Juliana Manrique Cordoba

Ms. Juliana Manrique Cordoba

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DZDavid Zambrana-Vinaroz
David Zambrana-Vinaroz
Jose Maria Vicente-SamperJose Maria Vicente-Samper
Jose Maria Vicente-Samper
Juliana Manrique CordobaJuliana Manrique Cordoba
Juliana Manrique Cordoba
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
Epileptic seizures have a great impact on the quality of life of people who suffer from them and further limit their independence. For this reason, a device that would be able to monitor patients’ health status and warn them for a possible epileptic seizure would improve their quality of life. With this aim, this article proposes the first seizure predictive model based on Ear EEG, ECG and PPG signals obtained by means of a device that can be used in a static and outpatient setting. This device has been tested with epileptic people in a clinical environment. By processing these data and using supervised machine learning techniques, different predictive models capable of classifying the state of the epileptic person into normal, pre-seizure and seizure have been developed. Subsequently, a reduced model based on Boosted Trees has been validated, obtaining a prediction accuracy of 91.5% and a sensitivity of 85.4%. Thus, based on the accuracy of the predictive model obtained, it can potentially serve as a support tool to determine the status epilepticus and prevent a seizure, thereby improving the quality of life of these people.

28 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Juliana Manrique CordobaJuliana Manrique Cordoba
Juliana Manrique Cordoba
MLMiguel Ángel de la Casa Lillo
Miguel Ángel de la Casa Lillo
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
This paper presents an n-dimensional reduction algorithm for Learning from Demonstration (LfD) for robotic path planning, addressing the complexity of high-dimensional data. The method extends the Douglas–Peucker algorithm by incorporating velocity and orientation alongside position, enabling more precise trajectory simplification. A magnitude-based normalization process preserves proportional relationships across dimensions, and the reduced dataset is used to train Hidden Markov Models (HMMs), where continuous trajectories are discretized into identifier sequences. The algorithm is evaluated in 2D and 3D environments with datasets combining position and velocity. The results show that incorporating additional dimensions significantly enhances trajectory simplification while preserving key information. Additionally, the study highlights the importance of selecting appropriate encoding parameters to achieve optimal resolution. The HMM-based models generated new trajectories that retained the patterns of the original demonstrations, demonstrating the algorithm’s capacity to generalize learned behaviors for trajectory learning in high-dimensional spaces.

16 May 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
Juan David Romero AnteJuan David Romero Ante
Juan David Romero Ante
ECEsther Chicharro-Luna
Esther Chicharro-Luna
Juliana Manrique CordobaJuliana Manrique Cordoba
Juliana Manrique Cordoba
Jose Maria Vicente-SamperJose Maria Vicente-Samper
Jose Maria Vicente-Samper
AGAlba Gracia-Sánchez
Alba Gracia-Sánchez
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
Peripheral artery disease (PAD) is a common circulatory disorder characterized by the accumulation of fats, cholesterol, and other substances in the arteries that restrict blood flow to the extremities, especially the legs. The ankle brachial index (ABI) is a highly reliable and valid non-invasive test for diagnosing PAD. However, the traditional method has limitations. These include the time required, the need for Doppler equipment, the training of clinical staff, and patient discomfort. PWV refers to the speed at which an arterial pressure wave propagates along the arteries, and this speed is conditioned by arterial elasticity and stiffness. To address these limitations, we have developed a system that uses electrocardiogram (ECG) and photoplethysmography (PPG) signals to calculate pulse wave velocity (PWV). We propose determining the ABI based on this calculation. Validation was performed on 22 diabetic patients, and the results demonstrate the accuracy of the system, maintaining a margin of ±0.1 compared with the traditional method. This confirms the correlation between PWV and ABI and positions this technique as a promising alternative to overcome some of the limitations of the conventional method.

