Katarzyna Rzeszut

Prof. Dr. Katarzyna Rzeszut

Poznan University of Technology, Faculty of Civil and Transport Engineering, Institut of Building Engineering
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
ISIlona Szewczak
Ilona Szewczak
Patryk RozyloPatryk Rozylo
Patryk Rozylo
Katarzyna RzeszutKatarzyna Rzeszut
Katarzyna Rzeszut
The paper presents a comparison of the effectiveness of strengthening steel thin-walled, cold-formed sigma beams with CFRP tapes and steel tapes. For this purpose, three beams without reinforcement (reference beams) of the “Blachy Pruszyński” type, with a cross-section of ∑200 × 70 × 2 and a span of 280 cm, made of S350GD steel grade, were subjected to laboratory tests in the four-point bending scheme. In the next stage the tests included nine ∑200 × 70 × 2 beams reinforced with Sika CarboDur S512 CFRP tape and six ∑200 × 70 × 2 beams reinforced with steel tape made of S235 steel grade. The length of the reinforcement tapes as well made of steel as well of CFRP was of 175 cm. The location of the tapes within the height of the beams’ cross-section was assumed in three variants, namely placing the tape on the upper or bottom flange and on the web. In the case of beams reinforced with CFRP, three beams were tested for each reinforcement location, and in the case of beams reinforced with steel tapes, two beams were tested for each reinforcement location. SikaDur®-30 glue with a thickness of 1.3 mm was used in order to connect steel or CFRP tapes to the beams. The dimensions of the tapes cross-sections in both cases were similar (CFRP tapes: 50 × 1.2 mm, steel tapes: 50 × 1.3 mm). For all types of beams, numerical models were also developed in the Abaqus software. The main aim of this paper was investigation of the influence of mechanical properties of steel or CFRP tapes on the effectiveness of strengthening ∑ beams. For this purpose a comparison of these two solutions with respect to the limitation of displacements and deformations of the beam was performed. The obtained results were considered in the context of the mechanical properties of the materials composing the reinforcement tapes. The tests showed slight differences in the results of strain and displacements obtained for reinforcement made of two different materials. It was also noted that the decisive element was the failure of the joint at the steel-glue interface. Therefore, future studies will pay particular attention to the adhesive layer.

8 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
ISIlona Szewczak
Ilona Szewczak
Patryk RozyloPatryk Rozylo
Patryk Rozylo
MSMalgorzata Snela
Malgorzata Snela
Katarzyna RzeszutKatarzyna Rzeszut
Katarzyna Rzeszut
This paper presents selected issues related to the reinforcement of steel element cold-formed with CFRP tapes. The first section of the paper is a review of source literature and a presentation of the basic information on cold-formed thin-walled steel elements and CFRP composite materials, stressing the advantages and disadvantages of using them to reinforce steel structures. Next, the authors present original research on reinforcing bent thin-walled sigma-type steel beams using adhesive CFRP tapes. Reference beams with a cross-section of Σ200 × 70 × 2 and a length of 3 m, reinforced with CFRP tape, were tested in the four-point bending scheme. Then, the paper discusses a developed numerical model that is consistent with the subject matter of the laboratory tests. The developed numerical model was prepared to represent the failure of the connection between the beam and the composite tape. This was followed by a number of numerical analyses in order to determine the optimum adhesive layer that would allow us to achieve the maximum reduction of the displacements and strains in bent thin-walled sigma-type beams. Three thicknesses of the SikaDur adhesive layer were analyzed in the study. Based on the analyzes, it was found that the increase in the thickness of the adhesive layer slightly reduced the strain and displacement in the beams, but caused a significant decrease in the load value, at which damage appeared in the glued joint.

4 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
Jacek SzafranJacek Szafran
Jacek Szafran
AMArtur Matusiak
Artur Matusiak
Katarzyna RzeszutKatarzyna Rzeszut
Katarzyna Rzeszut
IJIwona Jankowiak
Iwona Jankowiak
“Polyurea coatings as a possible structural reinforcement system” is a research investigation that aims to explore the possible applications of polyurea coatings for improving structural performance (including steel, concrete, timber and other structures used in the construction industry). As part of the research in this field, this paper focuses on evaluating the performance of bending polyurea-coated reinforced concrete (RC) beams with a low reinforcement ratio. The easy application and numerous advantages of polyurea can prove very useful when existing RC structural elements are repaired or retrofitted. Laboratory tests of RC beams were performed for the purpose of this paper. The failure mechanisms and cracking patterns of these specimens are described, and their bending strengths were compared. On this basis, the effect of the coating on bending strength and the performance of the reinforced beams at the serviceability limit state (SLS) was examined and analyzed. The results showed that the use of a polyurea coating has a positive impact on the cracking and deflection state of RC beams and makes it possible to safely use RC elements on a continuous basis under high levels of load.

