João P. Mendes

Dr. João P. Mendes

University of Porto, Porto, Portugal
+2
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PSPaulo Santos
Paulo Santos
JMJoão P. Mendes
João P. Mendes
BDBernardo Dias
Bernardo Dias
JPJorge Pérez-Juste
Jorge Pérez-Juste
Jose Manuel M. M. de AlmeidaJose Manuel M. M. de Almeida
Jose Manuel M. M. de Almeida
Luís C. C. CoelhoLuís C. C. Coelho
Luís C. C. Coelho
Biochemical–chemical sensing with plasmonic sensors is widely performed by tracking the responses of surface plasmonic resonance peaks to changes in the medium. Interestingly, consistent sensitivity and resolution improvements have been demonstrated for gold nanoparticles by analyzing other spectral features, such as spectral inflection points or peak curvatures. Nevertheless, such studies were only conducted on planar platforms and were restricted to gold nanoparticles. In this work, such methodologies are explored and expanded to plasmonic optical fibers. Thus, we study—experimentally and theoretically—the optical responses of optical fiber-doped gold or silver nanospheres and optical fibers coated with continuous gold or silver thin films. Both experimental and numerical results are analyzed with differentiation methods, using total variation regularization to effectively minimize noise amplification propagation. Consistent resolution improvements of up to 2.2× for both types of plasmonic fibers are found, demonstrating that deploying such analysis with any plasmonic optical fiber sensors can lead to sensing resolution improvements.

19 April 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Francesco ArcadioFrancesco Arcadio
Francesco Arcadio
Mimimorena SeggioMimimorena Seggio
Mimimorena Seggio
DPDomenico Del Prete
Domenico Del Prete
GBGionatan Buonanno
Gionatan Buonanno
JMJoão P. Mendes
João P. Mendes
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
Plasmonic bio/chemical sensing based on optical fibers combined with molecularly imprinted nanoparticles (nanoMIPs), which are polymeric receptors prepared by a template-assisted synthesis, has been demonstrated as a powerful method to attain ultra-low detection limits, particularly when exploiting soft nanoMIPs, which are known to deform upon analyte binding. This work presents the development of a surface plasmon resonance (SPR) sensor in silica light-diffusing fibers (LDFs) functionalized with a specific nanoMIP receptor, entailed for the recognition of the protein human serum transferrin (HTR). Despite their great versatility, to date only SPR-LFDs functionalized with antibodies have been reported. Here, the innovative combination of an SPR-LFD platform and nanoMIPs led to the development of a sensor with an ultra-low limit of detection (LOD), equal to about 4 fM, and selective for its target analyte HTR. It is worth noting that the SPR-LDF-nanoMIP sensor was mounted within a specially designed 3D-printed holder yielding a measurement cell suitable for a rapid and reliable setup, and easy for the scaling up of the measurements. Moreover, the fabrication process to realize the SPR platform is minimal, requiring only a metal deposition step.

22 January 2022 in Polymers
Verified
Journal Article
Open access
PDF file
BDBernardo Dias
Bernardo Dias
João P. M. CarvalhoJoão P. M. Carvalho
João P. M. Carvalho
JMJoão P. Mendes
João P. Mendes
Jose Manuel M. M. de AlmeidaJose Manuel M. M. de Almeida
Jose Manuel M. M. de Almeida
Luís C. C. CoelhoLuís C. C. Coelho
Luís C. C. Coelho
Relative humidity (RH) monitorization is of extreme importance on scientific and industrial applications, and optical fiber sensors (OFS) may provide adequate solutions. Typically, these kinds of sensors depend on the usage of humidity responsive polymers, thus creating the need for the characterization of the optical and expansion properties of these materials. Four different polymers, namely poly(vinyl alcohol), poly(ethylene glycol), Hydromed™ D4 and microbiology agar were characterized and tested using two types of optical sensors. First, optical fiber Fabry–Perot (FP) tips were made, which allow the dynamical measurement of the polymers’ response to RH variations, in particular of refractive index, film thickness, and critical deliquescence RH. Using both FP tips and Long-Period fiber gratings, the polymers were then tested as RH sensors, allowing a comparison between the different polymers and the different OFS. For the case of the FP sensors, the PEG tips displayed excellent sensitivity above 80%RH, outperforming the other polymers. In the case of LPFGs, the 10% (wt/wt) PVA one displayed excellent sensitivity in a larger working range (60 to 100%RH), showing a valid alternative to lower RH environment sensing.

