This investigation aimed to evaluate the antibacterial effect of polymeric nanoparticles (NPs), functionalized with calcium, zinc, or doxycycline, using a subgingival biofilm model of six bacterial species (Streptococcus oralis,Actinomyces naeslundii, Veillonela parvula, Fusobacterium nucleatum, Porphyromonas gingivalis, and Aggregatibacter actinomycetemcomitans) on sandblasted, large grit, acid-etched titanium discs (TiDs). Undoped NPs (Un-NPs) or doped NPs with calcium (Ca-NPs), zinc (Zn-NPs), or doxycycline (Dox-NPs) were applied onto the TiD surfaces. Uncovered TiDs were used as negative controls. Discs were incubated under anaerobic conditions for 12, 24, 48, and 72 h. The obtained biofilm structure was studied by scanning electron microscopy (SEM) and its vitality and thickness by confocal laser scanning microscopy (CLSM). Quantitative polymerase chain reaction of samples was used to evaluate the bacterial load. Data were evaluated by analysis of variance (p < 0.05) and post hoc comparisons with Bonferroni adjustments (p < 0.01). As compared with uncovered TiDs, Dox-NPs induced higher biofilm mortality (47.21% and 85.87%, respectively) and reduced the bacterial load of the tested species, after 72 h. With SEM, scarce biofilm formation was observed in Dox-NPs TiDs. In summary, Dox-NPs on TiD reduced biofilm vitality, bacterial load, and altered biofilm formation dynamics.
Surface chemistry evaluation is crucial in assessing the efficacy of chemical decontamination products for titanium implants. This study aimed to investigate the effectiveness of chemical decontamination solutions in cleaning a contaminated dental implant surface and to evaluate the potential of combining Pluronic gel with hydrogen peroxide (NuBone®Clean) by evaluating pellicle disruption and re-formation on implant surfaces. In addition, ensuring safety with in vitro and human testing protocols. X-ray Photoelectron Spectroscopy (XPS) was utilised for surface analysis. All the tested gels had some effect on the surface cleanness except for PrefGel®. Among the tested chemical decontamination candidates, NuBone®Clean demonstrated effectiveness in providing a cleaner titanium surface. Furthermore, none of the tested chemical agents exhibited cytotoxic effects, and the safety assessment showed no adverse events. The results of this study highlight the significance of conducting comprehensive evaluations, encompassing safety and efficacy, before introducing new chemical agents for dental treatments. The findings suggest that NuBone®Clean shows potential as a chemical decontamination solution for implant surfaces. However, further investigation through randomised clinical trials is necessary. By adhering to rigorous testing protocols, the development of safe and efficient chemical decontamination strategies can be advanced, benefiting patients and promoting progress in implant dentistry.
22 October 2024 in Journal of Periodontal Research
Aim: To assess the correlation between micro‐computed tomography (micro‐CT) and linear morphometric measurements in terms of mandibular bone levels in a modified experimental periodontitis model in rodents to study the mechanisms of association between periodontal destruction and neuroinflammation.Methods: The proposed in vivo experimental periodontitis model involves the administration of oral rinses with Porphyromonas gingivalis and Fusobacterium nucleatum, four times per week during 4, 8 or 12 weeks, in 24 male Wistar Hannover rats (180 g, 5 weeks old). After euthanasia, hemi‐mandibles were collected. One hemi‐mandible was analysed using morphometry, while the other was assessed with micro‐CT. Linear measurements were taken at the buccal aspect and furcation level for both techniques, and volumetric measurements were also obtained with micro‐CT. Passing–Bablok regression analysis was used to compare the results of both techniques, with morphometric measurements serving as the reference. Moreover, Lin's Concordance correlation coefficient was calculated to assess the level of agreement. Periodontal clinical variables with neuroinflammatory parameters from the frontal cortex were used to evaluate the association between the resulting condition and neuroinflammation.Results: Twenty‐one out of the initial 24 rats were analysed. The micro‐CT linear measurements demonstrated high concordance values with the linear morphometric measurements at the buccal surfaces of the roots in molars (r = 0.714) but not at the furcation area (r = 0.052). At 12 weeks, there was a significant impact on neuroinflammation with significant decreases in iNOS levels and p‐mTOR levels at 4 and 8 weeks.Conclusion: The proposed in vivo experimental periodontitis model demonstrated a high degree of correlation between morphometric and micro‐CT measurements in buccal areas but not at the furcation level. Concomitantly, there was a significant temporary modulation of the neuroinflammatory response.
Surface chemistry evaluation plays a crucial role in assessing the efficacy of chemical decontamination products for titanium implants. This study aimed to investigate the effectiveness of chemical decontamination solutions in cleaning a contaminated dental implant surface and to evaluate the potential of combining Pluronic gel with hydrogen peroxide (NuBone®Clean) by evaluating pellicle disruption and re-formation on implant surfaces. In addition, ensuring safety with in- vitro and human testing protocols. X-ray Photoelectron Spectroscopy (XPS) was utilized for surface analysis. All the tested gels had some effect on the surface cleanness except for PrefGel®. Among the tested chemical decontamination candidates, NuBone®Clean demonstrated effectiveness in providing a cleaner titanium surface. Furthermore, none of the tested chemical agents exhibited any cytotoxic effects, and the safety assessment showed no adverse events. The results of this study highlight the significance of conducting comprehensive evaluations, encompassing safety and efficacy, before introducing new chemical agents for dental treatments. The findings suggest that NuBone®Clean shows potential as a chemical decontamination solution for implant surfaces. However, further investigation through randomized clinical trials is necessary. By adhering to rigorous testing protocols, the development of safe and efficient chemical decontamination strategies can be advanced, benefiting patients and promoting progress in the field of implant dentistry.
About Me
DDS; MSD; Certificate of Completion of Specialised Training (CCST) in Periodontology by the EFP; PhD Candidate.
DDS; MSD; Certificate of Completion of Specialised Training (CCST) in Periodontology by the EFP; PhD Candidate.