Gate oxide degradation, which considerably affects turn- on /- off dynamics of the switch, embraces a large percentage of chip-related failure modes both in silicon and silicon carbide power MOSFETs. The gate oxide layer is thinner in silicon carbide power MOSFETs in comparison to their silicon-based counterparts. Consequently, the problem of gate oxide degradation has become a more crucial impediment in achieving reliable performance in silicon carbide power MOSFETs. This problem is even more severe in high-frequency applications due to higher EMI signature and complicated and costly measurement. In this article, a reliable fully analog cost-effective gate oxide degradation condition monitoring technique is proposed and validated. High-order harmonics magnitudes of drain–source voltage are used to produce a dc signal as the aging precursor of the gate oxide region. Using a dedicated degradation setup, the credibility of the developed condition monitoring technique was examined at different rates of gate oxide degradation for 650-V/22-A silicon carbide discrete MOSFET. In 200-kHz, 217-V switch operation, the proposed precursor showed 68% change in comparison to its initial value. This brings a high-resolution assessment on the reliability level of the switch gate oxide region.
Like the widely-used semiconductor switch, Insulated Gate Bipolar Transistors (IGBTs) are subject to many failures and degradation in power electronic converters. In Short Circuit Fault (SCF), as the most reported failures in IGBTs, drastic, sudden temperature rise, and peak SCF current are widespread failures owing to a relatively long delay of the protection subsystem. This paper proposes a protection strategy to limit the junction temperature rise by limiting the SCF current by adding a small value resistor in the IGBT emitter. Second, it reduces the SCF current to a value much less than the saturated current. With the proposed control approach, sudden temperature rise during SCF is controlled, preventing significant failure in IGBTs. The extension of the permissible SCF time is achieved even for the cases with temporary arcs. A simple control loop activates in the SCF condition and does not create slow transients for the IGBT. The results of this paper are validated through simulation and experiment.
26 September 2023 in IEEE Transactions on Power Electronics
Condition monitoring (CM) of the components with highest probability of failure in converter circuits can significantly contribute to having a long-term reliable operation. Insulated-gate bipolar transistors (IGBTs) are considered as one of the most fragile parts with the highest failure rates in many power electronics applications. This article proposes a real-time CM technique for assessing the IGBT gate oxide degradation level. The proposed technique is based on the device turn- off delay time interval, which as we discovered, decreases during the device gate oxide degradation (DGOD) process. Therefore, this article proposes a practical fully analogue circuit to capture the device turn- off delay time and convert it to a dc voltage as the final output of the CM circuit. The DGOD precursor output can be effectively used to assess the health status of IGBT gate oxide layer during the device real-time operation. Two different types of 600 V/60 A discrete IGBTs from different manufacturers are used in the experimental verification process. In addition, the proposed CM technique is applied to a 500 W boost dc–dc converter to evaluate the applicability of the proposed CM technique to real-world converter operation. The results indicate that the proposed DGOD precursor shows a 50% change when the device experiences full gate oxide degradation.
6 March 2019 in IEEE Transactions on Dielectrics and Electrical Insulation
The lack of turn-off ability makes the spark gap-based Marx generator uncontrollable in terminating the output pulse. In addition, there are some limitations for rise time and voltage gain improvements in the conventional critically-damped Marx design. In this paper, an efficient over-damped design of Marx circuit is proposed, which leads to a shorter rise time as well as a larger voltage gain. A chopping magnetic switch is employed to achieve the desired values of the fall time and full width at half maximum (FWHM). Moreover, adding a DC bias circuit to the magnetic switch provides the ability to adjust the pulse FWHM parameter. Therefore, an output pulse with a shorter rise time, larger voltage gain, and controllable FWHM is achieved. The finite element method is utilized to simulate the structures, and the proposed scheme is evaluated by practical experiments.
Current distribution anomaly can be used to indicate the onset of package-related failures modes in Silicon Carbide power MOSFET modules. In this paper, we propose to obtain the wire bond’s magnetic field profile using an array of Tunnel Magneto-Resistance (TMR) sensors, and characterise the small changes in the current density distribution to find the onset of the wire bond degradation processes, including wire bond lift-off, wire bond cracking, and wire bond fracture. We propose a novel condition monitoring technique where a non-galvanic high-bandwidth sensing and a reliability model monitor the health of the power switches. We designed a dedicated calibration set-up to examine the sensor array and calibrated to demonstrate the adequate sensitivity to a minimum 5% current anomaly detection in a single wire bond of the switching devices operating with 50 kHz switching frequency. We use a hardware-in-the-loop (HIL) experimental set-up to replicate wire bond-related failures in a 1200 V/55 A SiC MOSFET power module of a DC/DC Boost converter. Signal conditioning circuits are further designed to amplify and buffer the sensor readings. Experimental results showed the proposed technique is able to detect a wide range of package-related failures.
High frequency transformer is an important component in lots of modern power electronic circuits. In order to analyze the behavior of these transformers, equivalent circuit models containing parasitic elements have been proposed. But most of them are complicated and not appropriate to use in processes in which high speed analysis is crucial. In this paper, a second-order simplified model for high frequency transformers is obtained. Besides, the frequency ranges in which the proposed model has enough precision, are calculated and examined. To validate the simplified circuit model, some simulations are carried out. During the simulation, the effects of transformer equivalent circuit parameters on the limits of valid frequencies are investigated. Afterwards, the behavior of a real transformer is investigated to confirm the validation of the proposed circuit model and obtained frequency ranges.