22 January 2017 in Molecular Crystals and Liquid Crystals
Verified
Journal Article
Open access
JMJoão P. Mendes
João P. Mendes
JEJosé M.S.S. Esperança
José M.S.S. Esperança
MMM. J. Medeiros
M. J. Medeiros
XXXxx Xxx
Xxx Xxx
Maria Manuela SilvaMaria Manuela Silva
Maria Manuela Silva
New polymer electrolytes (PEs), potentially interesting for solid-state electrochemical devices applications, were synthesized by a solvent casting method using pectin and ionic liquid (IL) N,N,N-trimethyl-N-(2-hydroxyethyl)ammonium bis(trifluoromethylsulfonyl)imide ([N1 1 1 2(OH)] [NTf2]. The resulting electrolytes besides being moderately homogenous and thermally stable below 155°C, they also exhibited good mechanical properties. The SPE membranes were analyzed by differential scanning calorimetry (DSC), X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM), and complex impedance spectroscopy.

4 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JPJosé Miguel Pereira
José Miguel Pereira
JMJoão P. Mendes
João P. Mendes
BDBernardo Dias
Bernardo Dias
Jose Manuel M. M. de AlmeidaJose Manuel M. M. de Almeida
Jose Manuel M. M. de Almeida
Luís C. C. CoelhoLuís C. C. Coelho
Luís C. C. Coelho
An optical fiber pH sensor based on a long-period fiber grating (LPFG) is reported. Two oppositely charged polymers, polyethylenimine (PEI) and polyacrylic acid (PAA), were alternately deposited on the sensing structure through a layer-by-layer (LbL) electrostatic self-assembly technique. Since the polymers are pH sensitive, their refractive index (RI) varies when the pH of the solution changes due to swelling/deswelling phenomena. The fabricated multilayer coating retained a similar property, enabling its use in pH-sensing applications. The pH of the PAA dipping solution was tuned so that a coated LPFG achieved a pH sensitivity of (6.3 ± 0.2) nm/pH in the 5.92–9.23 pH range. Only two bilayers of PEI/PAA were used as an overlay, which reduces the fabrication time and increases the reproducibility of the sensor, and its reversibility and repeatability were demonstrated by tracking the resonance band position throughout multiple cycles between different pH solutions. With simulation work and experimental results from a low-finesse Fabry–Perot (FP) cavity on a fiber tip, the coating properties were estimated. When saturated at low pH, it has a thickness of 200 nm and 1.53 ± 0.01 RI, expanding up to 310 nm with a 1.35 ± 0.01 RI at higher pH values, mostly due to the structural changes in the PAA.

13 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JMJoão P. Mendes
João P. Mendes
Luís C. C. CoelhoLuís C. C. Coelho
Luís C. C. Coelho
BKB. Kovacs
B. Kovacs
Jose Manuel M. M. de AlmeidaJose Manuel M. M. de Almeida
Jose Manuel M. M. de Almeida
Carlos PereiraCarlos Pereira
Carlos Pereira
MBM.T. Borges
M.T. Borges
A sensing configuration for the real-time monitoring, detection, and quantification of dissolved carbon dioxide (dCO2) was developed for aquaculture and other applications in freshwater and saline water. A chemical sensing membrane, based on a colorimetric indicator, is combined with multimode optical fiber and a dual wavelength light-emitting diode (LED) to measure the dCO2-induced absorbance changes in a self-referenced ratiometric scheme. The detection and processing were achieved with an embeded solution having a mini spectrometer and microcontroller. For optrode calibration, chemical standard solutions using sodium carbonate in acid media were used. Preliminary results in a laboratory environment showed sensitivity for small added amounts of CO2 (0.25 mg·L−1). Accuracy and response time were not affected by the type of solution, while precision was affected by salinity. Calibration in freshwater showed a limit of detection (LOD) and a limit of quantification (LOQ) of 1.23 and 1.87 mg·L−1, respectively. Results in saline water (2.5%) showed a LOD and LOQ of 1.05 and 1.16 mg·L−1, respectively. Generally, performance was improved when moving from fresh to saline water. Studies on the dynamics of dissolved CO2 in a recirculating shallow raceway system (SRS+RAS) prototype showed higher precision than the tested commercial sensor. The new sensor is a compact and robust device, and unlike other sensors used in aquaculture, stirring is not required for correct and fast detection. Tests performed showed that this new sensor has a fast accurate detection as well as a strong potential for assessing dCO2 dynamics in aquaculture applications.