Jesús Trigo

Dr. Jesús Trigo

Public University of Navarra
+2
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
PMPilar Muñoz
Pilar Muñoz
Jesús TrigoJesús Trigo
Jesús Trigo
Ignacio Martínez RuizIgnacio Martínez Ruiz
Ignacio Martínez Ruiz
ACAdolfo Muñoz Carrero
Adolfo Muñoz Carrero
JEJavier Escayola
Javier Escayola
José GarcíaJosé García
José García
The standardization of Electronic Health Records (EHR) is a crucial factor for ensuring interoperable sharing of health data. During recent decades, a plethora of initiatives ‐ driven by international organizations ‐ has emerged to define the required models describing the exchange of information between EHRs. These models cover different essential characteristics for building interoperable EHRs, such as architecture, methodology, communication, safety or terminology, among others. In this context, the European reference frame for the standardized exchange of EHR is the recently approved ISO/EN 13606 standard. This multi‐part standard provides the syntactic and semantic capabilities (through a dual model approach) as well as terminology, security and interface considerations for the standardized exchange of EHR. This paper provides (a) an introduction to the different standardization efforts related to the interoperable exchange of EHR around the world, and (b) a description of how the ISO/EN 13606 standard provides interoperable sharing of clinical information.

1 April 2016 in Journal of Biomedical Informatics
Verified
Journal Article
Closed access
OMOscar Jesus Rubio Martin
Oscar Jesus Rubio Martin
Jesús TrigoJesús Trigo
Jesús Trigo
AAAlvaro Alesanco
Alvaro Alesanco
Luis SerranoLuis Serrano
Luis Serrano
José GarcíaJosé García
José García

1 December 2010 in Telemedicine and e-Health
Verified
Journal Article
Closed access
Ignacio Martínez RuizIgnacio Martínez Ruiz
Ignacio Martínez Ruiz
JEJavier Escayola
Javier Escayola
MMMiguel Martínez-Espronceda
Miguel Martínez-Espronceda
PMPilar Muñoz
Pilar Muñoz
Jesús TrigoJesús Trigo
Jesús Trigo
José GarcíaJosé García
José García
The new paradigm of personal health demands open standards and middleware components that permit transparent integration and end-to-end interoperability from new personal health devices to healthcare information system. The use of standards seems to be the internationally accepted way to face this challenge. In this article, the implementation of an end-to-end standard-based personal health solution is presented. It integrates the ISO/IEEE11073 standard for the interoperability of personal health devices in the patient environment and the ISO/EN13606 standard for the interoperable exchange of electronic healthcare records and proposes a new approach for the end-to-end ISO/IEEE11073–ISO/EN13606 communication. The design strictly fulfills all the technical requirements of the most recent versions of both standards. An entire prototype has been designed, developed, and tested as a proof-of-concept of a personal health solution. An end-to-end standard-based personal health solution integrated the ISO/IEEE11073 standard for interoperability of personal health devices in the patient environment and the ISO/EN13606 standard for the interoperable exchange of electronic healthcare records. A new approach for end-to-end ISO/IEEE11073–ISO/EN13606 communication was designed that fulfills all the technical requirements of the most recent versions of both standards. The prototype was tested as a proof of concept of a personal health solution with acceptable outcomes.

9 August 2010 in IEEE Transactions on Information Technology in Biomedicine
Verified
Journal Article
Closed access
Jesús TrigoJesús Trigo
Jesús Trigo
FCFranco Chiarugi
Franco Chiarugi
AAAlvaro Alesanco
Alvaro Alesanco
MMMiguel Martínez-Espronceda
Miguel Martínez-Espronceda
LSLuis Serrano
Luis Serrano
José GarcíaJosé García
José García
The ISO/IEEE 11073 (x73) family of standards is a reference frame for medical device interoperability. A draft for an ECG device specialization (ISO/IEEE 11073-10406-d02) has already been presented to the Personal Health Device (PHD) Working Group, and the Standard Communications Protocol for Computer-Assisted ElectroCardioGraphy (SCP-ECG) Standard for short-term diagnostic ECGs (EN1064:2005+A1:2007) has recently been approved as part of the x73 family (ISO 11073-91064:2009). These factors suggest the coordinated use of these two standards in foreseeable telecardiology environments, and hence the need to harmonize them. Such harmonization is the subject of this paper. Thus, a mapping of the mandatory attributes defined in the second draft of the ISO/IEEE 11073-10406-d02 and the minimum SCP-ECG fields is presented, and various other capabilities of the SCP-ECG Standard (such as the messaging part) are also analyzed from an x73-PHD point of view. As a result, this paper addresses and analyzes the implications of some inconsistencies in the coordinated use of these two standards. Finally, a proof-of-concept implementation of the draft x73-PHD ECG device specialization is presented, along with the conversion from x73-PHD to SCP-ECG. This paper, therefore, provides recommendations for future implementations of telecardiology systems that are compliant with both x73-PHD and SCP-ECG.

