Jingxuan Song

Dr. Jingxuan Song


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2022 in Research on Chemical Intermediates
Verified
Journal Article
Closed access
PDF file
FLFangcheng Lv
Fangcheng Lv
XLXiuquan Lu
Xiuquan Lu
JSJingxuan Song
Jingxuan Song
MZMeiying Zhu
Meiying Zhu
SWShenghui WANG
Shenghui WANG
XCXiaobin Chang
Xiaobin Chang

14 August 2023 in Composites Science and Technology
Verified
Journal Article
Closed access
JSJingxuan Song
Jingxuan Song
FLFangcheng Lü
Fangcheng Lü
HRHaoou Ruan
Haoou Ruan
MZMeiying Zhu
Meiying Zhu
QXQing Xie
Qing Xie

14 July 2022 in Polymer Engineering & Science
Verified
Journal Article
Closed access
LFLü Fang‐Cheng
Lü Fang‐Cheng
ZMZhu Mei‐Ying
Zhu Mei‐Ying
JSJingxuan Song
Jingxuan Song
LXLu Xiu‐Quan
Lu Xiu‐Quan
RHRuan Hao‐Ou
Ruan Hao‐Ou
CXChang Xiao‐Bin
Chang Xiao‐Bin

23 December 2022 in High Voltage
Verified
Journal Article
Open access
HRHaoou Ruan
Haoou Ruan
QXQing Xie
Qing Xie
JSJingxuan Song
Jingxuan Song
SWShenghui Wang
Shenghui Wang
XCXiaobin Chang
Xiaobin Chang
FLFangcheng Lü
Fangcheng Lü
Organophilic groups of coupling agents can be the key factor for the electrical performance of Boron Nitride (BN)/meta‐aramid composite paper. In this article, four types of triethoxy‐silane coupling agents with different organophilic groups, including mercapto‐propyl (MP), glycidylether‐propyl (GP), amino‐propyl (AP) and trideca‐fluoro‐octyl (TFO) were studied. The structural and electrical properties of modified papers were compared, and the molecular simulation was conducted to reveal the interface interaction of modified BN and aramid. The results show that AP, GP and MP follow the same mechanism, improving the electrical performance by modifying the interface stability and paper structure, and the ranks of improving effects are AP, MP and GP. While, TFO mainly relies on the fluorine components to implement the electrical reinforcement, which compensates for the shortcoming in the paper structure. By choosing TFO and filler content of 15 wt%, the optimal breakdown strength of the paper can be increased to 28.17 kV/mm, 1.8 times that of the paper doped with the hydroxylated BN.

27 March 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Haoou RUANHaoou RUAN
Haoou RUAN
SHShi-Xun Hu
Shi-Xun Hu
JSJingxuan Song
Jingxuan Song
XLXiong Liu
Xiong Liu
This study investigates the impact of interface defects on the electrical performance of epoxy-impregnated aramid papers. Various composites with different degrees of defects were prepared and analyzed for their structural, mechanical, partial discharge, and insulation performance. The results demonstrate the widespread presence of void defects in the composites, negatively affecting paper compactness, mechanical properties, initial discharge voltage, and leading to significant gas gap discharge phenomena. In terms of insulation performance, composites with severe defects exhibit a 40-fold increase in low-frequency dielectric loss, a 16-fold increase in electrical conductivity, and up to a 64% reduction in breakdown field strength, along with noticeable shallowing of charge traps. Phase field modeling of electro-thermal breakdown reveals that void-type defects guide discharge trajectories, causing lateral damage diffusion, localized overheating, and severe electric field distortion, ultimately endangering the voltage resistance. This study provides the research support for the application of aramid paper as a matrix for a novel epoxy-impregnated insulating paper.

29 August 2019 in IEEE Access
Verified
Journal Article
Open access
FLFangcheng Lv
Fangcheng Lv
JSJingxuan Song
Jingxuan Song
WPWang Ping
Wang Ping
HRHaoou Ruan
Haoou Ruan
JGJianghai Geng
Jianghai Geng
The morphologies and velocity of ionic wind induced by direct-current (DC) corona discharge were experimentally measured. DC voltage was applied to short air gaps of high-voltage electrode–needle electrode and grounding electrode–net electrode to generate coronas, so as to allow the generation of ionic wind induced by corona discharge. The purpose of the study is to optimise the multi-needle-to-net electrode structure to improve the velocity of the ionic wind and keep it in a relatively stable state. For this purpose, the influences of various parameters on the velocity of the ionic wind were explored. The research results showed that the side length of meshes and the distribution mode of needles significantly affected the velocity of the ionic wind. The maximum velocity of the ionic wind, when the side length of meshes was 0.85 mm was 3 and 1.28 times those when the side lengths of the meshes were 2 and 0.425 mm, respectively. This indicated that there was an optimal side length that can maximise the velocity of the ionic wind. Increasing the number of needles and optimising the distribution mode of needles can effectively improve the velocity, that is, the improvement of the number and distribution uniformity of needles was conducive to increase the velocity of the ionic wind. Increasing the voltage amplitude can increase the velocity of the ionic wind, however, it was possible that noise was significant and in this case, the corresponding voltage cannot be considered as the working voltage of the ionic wind generator.