Shenghui WANG

Mr. Shenghui WANG

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2022 in Polymers
Verified
Journal Article
Open access
PDF file
SWShenghui WANG
Shenghui WANG
MHMengchao Hou
Mengchao Hou
KMKang Ma
Kang Ma
ZLZhiwei Li
Zhiwei Li
伟辛伟峰 辛
伟峰 辛
NLNan Li
Nan Li
In order to study the performance variation characteristics of silicone rubber and fluorinated silicone rubber at extremely cold temperatures, two type samples were frozen for 0, 150, 300, 450, 600, 750, 900 and 1050 h in a low-temperature test chamber with a constant temperature of −50 °C. After the samples reached a certain freezing time, they were taken out and placed at room temperature for 2 h, then the breakdown voltage, mechanical tensile properties, and hardness and surface morphology were measured, and the mechanism was analyzed. The breakdown voltage, maximum tensile force, and tensile strength of the two type samples increased with freezing time. The elongation at break decreased with freezing time, but the hardness of the two materials changed little. Microcracks appeared on the surface of the samples at about 300 h and some tiny pore and holes appeared at 750 h. The length and depth of the microcracks gradually developed with freezing time. The comparative test results of the two materials showed that the performance of fluorinated silicone rubber was better than that of silicone rubber, which indicates that fluorinated silicone rubber is more stable for some applications in extremely cold environments.

3 September 2022 in Research on Chemical Intermediates
Verified
Journal Article
Closed access
PDF file
FLFangcheng Lv
Fangcheng Lv
XLXiuquan Lu
Xiuquan Lu
JSJingxuan Song
Jingxuan Song
MZMeiying Zhu
Meiying Zhu
SWShenghui WANG
Shenghui WANG
XCXiaobin Chang
Xiaobin Chang

14 July 2022 in Polymer Engineering & Science
Verified
Journal Article
Closed access
LFLü Fang‐Cheng
Lü Fang‐Cheng
ZMZhu Mei‐Ying
Zhu Mei‐Ying
JSJingxuan Song
Jingxuan Song
LXLu Xiu‐Quan
Lu Xiu‐Quan
RHRuan Hao‐Ou
Ruan Hao‐Ou
CXChang Xiao‐Bin
Chang Xiao‐Bin

16 April 2022 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
WZWei Zhang
Wei Zhang
ZMZhichao Ma
Zhichao Ma
DLDongni Liu
Dongni Liu
SWShenghui WANG
Shenghui WANG
HZHongwei Zhao
Hongwei Zhao
LRLuquan Ren
Luquan Ren

1 November 2021 in Energy Reports
Verified
Journal Article
Open access
YDYujian Ding
Yujian Ding
Jun ZhouJun Zhou
Jun Zhou
CLChangkan Li
Changkan Li
Guilin LiuGuilin Liu
Guilin Liu
HWHuapeng Wang
Huapeng Wang
SWShenghui WANG
Shenghui WANG

11 July 2022 in Coatings
Verified
Journal Article
Open access
PDF file
SWShenghui WANG
Shenghui WANG
HLHuaqi Liu
Huaqi Liu
KMKang Ma
Kang Ma
QOQi Ou
Qi Ou
HGHui Geng
Hui Geng
FLFangcheng Lv
Fangcheng Lv
Metal particle contamination is an important reason for insulation failure of gas-insulated transmission lines (GILs). Particle trap is the common method for particle suppression. At present, research on the motion characteristics of metal particles near a particle trap and the optimization of trap parameters under AC voltage is insufficient. Based on that, firstly, a dynamic model of metal particles under AC voltage was established, and the motion characteristics of particles in front of the trap were studied, combined with experiments. Then, the influence of trap parameters on the capture effect was analyzed, and the optimization of the trap was realized by simulation. The results showed that, under AC voltage, the randomness of metal particle movement was strong, and the activity was low. The particles mainly moved away from the trap. Among the particles moving towards the trap, some stayed in front of the trap, and some fell into the trap from above. The thickness and height of the trap were the key parameters affecting the capture effect, and with the increase in height and thickness, the capture rate showed a trend of increasing first and then decreasing. The above conclusions can provide a reference for the optimization of a metal particle trap under AC voltage in engineering.