“Polyurea coatings as a possible structural reinforcement system” is a research investigation that aims to explore the possible applications of polyurea coatings for improving structural performance (including steel, concrete, timber and other structures used in the construction industry). As part of the research in this field, this paper focuses on evaluating the performance of bending polyurea-coated reinforced concrete (RC) beams with a low reinforcement ratio. The easy application and numerous advantages of polyurea can prove very useful when existing RC structural elements are repaired or retrofitted. Laboratory tests of RC beams were performed for the purpose of this paper. The failure mechanisms and cracking patterns of these specimens are described, and their bending strengths were compared. On this basis, the effect of the coating on bending strength and the performance of the reinforced beams at the serviceability limit state (SLS) was examined and analyzed. The results showed that the use of a polyurea coating has a positive impact on the cracking and deflection state of RC beams and makes it possible to safely use RC elements on a continuous basis under high levels of load.
20 December 2017 in Civil and Environmental Engineering Reports
One of the methods to increase the load carrying capacity of the reinforced concrete (RC) structure is its strengthening by using carbon fiber (CFRP) strips. There are two methods of strengthening using CFRP strips - passive method and active method. In the passive method a strip is applied to the concrete surface without initial strains, unlike in the active method a strip is initially pretensioned before its application. In the case of a steel-concrete composite beam, strips may be used to strengthen the concrete slab located in the tension zone (in the parts of beams with negative bending moments). The finite element model has been developed and validated by experimental tests to evaluate the strengthening efficiency of the composite girder with pretensioned CFRP strips applied to concrete slab in its tension zone.
This work presented some selected results of laboratory tests and FEM analysis study of simple supported RC beams strengthened using carbon strips. The beams were examined to establish the effectiveness of this method of strengthening in terms of increasing their load-carrying capacity as well as flexural stiffness at different preloading states. A set of beams was divided into five groups, which differ in the level of the load applied before application of the composite strips on their bottom surfaces. Laboratory tests were supplemented with numerical analyses based on the finite-element method (FEM) using Abaqus software. The created numerical models were validated, and good agreement of the experimental results with the results obtained in the numerical analyses was observed. The deformation state existing in the main reinforcing bars, in concrete as well as in the strengthening composite strip, and its influence on the failure mechanism of the beams were analyzed. In the stiffness analysis, it was assumed that the stiffness of a beam strengthened with composite material after the elastic range (concrete and reinforcement steel) can be represented by the relation between the stiffness of the noncracked section B and beam curvature κ. The curvature–bending moment diagram as well as bending moment–stiffness diagram were prepared on the basis of laboratory and numerical results. Based on the results, it can be stated that the preload on the beam before strengthening affects the levels of deformation and the utilization rates of the composite material as well as reinforcing bars. The curvature and stiffness of the beams depend on the load level at which the CFRP strip strengthening is realized. The results of the analysis of preloaded beams before strengthening indicate that totally relieving them prior to strip application turns out to be the most beneficial solution.
In the paper the preliminary results of study on strengthening RC beams by means of CFRP materials under mixed shear-flexural work condition are presented. The Finite Element Method analyses were performed using numerical models proposed and verified earlier by the results of laboratory tests [4, 5] for estimation of effectiveness of CFRP strengthening of RC beams under flexure. The currently conducted analyses deal with 3D models of RC beams under mixed shear-flexural loading conditions. The symmetry of analyzed beams was taken into account (in both directions). The application of Concrete Damage Plasticity (CDP) model of RC beam allowed to predict a layout and propagation of cracks leading to failure. Different cases of strengthening were analyzed: with the use of CFRP strip or CFRP closed hoops as well as with the combination of above mentioned. The preliminary study was carried out and the first results were presented.