29 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
ISIlona Szewczak
Ilona Szewczak
Katarzyna RzeszutKatarzyna Rzeszut
Katarzyna Rzeszut
Patryk RozyloPatryk Rozylo
Patryk Rozylo
Sylwester SamborskiSylwester Samborski
Sylwester Samborski
In this paper, the retrofitting method of thin-walled, cold-formed sigma beams using bonded carbon fibre reinforced polymer (CFRP) tapes is proposed. The effectiveness of the presented strengthening method is investigated by the means of laboratory tests and numerical analysis conducted on simply supported, single-span beams made of 200 × 70 × 2 profile by “Blachy Pruszyński” subjected to a four-point bending scheme. Special attention is paid to the evaluation of possibility to increase the load capacity with simultaneous limitation of beams displacements by appropriate location of CFRP tapes. For this purpose, three beams were reinforced with CFRP tape placed on the inner surface of the upper flange, three with CFRP tape on the inner surface of the web, three beams with reinforcement located on the inner surface of the bottom flange, and two beams were tested as reference beams without reinforcement. CFRP tape with a width of 50 mm and a thickness of 1.2 mm was used as the reinforcement and was bonded to the beams by SikaDur®-30 adhesive. Precise strain measurement was made using electrofusion strain gauges, and displacement measurement was performed using two Aramis coupled devices in combination with the Tritop machine. Numerical models of the considered beams were developed in the Finite Element Method (FEM) program Abaqus®. Experimental and numerical analysis made it possible to obtain a very high agreement of results. Based on the conducted research, it was proved how important is the impact of the applied reinforcement (CFRP tapes) in thin-walled steel structures, with respect to the classic methods of strengthening steel building structures.

8 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Katarzyna RzeszutKatarzyna Rzeszut
Katarzyna Rzeszut
In this paper, the stability of steel members with a complex initial geometrical imperfection pattern are analysed. This issue is extremely important in the case of slender structures, characterised by multiple close critical loads and modal interactions, which can lead to unstable post-critical paths and imperfection sensitivity. Despite the fact that the loss of stability, as a result of complex geometrical imperfections, is a very common mechanism for the destruction of slender steel structures, there is still no unambiguous and adequate research in the literature and in scientific research taking into account multimodal buckling. Therefore, in this study, special attention was focused on the analysis of the equilibrium path of the structure in the pre- and post-buckling range. This was studied by introducing a model of a structure composed of four rigid bars connected by elastic nodes. For this model, as well as for the structure with and without initial geometrical imperfections, a set of nonlinear algebraic equations of equilibrium was developed. A complex pattern of imperfections was taken into account using a linear superposition of buckling modes obtained from a linear eigenvalue problem. In order to investigate the nature of bifurcation points, the concept of minimum of potential energy was adopted. By means of numerous examples, the influence of imperfections on the structural behaviour was discussed. It was found that, for special imperfection patterns, an increase in the amplitude of initial geometrical imperfection can result in an increase in the value of the critical load defining the bifurcation point. In these cases, initial geometrical imperfections can play a positive role, resulting in stable post-buckling behaviour. This phenomenon corresponds with the so-called “modal nudging” which aims to improve the buckling response of slender elastic structures by introducing a small disturbance in the primary geometry of the structure, which results in equilibrium paths of greater load-carrying capacity. Among other observations, a snap-through phenomenon caused by transition from the local to the global minimum of potential energy was also noted. The observed snap-through was caused by the specific configuration of initial geometrical imperfections, which in this case played quite a dangerous role. It should be emphasised that the proposed model structure allows for a full description of the post-critical behaviour and a trace of the influence of complex imperfection configurations in a simple and clear manner.

Verified
Journal Article
Open access
PDF file
Maria Amélia Ramos LojaMaria Amélia Ramos Loja
Maria Amélia Ramos Loja
Katarzyna RzeszutKatarzyna Rzeszut
Katarzyna Rzeszut
JBJoaquim Infante Barbosa
Joaquim Infante Barbosa
This work aims to analyse the free-vibration response of functionally graded, simply supported beams with different gradient directions, taking into account nonlocal effects. To this purpose, the first-order shear deformation theory and the nonlocal elasticity theory of Eringen are used, in order to assess the influence of size dependency effects on the free-vibration responses of those beams. The influence of other factors such as the aspect ratio of the beams and the evolution of the constituents’ mixture through the beam thickness and along its length is also considered. In this last case, a mixture distribution is proposed, accounting for the boundary conditions’ characteristics. The finite element model is first verified against existing alternative solutions, to assess and illustrate its performance. Based on the conclusions achieved, a set of parametric studies is then developed. The results are discussed considering the material distribution profiles, and conclusions are drawn with respect to their relative performance under the analysed conditions.