João Arthur Alcântara

Prof. Dr. João Arthur Alcântara

IPCCB, Fundação de Medicina Tropical, Manaus, Amazonas, Brazil
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2021 in PLOS Neglected Tropical Diseases
Verified
Journal Article
Open access
PDF file
GSGuilherme Kemeron Maciel Salazar
Guilherme Kemeron Maciel Salazar
JCJoseir Saturnino Cristino
Joseir Saturnino Cristino
ASAlexandre Vilhena Silva-Neto
Alexandre Vilhena Silva-Neto
AFAltair Seabra Farias
Altair Seabra Farias
JAJoão Arthur Alcântara
João Arthur Alcântara
JSJacqueline de Almeida Gonçalves Sachett
Jacqueline de Almeida Gonçalves Sachett
In the Brazilian Amazon, long distances, low healthcare coverage, common use of ineffective or deleterious self-care practices, and resistance to seeking medical assistance have an impact on access to antivenom treatment. This study aimed to estimate snakebite underreporting, and analyze barriers that prevent victims from obtaining healthcare in communities located in 15 municipalities on the banks of the Solimões, Juruá and Purus Rivers, in the remote Western Brazilian Amazon. Information on the participants’ demographics, previous snakebites, access to healthcare, time taken to reach medical assistance, use of self-care practices, and the reason for not accessing healthcare were collected through semi-structured interviews. In the case of deaths, information was collected by interviewing parents, relatives or acquaintances. A total of 172 participants who reported having suffered snakebites during their lifetime were interviewed. A total of 73 different treatment procedures was reported by 65.1% of the participants. Participants living in different river basins share few self-care procedures that use traditional medicine, and 91 (52.9%) participants reported that they had access to healthcare. Living in communities along the Juruá River [OR = 12.6 (95% CI = 3.2–49.7; p<0.001)] and the use of traditional medicine [OR = 11.6 (95% CI = 3.4–39.8; p<0.001)] were variables that were independently associated to the lack of access to healthcare. The main reasons for not accessing healthcare were the pprioritization of traditional treatments (70.4%), and the failure to recognize the situation as being potentially severe (50.6%). Four deaths from complications arising from the snakebite were reported, and three of these were from communities on the banks of the Juruá River. Only one of these received medical assistance. We found an unexpectedly high underreporting of snakebite cases and associated deaths. Snakebite victims utilized three main different healing systems: 1) self-care using miscellaneous techniques; 2) official medical healthcare generally combined with traditional practices; and 3) self-care using traditional practices combined with Western medicines. To mitigate snakebite burden in the Brazilian Amazon, an innovative intervention that would optimize timely delivery of care, including antivenom distribution among existing community healthcare centers, is needed.

28 May 2022 in Toxins
Verified
Journal Article
Open access
PDF file
Gisele dos Santos RochaGisele dos Santos Rocha
Gisele dos Santos Rocha
AFAltair Seabra Farias
Altair Seabra Farias
JAJoão Arthur Alcântara
João Arthur Alcântara
VMVinícius Azevedo Machado
Vinícius Azevedo Machado
FMFelipe Murta
Felipe Murta
Wuelton MonteiroWuelton Monteiro
Wuelton Monteiro
Snakebite envenoming (SBE) is a neglected tropical disease with significant global morbidity and mortality. Even when antivenom is available in low-resource areas, health workers do not receive adequate training to manage SBEs. This study aims to develop and validate a clinical practice guideline (CPG) for SBE management across Brazil. A panel of expert judges with academic and/or technical expertise in SBE management performed content validation. The content validity index (CVI) score was 90% for CPG objectives, 89% for structure and presentation and 92% for relevance and classified the CPG as valid. A semantic validation was performed by analyzing focus group discussions with doctors and nurses from three municipalities of the Brazilian Amazon, after a 5-day meeting during which the CPG was presented. Two central themes emerged: knowledge acquired during the meeting and recommendations for improving the CPG. Based on these results, the CPG was revised into a final version. This study presents the successful development and validation process of a CPG for SBE management, which is targeted to a specific low-resource, high-burden setting. This development and validation process can be adapted to other settings and/or other neglected tropical diseases.

