Using a set of model equations of state satisfying the latest constraints from both terrestrial nuclear experiments and astrophysical observations, as well as state-of-the-art nuclear many-body calculations of the pure neutron matter equation of state, the tidal polarizability of canonical neutron stars in coalescing binaries is found to be a very sensitive probe of the high-density behavior of nuclear symmetry energy, which is among the most uncertain properties of dense neutron-rich nucleonic matter. Moreover, it changes less than by varying various properties of symmetric nuclear matter and symmetry energy around the saturation density within their respective ranges of remaining uncertainty.
The motivation for using artificial neural networks in this study stems from their computational efficiency and ability to model complex, high-level abstractions. Deep learning models were utilized to predict the structural responses of reinforced concrete (RC) buildings subjected to earthquakes. For this aim, the dataset for training and evaluation was derived from complex computational dynamic analyses, which involved scaling real ground motion records at different intensity levels (spectral acceleration Sa(T1) and the recently proposed INp). The results, specifically the maximum interstory drifts, were characterized for the output neurons in terms of their corresponding statistical parameters: mean, median, and standard deviation; while two input variables (fundamental period and earthquake intensity) were used in the neural networks to represent buildings and seismic risk. To validate deep learning as a robust tool for seismic predesign and rapid estimation, a prediction model was developed to assess the seismic performance of a complex RC building with buckling restrained braces (RC-BRBs). Additionally, other deep learning models were explored to predict ductility and hysteretic energy in nonlinear single degree of freedom (SDOF) systems. The findings demonstrated that increasing the number of hidden layers generally reduces prediction error, although an excessive number can lead to overfitting.
Although some studies have been conducted to compute fragility surfaces of buildings using vector-valued seismic intensity measures (IMs), in all the cases, the first component of the vector usually is the spectral acceleration at first mode of vibration of the structure Sa(T1). In this study, fragility surfaces of three reinforced concrete buildings (RCB) subjected to narrow-band ground motions obtained from soft soil of Mexico City are computed considering vector-valued IMs based not only on Sa(T1), but also the velocity V(T1), pseudo-velocity Sv(T1), and normalized input energy by the mass EI/m(T1) as the first component. As second component of the vector-valued IMs, the Peak Ground Acceleration (PGA), Peak Ground Velocity (PGV), effective duration (tD), earthquake damage potential (ID) and four Np spectral shape-based parameters obtained through spectral acceleration (NpSa), velocity (NpV), pseudo-velocity (NpSv), and input energy (NpEI) have been analyzed. In order to obtain fragility surfaces, Multinomial Logistic Regression (MLR) was applied. It is observed that those vector-valued IMs based on the spectral shape proxies were more efficient to predict the probability of failure of RCB. For this reason, it is important to consider spectral shape vector-valued IMs in order to reduce uncertainty in the structural response of buildings under earthquakes. Thus, the use of two parameters instead of a single intensity measure improves the efficiency. Moreover, the fragility surfaces can be used for the seismic risk evaluation of buildings.
In this study, the seismic responses of moment-resisting steel frames (MRSFs) with welded and post-tensioned connections under 28 artificial seismic sequences (mainshock–aftershock) are compared. For this aim, the mainshock are scaled at different ground motion intensity levels as a function of the spectral pseudo-acceleration corresponding to the fundamental period of vibration of the structure Sa(T1), whereas different intensity levels of the aftershocks are used for a percentage of the peak maximum acceleration of the mainshock. The seismic performance comparison of both structural systems is computed for the maximum, residual inter-story drift and hysteretic energy demands. The results show that post-tensioned frames significantly reduce the structural demands, especially in the case of residual inter-story drifts and hysteretic energy in comparison with moment-resisting steel frames with welded connections. The reductions in the structural response tend to be larger as the intensity of the aftershock tends to increase. Therefore, it is concluded that the use of post-tensioned connections is a great alternative to mitigate the seismic response of buildings subjected to seismic sequences.
This paper presents the design and implementation of a low-profile remote monitoring and control system for water level management in storage tanks located in rural communities. The system was developed to ensure a reliable water supply, prevent spills, reduce electrical energy consumption, and mitigate theft and vandalism risks posed by a previously installed, highly exposed commercial system. The proposed system employs LoRa technology to transmit water level data from the storage tank to a receiver located 6 km from the water well. When the water level drops below a predefined threshold, the system transmits an activation signal through the LoRa network to start the well pump and trigger tank refilling. In addition, an SMS monitoring module enables users to remotely verify water level and pump operational status at any time. System notifications and operational data are automatically delivered via SMS to predefined phone numbers, enabling continuous supervision without requiring internet connectivity. The implementation of the proposed system thus provides an efficient and reliable solution for water resource management in rural environments, ensuring continuous water availability and preventing supply shortages. LoRa communication enables robust long-range data transmission, while SMS-based monitoring offers real-time operational awareness for end users. The system was validated through field testing in a pilot rural community, demonstrating operational robustness, improved water management efficiency, and measurable positive impacts on residents’ water service continuity. The low-profile physical design significantly reduced theft and vandalism incidents reported by the local water authority. Experimental results showed an average monthly reduction of 41.2% in electrical energy consumption while maintaining high system reliability, physical security, and real-time monitoring capability.
2 September 2025 in International Journal of Disaster Risk Reduction