7 July 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Jesús TrigoJesús Trigo
Jesús Trigo
Hicham KlainaHicham Klaina
Hicham Klaina
Imanol Picallo GuembeImanol Picallo Guembe
Imanol Picallo Guembe
Peio Lopez-IturriPeio Lopez-Iturri
Peio Lopez-Iturri
Jose Javier AstrainJose Javier Astrain
Jose Javier Astrain
LSLuis Serrano-Arriezu
Luis Serrano-Arriezu
Patients admitted to Intensive Care Units (ICU) are transported from and to other units. Knowing their location is strategic for a sound planning of intra-hospital transports as well as resources management. This is even more crucial in big hospital complexes, comprised of several buildings often connected through tunnels. In this work, a patient tracking application in a multi-building, tunnel-connected hospital complex (the Hospital Complex of Navarre) is presented. The system leverages Internet of Medical Things (IoMT) communication technologies, such as Long Range Wide-Area Network (LoRaWAN) and Near Field Communication (NFC). The locations of the LoRaWAN nodes were selected based on several factors, including the situation of the tunnels, buildings services and medical equipment and a literature review on intra-hospital ICU patients' trips. The possible locations of the LoRaWAN gateways were selected based on 3D Ray Launching Simulations, in order to obtain accurate characterization. Once the locations were set, a LoRaWAN radio coverage studio was performed. The main conclusion drawn is that just one LoRaWAN gateway would be enough to cover all overground LoRaWAN nodes deployed. A second one would be required for underground coverage. In addition, a remote, private cloud infrastructure together with a mobile application was created to manage the information generated. On-field tests were performed to assess the technical feasibility of the system. The application provides with on-demand ICU patients' movement flow around the complex. Although designed for the ICU-admitted patients' context, the system could be easily extrapolated to other use cases.

29 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Peio Lopez-IturriPeio Lopez-Iturri
Peio Lopez-Iturri
EAErik Aguirre
Erik Aguirre
Jesús TrigoJesús Trigo
Jesús Trigo
Jose Javier AstrainJose Javier Astrain
Jose Javier Astrain
Leyre AzpilicuetaLeyre Azpilicueta
Leyre Azpilicueta
Francisco FalconeFrancisco Falcone
Francisco Falcone
In the context of hospital management and operation, Intensive Care Units (ICU) are one of the most challenging in terms of time responsiveness and criticality, in which adequate resource management and signal processing play a key role in overall system performance. In this work, a context aware Intensive Care Unit is implemented and analyzed to provide scalable signal acquisition capabilities, as well as to provide tracking and access control. Wireless channel analysis is performed by means of hybrid optimized 3D Ray Launching deterministic simulation to assess potential interference impact as well as to provide required coverage/capacity thresholds for employed transceivers. Wireless system operation within the ICU scenario, considering conventional transceiver operation, is feasible in terms of quality of service for the complete scenario. Extensive measurements of overall interference levels have also been carried out, enabling subsequent adequate coverage/capacity estimations, for a set of Zigbee based nodes. Real system operation has been tested, with ad-hoc designed Zigbee wireless motes, employing lightweight communication protocols to minimize energy and bandwidth usage. An ICU information gathering application and software architecture for Visitor Access Control has been implemented, providing monitoring of the Boxes external doors and the identification of visitors via a RFID system. The results enable a solution to provide ICU access control and tracking capabilities previously not exploited, providing a step forward in the implementation of a Smart Health framework.