1 September 2020 in Wilderness & Environmental Medicine
Verified
Journal Article
Closed access
JSJacqueline de Almeida Gonçalves Sachett
Jacqueline de Almeida Gonçalves Sachett
FAFernando Almeida-Val
Fernando Almeida-Val
JAJoão Arthur Alcântara
João Arthur Alcântara
NCNadia Cubas-Vega
Nadia Cubas-Vega
CMChristielle S. Montenegro
Christielle S. Montenegro
Wuelton MonteiroWuelton Monteiro
Wuelton Monteiro
Snakebites are a neglected and underestimated global health hazard. In the Brazilian Amazon, Bothrops snakebites are the most prevalent and may lead to severe complications. Here we describe a severe case of Bothrops atrox snakebite that, owing to delayed medical assistance, presented with renal and respiratory failure, compartment syndrome, and tissue necrosis. After several fasciotomy surgeries, the patient survived; however, he showed significant functional disability. Prompt management of snake envenomation would aid in the early diagnosis of local and systemic complications and, consequently, would result in a better functional outcome with improved quality of life.

17 March 2023 in Viruses
Verified
Journal Article
Open access
PDF file
APAndréia da Costa Paz
Andréia da Costa Paz
BCBárbara Chaves
Bárbara Chaves
RGRaquel Soares Maia Godoy
Raquel Soares Maia Godoy
DCDeilane Ferreira Coelho
Deilane Ferreira Coelho
AJAdemir Bentes Vieira Júnior
Ademir Bentes Vieira Júnior
PPPAULO PIMENTA
PAULO PIMENTA
Zika virus (ZIKV) is transmitted to humans by the infectious bite of mosquitoes such as Aedes aegypti. In a city, the population control of mosquitoes is carried out according to alerts generated by different districts via the analysis of the mosquito index. However, we do not know whether, besides mosquito abundance, the susceptibility of mosquitoes could also diverge among districts and thus impact the dissemination and transmission of arboviruses. After a viremic blood meal, the virus must infect the midgut, disseminate to tissues, and reach the salivary gland to be transmitted to a vertebrate host. This study evaluated the patterns of ZIKV infection in the Ae. aegypti field populations of a city. The disseminated infection rate, viral transmission rate, and transmission efficiency were measured using quantitative PCR at 14 days post-infection. The results showed that all Ae. aegypti populations had individuals susceptible to ZIKV infection and able to transmit the virus. The infection parameters showed that the geographical area of origin of the Ae. aegypti influences its vector competence for ZIKV transmission.

18 March 2026 in JMIR Formative Research
Verified
Journal Article
Open access
AFAlexandre Ferreira
Alexandre Ferreira
AIAllan Inoue
Allan Inoue
RBRamon Ludman Martins Barbosa
Ramon Ludman Martins Barbosa
CHCassio Hayek
Cassio Hayek
MRMateus Reis
Mateus Reis
MSMarcelo Rodrigues dos Santos
Marcelo Rodrigues dos Santos
Background: Smartwatches have gained popularity for their potential to provide accurate measurements of various physiological parameters. However, the validity of energy expenditure (EE) across different smartwatch models remains a topic of ongoing investigation. Discrepancies between results obtained from different models and gold standard methods are particularly critical across varying exercise intensities and types, as validation studies have demonstrated overestimation when wearable activity monitors are compared with indirect calorimetry. Objective: This study investigated the accuracy of 2 versions of the Samsung smartwatch (Galaxy Watch [GW] 6 and 7) in measuring EE during intermittent moderate-intensity running exercises, using indirect calorimetry as the gold standard method. Methods: This study included 148 healthy adults, comprising 80 men and 68 women. Participants performed intermittent treadmill running, consisting of walking at 5 km·h⁻¹ for 1 minute and running between 8 and 16 km·h⁻¹ for 2 minutes, based on participant preference, for a total duration of 27 minutes. The GW6 and GW7 models were used and EE was measured by indirect calorimetry using a wearable portable metabolic gas analysis system (K5; Cosmed), which is considered a gold standard method. Results: No statistically significant differences were found between the GW models and the K5. The K5 showed a mean EE of 213.60 (SD 43.04) kilocalories, compared with 219.53 (SD 35.70) kilocalories for the GW6 and 202.67 (SD 47.42) kilocalories for the GW7 (all P >.05). Good Spearman correlations (0.63‐0.70) and moderate intraclass correlation coefficients (0.65‐0.74) were found. Mean absolute percentage error values ranged from 10.10% to 12.55%. Bland-Altman analysis revealed limits of agreement for all comparisons (K5 vs GW6 and GW7, −61.93 to 65.80 kcal). Conclusions: The GW6 and GW7 devices showed moderate validity for estimating EE during intermittent running exercises, demonstrating the suitability of the GW as a low-cost and practical wearable option for daily physical activities.

