of Cd(II). The matrix effect was investigated by comparing the solvent-based calibration curve with the matrix-matched calibration curve. The determination of lead and cadmium in hair dye and henna samples without being affected by the sample matrix was successfully performed. The lead content was between 1.3 and 6.5 μg g−1, and the cadmium content was between 0.028 and 0.54 μg g−1 for the selected hair dye and henna samples.


2 July 2019 in Energy & Fuels
Verified
Journal Article
Closed access
EAEce Senol Akalin
Ece Senol Akalin
Young-Min KimYoung-Min Kim
Young-Min Kim
Koray ALPERKoray ALPER
Koray ALPER
VOVahur Oja
Vahur Oja
KTKubilay Tekin
Kubilay Tekin
SKSelhan Karagöz
Selhan Karagöz