Javier Marcos González-Costas

Mr. Javier Marcos González-Costas

Department of Analytical and Food Chemistry, Universidade de Vigo, Vigo, Galicia, Spain
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 February 2014 in Analytica Chimica Acta
Verified
Journal Article
Closed access
MRMónica Revenga-Parra
Mónica Revenga-Parra
TGTania García-Mendiola
Tania García-Mendiola
Javier Marcos González-CostasJavier Marcos González-Costas
Javier Marcos González-Costas
Elisa González-RomeroElisa González-Romero
Elisa González-Romero
AMA. García Marín
A. García Marín
Encarnacion LorenzoEncarnacion Lorenzo
Encarnacion Lorenzo

1 November 2020 in Science of The Total Environment
Verified
Journal Article
Closed access
Javier Marcos González-CostasJavier Marcos González-Costas
Javier Marcos González-Costas
SGSiria Gómez-Fernández
Siria Gómez-Fernández
JGJosefa García
Josefa García
Elisa González-RomeroElisa González-Romero
Elisa González-Romero

18 April 2012 in Journal of Environmental Monitoring
Verified
Journal Article
Closed access
PDF file
SMSihem Mbarek
Sihem Mbarek
TSTounes Saidi
Tounes Saidi
Javier Marcos González-CostasJavier Marcos González-Costas
Javier Marcos González-Costas
Elisa González-RomeroElisa González-Romero
Elisa González-Romero
RCRafika Ben Chaouacha Chekir
Rafika Ben Chaouacha Chekir
Contamination by cadmium in the environment is of great concern because of its toxicity and threats to human and animal health. The current study was conducted to investigate the effects of a cadmium contaminated diet on the osmoregulation and urine concentration mechanisms of the semi-desert rodent Meriones shawi and eventual accumulation of this metal in vital organs such as the kidneys, which are directly implicated in water regulation. Originally, we used Differential Pulse Anodic Stripping Voltammetry (DPASV) to avoid the matrix interference due to the highly organic content in the biological samples. Our results show that Meriones shawi successfully maintained a homeostasis state and presented a special adaptation to regulate urine volume during cadmium exposure by decreasing diuresis and increasing urinary osmolality. The plasma osmolality and hematocrit remained constant throughout the experiment. The stripping signals of cadmium are linear up to 0.3–100 μg L−1 range, with a detection limit of 0.28 μg L−1. The DPASV technique was useful for easy, fast, selective and sensitive determination of Cd, which permits working at cellular concentration. This gives us more information about the chemical form in which Cd is introduced into the organ, as well as the intracellular Cd quantities. This study has potential importance if this valuable novel animal model, imitating human and animal environmental chronic exposure to Cd, could serve as an appropriate terrestrial biomonitor for Cd contaminated sites. These results are encouraging in the context of developing a low-cost and fast technology for the detection of pollutants and for studying the impairment caused by their effects.

11 April 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Javier Marcos González-CostasJavier Marcos González-Costas
Javier Marcos González-Costas
SCSara Caruncho-Pérez
Sara Caruncho-Pérez
Elisa González-RomeroElisa González-Romero
Elisa González-Romero
This study describes the development of catalytic surface immobilizing dopamine via cross-linking or tyrosinase through covalent bonds on an electrografted screen-printed carbon electrode with a 4-nitrobenzenediazonium ion. A simple electrochemical reduction approach was used to covalently graft aryldiazonium ions onto the surface of commercial electrodes. After functionalization with aminophenyl groups, dopamine, an important neurotransmitter, was immobilized by imine bond formation using glutaraldehyde as a bifunctional cross-linking molecule. The presence of immobilized dopamine was confirmed by cyclic voltammetry following the electrochemical response of the hydroquinone/quinone redox process from catechol functionalities on the surface, which are responsible for the catalytic activity. In addition, the surface was also characterized by cyclic voltammetry using the redox probe, [Fe(CN)6]3−/4−, obtaining a signal approximately 14 times higher than that of a bare electrode, achieving a dynamic concentration range spanning three orders of magnitude. Remarkable sensitivity was also obtained by combining the electrografting, in situ diazotation, to generate grafted aryl diazonium ions on the surface, and coupling reaction to anchor the tyrosinase enzyme to the electrode surface. The response of the TYR-biosensor towards catechol, using the redox probe as mediator, was 10 times higher than that obtained with the dopamine modified catalytic surface. These modified surfaces offer promising alternatives for the voltammetric quantification of catechol in environmental fields.

21 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Javier Marcos González-CostasJavier Marcos González-Costas
Javier Marcos González-Costas
SCSara Caruncho-Pérez
Sara Caruncho-Pérez
Elisa González-RomeroElisa González-Romero
Elisa González-Romero
The research work presented here describes the development of catalytic surfaces immobilizing dopamine via cross-linking or tyrosinase via covalent bond on an electrografted screen-printed carbon electrode with a 4-nitrobenzenediazonium ion. A simple electrochemical reduction approach was used to graft aryldiazonium ions onto commercial electrodes, resulting in the formation of a covalently bonded aromatic layer on the electrode surface. After functionalization with aminophenyl groups, dopamine, an important neurotransmitter, was immobilized by imine bond formation using glutaraldehyde as a bifunctional cross-linking molecule. The presence of immobilized dopamine was confirmed by cyclic voltammetry following the electrochemical response of the hydroquinone/quinone redox process from catechol functionalities on the surface, which are responsible for the catalytic activity. In addition, the surface was also characterized by cyclic voltammetry using the redox probe, [Fe(CN)6]3-/4-, obtaining a signal on this catalytic DA-biosensor about 14 times higher than that of a bare electrode, achieving a dynamic concentration range spanning three orders of magnitude. Remarkable sensitivity was also obtained by combining the electrografting, in situ diazotation to generate grafted aryl diazonium ions on the surface and coupling reaction to anchor the tyrosinase enzyme to the electrode surface. The response of the TYR-biosensor towards catechol, using the redox probe as mediator, was 10 times higher than that obtained with the dopamine modified catalytic surface. These modified surfaces offer promising alternatives for the voltammetric quantification of catechol in environmental fields.