16 April 2026 in JMIR Cardio
Verified
Journal Article
Open access
AIAllan Inoue
Allan Inoue
JSJoão Paulo Ferreira Soares
João Paulo Ferreira Soares
FSFelipe Santos
Felipe Santos
AFAlexandre Ferreira
Alexandre Ferreira
AGAlberto Gonçalves
Alberto Gonçalves
MSMarcelo Rodrigues dos Santos
Marcelo Rodrigues dos Santos
Background: Photoplethysmography-based smartwatches are increasingly used for continuous heart rate (HR) monitoring. Their accuracy has been demonstrated at rest or during low-intensity activity, but data are scarce for maximal-intensity exercise, when motion artifacts and rapid hemodynamic changes can degrade the photoplethysmography signal. Validating these devices under such demanding conditions is essential before they are applied to clinical exercise testing, athletic training, or remote health monitoring. Objective: This study aimed to evaluate the validity of the Samsung Galaxy Watch 6 (GW6) in estimating HR throughout a graded, maximal ramp cardiopulmonary exercise test performed on a treadmill. A secondary aim was to explore whether measurement error varies across 5 predefined intensity zones (50%‐60%, 60%‐70%, 70%‐80%, 80%‐90%, and 90%‐100% of the maximum HR determined individually for each participant). Methods: Overall, 55 healthy adults (30 men, 25 women; mean age 30.3, SD 8.2 years) completed a symptom-limited incremental treadmill protocol to volitional exhaustion. Simultaneous HR recordings were obtained from the GW6 (left arm) and a Polar H10 chest strap monitor, which served as the reference standards. For each intensity zone, the following agreement indices were computed: intraclass correlation coefficient (ICC), median absolute error, median absolute percentage error, and root mean squared error. Bland-Altman analysis was performed to quantify the mean bias and 95% limits of agreement between the GW6 and the Polar H10. Statistical significance was set at P <.05. Results: Agreement between the GW6 and Polar H10 varied across exercise intensities. ICC indicated moderate to good agreement at low to moderate intensities (ICC=0.71 at 50%‐60%; ICC=0.89 at 60%‐70%; ICC=0.54 at 70%‐80%; and ICC=0.64 at 80%‐90% HRmax), and at 90%‐100% of HRmax the agreement was good-to-excellent (ICC=0.90). Absolute error metrics showed stable or reduced errors with increasing intensity, with median absolute error consistently around 1‐3 bpm and median absolute percentage error declining from 2.90% at 50%‐60% HRmax to 0.60%‐0.75% at ≥70% HRmax. Root mean squared error ranged from 4.62 to 4.88 bpm across intensity zones. Bland-Altman analysis showed that the GW6 consistently underestimated HR compared with the Polar H10, with an overall mean bias of −2.67 bpm and wide limits of agreement (−16.90 to 11.57 bpm). This negative bias was present across all HR zones. The agreement was adequate for group-level comparisons but displayed substantial individual variability. Conclusions: The GW6 provides a good degree of validity for HR monitoring during a maximal treadmill cardiopulmonary exercise test in healthy young adults. Although measurement error increases modestly at near-maximal workloads, absolute errors remain well within clinically acceptable thresholds. These findings support the potential use of GW6 as a convenient, noninvasive alternative for HR tracking in laboratory-based exercise testing.