The theoretical operation and experimental demonstration of a Fourier transform imaging spectropolarimeter for real time measurement of the polarization state of light are presented. The spectropolarimeter uses a Wollaston prism as a birefringent interferometer and two high-order retarders to incorporate channeled polarimetry. Compared with previous instruments, the most significant advantage of the described model is that the complete wavelength-dependent polarization is acquired simultaneously along a one-dimensional spatial image by a single snapshot. Also, we show that, in this configuration, we can benefit from the advantages of the model: it is compact and robust, and the birefringent interferometer has a high throughput.
Polarization difference imaging technique can effectively solve the underwater image deterioration problem that is caused by the interaction between light and water. Therefore, it has a significant application value in detecting and recognizing underwater target. In a traditional polarization difference imaging system, the object image is carried out by the common-mode rejection of background scattering light. However, the polarization state of the background scattering light is unknown, so the polarization difference imaging is realized by the irregular mechanical rotation of the optical polarization analyzer with two orthogonal polarization orientations. Therefore, it needs more time to determine the optimum detection angle of the polarization analyzer and cannot perform real-time underwater imaging, which restricts the rapid detecting function in the process of underwater imaging. In this paper, the detection principle of underwater polarization difference imaging is considered to exploit the difference in the polarization angle between background scattering light and target light. According to Marius's law, the physical model of polarization difference imaging is that the common-mode rejection of background scattering light will be achieved when the angles between the vibration direction of background and the two orthogonal polarization orientations are 45. Because the Stokes vector can be used to express the polarization angle of light, we propose the principle and construction of a computational polarization difference imaging system for real-time underwater imaging by incorporating the Stokes vector into the established model. It replaces the mechanical rotation of the polarization analyzer in a traditional polarization difference imaging system with the information processing of the Stokes vector. The experimental results show that the proposed method not only has the same effective performance as the conventional polarization difference imaging compared with the regular imaging, but also can improve the blurred imaging performance caused by an underwater scattering effect as well as increase the underwater detection distance. This method realizes rapid underwater target detection and recognition because it saves a large amount of time compared with the traditional one. Further, if we combine this method with the current polarization imaging instruments that capture the Stokes vector instantaneously, then a real-time automatic underwater polarization imaging can improve the efficiency of the underwater target detection and recognition. These findings are helpful for designing and developing the underwater polarization difference imaging systems.
The geometrical attenuation model given by Blinn was widely used in the geometrical optics bidirectional reflectance distribution function (BRDF) models. Blinn’s geometrical attenuation model based on symmetrical V-groove assumption and ray scalar theory causes obvious inaccuracies in BRDF curves and negatives the effects of polarization. Aiming at these questions, a modified polarized geometrical attenuation model based on random surface microfacet theory is presented by combining of masking and shadowing effects and polarized effect. The p-polarized, s-polarized and unpolarized geometrical attenuation functions are given in their separate expressions and are validated with experimental data of two samples. It shows that the modified polarized geometrical attenuation function reaches better physical rationality, improves the precision of BRDF model, and widens the applications for different polarization.
As a key component of electron multiplier device, a microchannel plate (MCP) can be applied in many scientific fields. Pure aluminum oxide (Al2O3) as secondary electron emission (SEE) layer were deposited in the pores of MCP via atomic layer deposition (ALD) to overcome problems such as high dark current and low lifetime which often occur on traditional MCP. In this paper, we systematically investigate the morphology, element distribution, and structure of samples by scanning electron microscopy (SEM) and energy disperse spectroscopy (EDS), respectively. Output current of different thickness of Al2O3 was studied and an optimal thickness was found. Experimental tests show that the average gain of ALD-MCP was nearly five times better than that of traditional MCP, and the ALD-MCP showed better sensitivity and longer lifetime.