13 July 2023 in Revista Iberoamericana de Automática e Informática Industrial
Verified
Journal Article
Open access
PDF file
Juan Sebastian Montenegro BravoJuan Sebastian Montenegro Bravo
Juan Sebastian Montenegro Bravo
JRJuan David Ruiz-Flórez
Juan David Ruiz-Flórez
Juan David Romero AnteJuan David Romero Ante
Juan David Romero Ante
Juliana Manrique CordobaJuliana Manrique Cordoba
Juliana Manrique Cordoba
Andrés Vivas Andrés Vivas
Andrés Vivas
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
Las operaciones pick-and-place son las más frecuentes en aplicaciones robóticas, y muchas veces su diseño incluye la presencia de obstáculos. En este trabajo se presenta la construcción de una plataforma software que permite la manipulación de un robot colaborativo UR3e mediante la generación de trayectorias 3D facilmente definidas por el usuario, además de una de pinza blanda capaz de sujetar objetos con diferentes geometrías. Para ello, se detalla el desarrollo de una interfaz gráfica en Unity, así como la incorporación del gemelo digital del robot UR3e. Del mismo modo, se exponen los diferentes módulos que permiten la comunicación de la plataforma con el manipulador a través de ROS. Los resultados muestran la creación de rutas adaptadas por el usuario ante diferentes casos en zonas de colisión y la disposición de la pinza para sujetar diferentes objetos. También se compara el error deprecisión entre los datos enviados respecto a los que se reciben desde el robot durante el seguimiento de trayectorias definidas por el usuario.

7 April 2020 in Revista Iberoamericana de Automática e Informática Industrial
Verified
Journal Article
Open access
PDF file
Juliana Manrique CordobaJuliana Manrique Cordoba
Juliana Manrique Cordoba
Juan David Romero AnteJuan David Romero Ante
Juan David Romero Ante
AVA. Vivas
A. Vivas
JVJ.M. Vicente
J.M. Vicente
JSJ. M. Sabater-Navarro
J. M. Sabater-Navarro
La diabetes tipo 1 es una afección en la cual el páncreas pierde su capacidad de producir suficiente insulina, incrementando significativamente la concentración de glucosa en la sangre. En el presente trabajo se presenta el diseño de un modelo matemático de las dinámicas glucosa-insulina de un paciente con diabetes tipo 1, el cual contempla el aporte a la concentración de glucosa en la sangre por parte de la ingesta de carbohidratos, grasas y proteínas. El modelo incluye las dinámicas de absorción de 5 tipos de insulina, diferentes métodos de administración de la misma, y la variación de la sensibilidad a la insulina durante el día. Se integró el modelo a un algoritmo de regulación de insulina en lazo cerrado, con el fin de evaluar el desempeño del modelo y la eficacia de los tratamientos en lazo cerrado, en comparación con las terapias en lazo abierto. Los resultados muestran la respuesta del modelo ante distintas situaciones de un paciente real, y pruebas de funcionamiento del controlador.

28 June 2023 in Revista Iberoamericana de Automática e Informática Industrial
Verified
Journal Article
Open access
PDF file
Juliana Manrique CordobaJuliana Manrique Cordoba
Juliana Manrique Cordoba
Juan David Romero AnteJuan David Romero Ante
Juan David Romero Ante
Jose Maria Vicente-SamperJose Maria Vicente-Samper
Jose Maria Vicente-Samper
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
Diversos estudios han demostrado que la sensibilidad a la insulina presenta fluctuaciones durante la fase lútea y folicular del ciclo menstrual que pueden generar alteraciones en el comportamiento del nivel de glucosa. Diversos estudios han demostrado que la sensibilidad a la insulina presenta fluctuaciones durante la fase lútea y folicular del ciclo menstrual que pueden generar alteraciones en el comportamiento del nivel de glucosa. Conocer la relación entre las fases del ciclo menstrual y la resistencia a la insulina es un objetivo de salud personalizada, enfocada a la mejora de la calidad de vida. En esta investigación se propone una modificación al modelo matemático desarrollado por Dalla Man et al. (Dalla Man, C., Rizza, R. A., & Cobelli, C., 2007) para incluir las diferentes etapas del ciclo menstrual sobre el comportamiento del nivel de glucosa en la sangre, teniendo en cuenta cambios en la sensibilidad a la insulina y el valor basal de glucosa en la sangre. Para comprobar el comportamiento del nivel de glucosa durante el ciclo menstrual descrito en la literatura se realizó una prueba de tolerancia a la glucosa en una individua sana regularmente menstruante y se comparó con resultados de simulación in-vitro. Los resultados permiten observar comportamiento descrito en el modelo propuesto al relacionar las diferentes fases del ciclo menstrual y la resistencia a la insulina.