This paper focuses on the islanding transition of an AC microgrid equipped with a doubly-fed induction generator wind turbine, a photovoltaic unit, a battery energy storage system (BESS) and local loads. It is well known that the islanding transition put at risk system stability, especially for the systems with low inertia. This paper has explored the combined contribution of virtual inertia support schemes applied to the BESS and to the DC-link capacitor of the back-to-back inverter of the wind power generator in order to ensure a smooth islanding transition by preserving the microgrid stability. For this purpose, we analyse the frequency/inertia support provided by two virtual inertia control schemes: i) a virtual synchronous generator technique on the BESS and ii) a DC-link capacitor control. The analysis is carried out by using time domain simulations in the DIgSILENT PowerFactory environment.
This paper presents the main findings, problems encountered, and solutions regarding the dynamic stability of future network operation scenarios in the presence of a high amount of clean, converter-based energy sources (renewables, storage, etc.) as studied within the OSMOSE European project. This study has been carried out on a portion of the Italian transmission grid where the most recent and innovative flexibility services have been implemented to preserve the dynamic stability for the scenarios selected. The most typical and critical generation/demand conditions have been recreated on the Sicilian grid for 2030 and checked. This research proves that in the future, different services, like synthetic inertia from renewable energy sources, flexible demand response, or reactive power provision from static converters, must be taken into account to preserve system stability as traditional generators are progressively phased out.
To address the decreasing power system inertia challenges due to the increasing penetration of Renewable Energy Sources (RESs), this paper proposes a Fast Frequency Response (FFR) technique for wind turbines equipped with Doubly Fed Induction Generators (DFIG). The DC-link of a DFIG unit can be controlled to partially exchange energy in case of frequency transients, thus providing FFR that in turn helps maintain grid stability. This control is achieved by levelling up or down the DC-link voltage. Supercapacitor units connected to the DC-link provide the required energy for FFR services. We perform a detailed analysis to achieve the expressions of the minimum DC-link voltage required for the proper operation of the grid side converter and the factors affecting its value. We then propose a procedure to estimate the optimal value for FFR controller gain and a DC-link protection scheme that decouples the FFR controller design from the grid characteristics. The method can be applied to any RES using converter with sufficient energy buffer in order to provide FFR service.
This paper investigates the impact of high penetration of wind power plants equipped with Doubly Fed Induction Generators (DFIGs) on the power system stability. A Fast Frequency Response service, obtained by using supercapacitor units connected at the DC-link of DFIG turbines, and its influence on the transient and small signal stability is proposed and analyzed. A procedure for determining the supercapacitors size based on required equivalent inertia is presented. Time domain simulation results and eigenvalue analysis are performed to assess the response of a system with four generating units after perturbations of the power balance. A coherency-based reduction technique is employed to limit the analysis to the only area of interest. The obtained results show that the frequency response of the system is not impaired if synchronous generators are replaced by DFIGs providing FFR services.
In this paper, the concept of virtual synchronous generator (VSG) which provides grid following converters the dynamic frequency support capability is analyzed. A frequency controller that responds to both frequency deviation and frequency derivative generates the active power reference required to emulate the droop response (DR) and inertial response (IR) characteristics similar to a traditional synchronous generator (SG) for the VSG. First, a theoretical validation of the impact of DR and IR of the VSG unit on frequency response is presented. Then, the influence of the VSG parameters, i.e., (a) DR and IR gains, (b) active power reserve, (c) response time and (d) frequency controller deadband on the frequency stability of a medium voltage microgrid (MG) during load step events has been analyzed using simulation. The minimum frequency (fmin) and maximum rate of change of frequency (RoCoF max ) are used as the transient stability performance indicators. The studies are performed in the DIgSILENT PowerFactory simulation platform.